Page 231
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 201 Digital Display - Trunk D-6 D-6 Digital Display - Trunk General Description This feature provides the Attendant with a visual indication of incoming and outgoing trunk calls on the ATTENDANT CONSOLE [A-3]. Trunk identification number, trunk route number, and TENANT [T-12] number, or Central Office trunk code, are displayed in a numerical readout. Operating Procedure The DIGITAL DISPLAY TRUNK is automatically activated whenever...
Page 232
NEAX2400 IMX Business Features and Specifications Page 202NDA-24221, Issue 3 D-6 Digital Display - Trunk Service Conditions (cont’d) e.) an outgoing TIE Line call or re-enters a held trunk call. 7. An Attendant Console also indicates the C.O. code assigned by System Data at each node in the FCCS network.
Page 233
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 203 Direct-In Termination (DIT) D-7 D-7 Direct-In Termination (DIT) General Description This feature automatically routes incoming public network calls directly to a pre-selected station without Attendant assistance. The call can then be processed by the called party. THREE-WAY CALLING [T-2], CALL TRANSFER [C-10], etc., are handled in the same manner as any normal trunk call. Operating Procedure The calling party, outside the...
Page 234
NEAX2400 IMX Business Features and Specifications Page 204NDA-24221, Issue 3 D-7 Direct-In Termination (DIT) Service Conditions (cont’d) 17. When activating this feature via the FCCS network, when the telephone number of the destination station is deleted: a.) When the Attendant Console is used, the DIT call terminates to the Attendant Console. b.) When the Attendant Console is not used, or if the Attendant Console is in night mode, the caller hears ringback tone. 18. When activating this feature via the...
Page 235
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 205 Direct Inward Dialing (DID) D-8 D-8 Direct Inward Dialing (DID) General Description This feature provides for all incoming calls from the public network (except FX or WATS) to reach any system station without Attendant assistance. Operating Procedure The calling party, outside the system, dials the telephone number as usual. However, the call is answered directly at a predetermined station, bypassing the Attendant. Service...
Page 236
NEAX2400 IMX Business Features and Specifications Page 206NDA-24221, Issue 3 D-9 Direct Outward Dialing (DOD) D-9 Direct Outward Dialing (DOD) General Description This feature permits any user to gain access to the public network without the assistance of the Attendant, by dialing an access code and receiving a second dial tone. The user may then proceed to dial the desired public network number. Operating Procedure To place an outside call: 1. Go off-hook; receive dial tone, 2. Dial the trunk access...
Page 237
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 207 Distinctive Ringing D-10 D-10 Distinctive Ringing General Description This feature provides distinctive station ringing patterns so that the user can distinguish between internal and external incoming calls. Operating Procedure No manual operation is required. Service Conditions 1. This feature provides the following ringing patterns: a.) Ringing for Incoming Internal Call When a Service Feature Class that allows Personal...
Page 238
NEAX2400 IMX Business Features and Specifications Page 208NDA-24221, Issue 3 D-10 Distinctive Ringing Service Conditions (cont’d) 4. The DISTINCTIVE RINGING interruption rates can be optionally selected on a per-system basis. In this case, system initialization may be required. 5. An option is available on a per-trunk group basis to provide one-burst ringing on terminating calls. 6. When calling a third station (THREE-WAY CALLING [T-2], CONSULTATION HOLD [C-17], etc.), the ringing signal to the called...
Page 239
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 209 Do Not Disturb - DtermD-11D D-11D Do Not Disturb - Dterm General Description This feature allows a user to establish DO NOT DISTURB status. Incoming calls will be denied access to MY Line, while DO NOT DISTURB status is in effect. Operating Procedure To set DO NOT DISTURB: 1. Press the DO NOT DISTURB (DND) key. The associated LED will light. The LCD displays: To cancel DO NOT DISTURB: 2. Press the DO NOT DISTURB (DND) key....
Page 240
NEAX2400 IMX Business Features and Specifications Page 210NDA-24221, Issue 3 D-11D Do Not Disturb - Dterm Interactions 1. DO NOT DISTURB may be listed in some literature as available by a programmable Line/Feature key. A Dterm ACD station is not equipped with a DND key. If DO NOT DISTURB is to be made available to this station, it must be programmed to a Line/Feature key. 2. DATA INTERFACE-AUTOMATIC ANSWER may be activated if the D term station is in the DO NOT DISTURB mode.