Page 261

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 231
Delay Announcement - Attendant D-114
Service Conditions (cont’d)
7. The maximum programmable channels of DAT for this feature are:
1st announcement: 5 channels
2nd announcement: 5 channels
8. When a call encounters announcement trunks all busy, the call waits in a queue until a trunk becomes
available. The latter trunk call hears ringback tone until the announcement to the former terminated call
completes.
9. When providing the...

Page 262

NEAX2400 IMX Business Features and Specifications
Page 232NDA-24221, Issue 3
D-114 Delay Announcement - Attendant
Service Conditions (cont’d)
18. When this service is allowed in system data, the ATTENDANT OVERFLOW [A-105] feature cannot be
activated.
19. When the external announcement machine is used, the announcement starts from the time when the PBX
acknowledges the announcement trunk answer, and ends at the time of the announcement trunk release.
20. When activating this feature in an FCCS network,...

Page 263

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 233
Direct Station Selection (DSS) Console D-149
D-149  Direct Station Selection (DSS) Console
General Description
A Direct Station Selection (DSS) Console may be connected to each Dterm. The DSS keys can be used as line keys
or feature keys.
Operating Procedure
Refer to the User Guide.
Service Conditions
1. The DSS console has 60 keys, each with one or two lamps.
2. The DSS console has following two operating functions:
a.)...

Page 264

NEAX2400 IMX Business Features and Specifications
Page 234NDA-24221, Issue 3
D-149 Direct Station Selection (DSS) Console
Service Conditions (cont’d)
7. The user can recognize the idle/busy status of the accommodated stations by the lamps. The left lamp (red)
lights when busy and goes out when idle and shows incoming call, hold, etc. The right lamp (green) shows
I-used, I-hold, etc.
8. The DSS console and the connected D
term may be accommodated in the different circuit card, but should
belong to the...

Page 265

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 235
Distinctive Ringing - Caller ID D-153
D-153 Distinctive Ringing - Caller ID
General Description
This feature is a part of CALLER ID service. This feature provides a distinctive ringing pattern (0, 1, 5, 6 or 7)
according to the received calling number.
Operating Procedure
No manual operation is required.
Service Conditions
1. On-off timing of Ringer Patterns 0, 1, 5, 6 and 7 can be changed using ASYD command. System data...

Page 266

NEAX2400 IMX Business Features and Specifications
Page 236NDA-24221, Issue 3
D-153 Distinctive Ringing - Caller ID
Service Conditions (cont’d)
13. Ringer patterns 2, 3 or 4 cannot be assigned for this feature. When one of those ringer patterns is assigned
from the MAT, default value “Ringer pattern 6” is automatically set.
14. When System Data 3 is changed, circuit card (LC,ELC) initialization is required.
15. The following circuit card is required for Analog Caller ID:
16. When the multiple incoming...

Page 267

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 237
Dual Station Call D-156
D-156 Dual Station Call
General Description
This feature allows a user to simultaneously call two stations (referred as a Main Station and Sub Station), which
are accommodated in two different nodes within an FCCS network, by dialing one telephone number of the Main
Station. At that time, the call can be answered from either the Main or the Sub Station. Additionally, when this
service is used with...

Page 268

NEAX2400 IMX Business Features and Specifications
Page 238NDA-24221, Issue 3
D-156 Dual Station Call
Operating Procedure (cont’d)
c.) Dial Station A’s telephone number.
d.) Station A, Station B and Station C ring.
2. To answer a call via Station C:
a.) Station C answers.
b.) The caller is connected with Station C.
c.) Station A and Station B stop ringing.
d.) Station C presses Station A’s line.
e.) The caller hears MSC and Station C’s user hears ringback tone.
f.) Station C calls Station B as assigned...

Page 269

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 239
Dual Station Call D-156
Service Conditions (cont’d)
11. This service is activated in a Hotel/Motel system, but not activated with Hotel/Motel application service.
12. When a Sub Station is in communication, the telephone number of the Sub Station is sent to OAI or MFC
as Calling Number notification.
13. When a Sub Station is busy, a call terminates to the Main Station only. However, when a Main Station is
busy, a call is not...

Page 270

NEAX2400 IMX Business Features and Specifications
Page 240NDA-24221, Issue 3
D-156 Dual Station Call
Interactions (cont’d)
9. This service is not activated when a call is terminated via INTERCOM CALLING [I-9], AUTOMATIC/
MANUAL INTERCOM [A-30], DIAL INTERCOM [D-87] or MANUAL SIGNALING [M-47] (only the
Main Station rings).
10. This service is not activated while CALL BACK [C-1], CALL BACK DELAYED [C-73], CALL BACK-
CCIS [C-44], ATTENDANT CAMP-ON WITH TONE INDICATION [A-1] or ATTENDANT CAMP-
ON WITH TONE...