NEC Neax 2400 Imx Business Features And Specifications
Here you can view all the pages of manual NEC Neax 2400 Imx Business Features And Specifications. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 261
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 231 Delay Announcement - Attendant D-114 Service Conditions (cont’d) 7. The maximum programmable channels of DAT for this feature are: 1st announcement: 5 channels 2nd announcement: 5 channels 8. When a call encounters announcement trunks all busy, the call waits in a queue until a trunk becomes available. The latter trunk call hears ringback tone until the announcement to the former terminated call completes. 9. When providing the...
Page 262
NEAX2400 IMX Business Features and Specifications Page 232NDA-24221, Issue 3 D-114 Delay Announcement - Attendant Service Conditions (cont’d) 18. When this service is allowed in system data, the ATTENDANT OVERFLOW [A-105] feature cannot be activated. 19. When the external announcement machine is used, the announcement starts from the time when the PBX acknowledges the announcement trunk answer, and ends at the time of the announcement trunk release. 20. When activating this feature in an FCCS network,...
Page 263
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 233 Direct Station Selection (DSS) Console D-149 D-149 Direct Station Selection (DSS) Console General Description A Direct Station Selection (DSS) Console may be connected to each Dterm. The DSS keys can be used as line keys or feature keys. Operating Procedure Refer to the User Guide. Service Conditions 1. The DSS console has 60 keys, each with one or two lamps. 2. The DSS console has following two operating functions: a.)...
Page 264
NEAX2400 IMX Business Features and Specifications Page 234NDA-24221, Issue 3 D-149 Direct Station Selection (DSS) Console Service Conditions (cont’d) 7. The user can recognize the idle/busy status of the accommodated stations by the lamps. The left lamp (red) lights when busy and goes out when idle and shows incoming call, hold, etc. The right lamp (green) shows I-used, I-hold, etc. 8. The DSS console and the connected D term may be accommodated in the different circuit card, but should belong to the...
Page 265
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 235 Distinctive Ringing - Caller ID D-153 D-153 Distinctive Ringing - Caller ID General Description This feature is a part of CALLER ID service. This feature provides a distinctive ringing pattern (0, 1, 5, 6 or 7) according to the received calling number. Operating Procedure No manual operation is required. Service Conditions 1. On-off timing of Ringer Patterns 0, 1, 5, 6 and 7 can be changed using ASYD command. System data...
Page 266
NEAX2400 IMX Business Features and Specifications Page 236NDA-24221, Issue 3 D-153 Distinctive Ringing - Caller ID Service Conditions (cont’d) 13. Ringer patterns 2, 3 or 4 cannot be assigned for this feature. When one of those ringer patterns is assigned from the MAT, default value “Ringer pattern 6” is automatically set. 14. When System Data 3 is changed, circuit card (LC,ELC) initialization is required. 15. The following circuit card is required for Analog Caller ID: 16. When the multiple incoming...
Page 267
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 237 Dual Station Call D-156 D-156 Dual Station Call General Description This feature allows a user to simultaneously call two stations (referred as a Main Station and Sub Station), which are accommodated in two different nodes within an FCCS network, by dialing one telephone number of the Main Station. At that time, the call can be answered from either the Main or the Sub Station. Additionally, when this service is used with...
Page 268
NEAX2400 IMX Business Features and Specifications Page 238NDA-24221, Issue 3 D-156 Dual Station Call Operating Procedure (cont’d) c.) Dial Station A’s telephone number. d.) Station A, Station B and Station C ring. 2. To answer a call via Station C: a.) Station C answers. b.) The caller is connected with Station C. c.) Station A and Station B stop ringing. d.) Station C presses Station A’s line. e.) The caller hears MSC and Station C’s user hears ringback tone. f.) Station C calls Station B as assigned...
Page 269
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 239 Dual Station Call D-156 Service Conditions (cont’d) 11. This service is activated in a Hotel/Motel system, but not activated with Hotel/Motel application service. 12. When a Sub Station is in communication, the telephone number of the Sub Station is sent to OAI or MFC as Calling Number notification. 13. When a Sub Station is busy, a call terminates to the Main Station only. However, when a Main Station is busy, a call is not...
Page 270
NEAX2400 IMX Business Features and Specifications Page 240NDA-24221, Issue 3 D-156 Dual Station Call Interactions (cont’d) 9. This service is not activated when a call is terminated via INTERCOM CALLING [I-9], AUTOMATIC/ MANUAL INTERCOM [A-30], DIAL INTERCOM [D-87] or MANUAL SIGNALING [M-47] (only the Main Station rings). 10. This service is not activated while CALL BACK [C-1], CALL BACK DELAYED [C-73], CALL BACK- CCIS [C-44], ATTENDANT CAMP-ON WITH TONE INDICATION [A-1] or ATTENDANT CAMP- ON WITH TONE...