NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 191
Calling Party Number - C-157
C-157  Calling Party Number -
         Name Assignment and Display
General Description
This feature allows a user to assign the desired name for the calling number, which is provided by Central Office,
CCIS or ISDN feature, using the MAT command. The assigned name is displayed on the LCD of the Dterm and the
Desk Console. 
Operating Procedure
No manual operation is required.
Service Conditions
1....

Page 222

NEAX2400 IMX Business Features and Specifications
Page 192NDA-24221, Issue 3
C-157 Calling Party Number - Name Assignment and Display
Service Conditions (cont’d)
12. The Display patterns are shown below:
13. Characters of 8-bit ASCII can be displayed for this feature.
14. When the feature key which assigned FKY = 113 via AKYD is pressed, the display pattern on the LCD
(assigned by the ASYD command) changes according to the following conditions:
 When My Line is Prime Line, Call ID Change Display Key is...

Page 223

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 193
Calling Party Number - Name Assignment and Display C-157
Service Conditions (cont’d)
18. The trunk mentioned below is available as for analog COT:
19. When this feature is activated via FCCS, the same data should be set to all nodes.
Circuit Card NameRemarks
PA - 8 C O T B J 

Page 224

NEAX2400 IMX Business Features and Specifications
Page 194NDA-24221, Issue 3
C-160 Call Trace
C-160 Call Trace
General Description
This feature enables the output of System Message [26-R], that gives information on a malicious call (kind of call,
number of calling terminal, etc.) originated from a station/trunk. The feature is made available when an access code
is dialed or the “Call Trace” key is pressed by the called user.
Note:For details on the System Message [26-R], see the NEAX2400 IMX System...

Page 225

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 195
Call Trace C-160
Operating Procedure (cont’d)
 When the CALL TRACE is assigned to the soft key:
 When HELP key (Soft Key) is pressed:
Service Conditions
1. This feature is made available via the stations, to which the following data is assigned via the ASFC
command [SFI = 170 (Call Trace), RES = 1 (Service: Allowed)].
2. This feature can be activated by analog or D
term stations. Other terminals such as Wireless stations...

Page 226

NEAX2400 IMX Business Features and Specifications
Page 196NDA-24221, Issue 3
C-160 Call Trace
Service Conditions (cont’d)
d.) The maximum digits for each data are as follows:
e.) When the called station does not have the telephone number, the FPC/Telephone Number/UGN
data is output as “0”.
f.) When the calling party is the station which does not have the telephone number, the Tenant
Number/FPC/Telephone Number/UGN data is output as “0”. The kind of call is output as “10”.
g.) If the number of the trunk...

Page 227

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 197
Dial Access To Attendant D-2
D-2 Dial Access To Attendant
General Description
This feature allows a user to access the ATTENDANT CONSOLE [A-3] by dialing the operator call code.
Operating Procedure
To access the Attendant: 
1. The user dials the operator call code; receives ringback tone. 
2. The ATND lamp for the INCOMING CALL IDENTIFICATION [I-2] flashes; Attendant answers the call.
Service Conditions
1. The operator call...

Page 228

NEAX2400 IMX Business Features and Specifications
Page 198NDA-24221, Issue 3
D-3 Dictation Access
D-3 Dictation Access
General Description
This feature permits users dial access to customer provided dictation equipment, and in some instances allows them
to maintain telephone dial control of normal dictation system features.
Operating Procedure
1. Dial the DICTATION ACCESS code. 
2. Proceed according to the dictation instructions provided by your organization.
Service Conditions
1. One trunk circuit is...

Page 229

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 199
Digital Display - Station D-5
D-5 Digital Display - Station
General Description
This feature provides the Attendant with a visual display (via the ATTENDANT CONSOLE [A-3]) of the telephone
number, its Trunk Route Restriction, CLASS OF SERVICE - INDIVIDUAL [C-15] and TENANT [T-12] number
during Attendant-to-station connection.
Operating Procedure
The DIGITAL DISPLAY STATION is automatically activated whenever the Attendant...

Page 230

NEAX2400 IMX Business Features and Specifications
Page 200NDA-24221, Issue 3
D-5 Digital Display - Station
Service Conditions (cont’d)
c.) answers a Recall or Call Forwarded call.
Example 2: 2-digit TENANT [T-12] number, 4-digit telephone number.
Example 3: 2-digit Trunk Route Restriction Class, 4-digit telephone number.
Example 4: Single digit TENANT [T-12] number, 5-digit telephone number.
Example 5: Single digit Trunk Route Restriction Class, 5-digit telephone number.
Example 6: When 5-digit station...