NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 271
FCCS Networking via IP F-36
F-36 FCCS Networking via IP
         (Series 7400 software feature)
General Description
This feature allows the system to exchange both speech and FCCS signals over Internet/Intranet. To establish/
release a call, the following two connection patterns can be selected:
 IPTRK Point-to-Point Connection: For both speech and FCCS signal channels, an IPTRK circuit card
is used. At this time, the IPTRK...

Page 302

NEAX2400 IMX Business Features and Specifications
Page 272NDA-24221, Issue 3
F-36 FCCS Networking via IP
Operating Procedure
No manual operation is required.
Service Conditions
Service Conditions for FCCS over IPTRK:
1. To send/receive voice information, each node shall use IPTRK circuit card(s). At this time, the IPTRK
cards in the self-node and its connected node(s) can be either in 1-to-1 ratio, respectively (called point-to-
point connection), or in 1-to-n [n=2 or more] relations (called...

Page 303

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 273
FCCS Networking via IP F-36
Service Conditions (cont’d)
11. Any service not available on the FCCS network, is not available with this feature.
12. Tandem Path through function is not provided.
13. This feature supports QoS (Quality of Service) function.
14. When a system message indicates TCP link failure due to data congestion on the router or IP network, a
call cannot be made via an IPTRK circuit card. When a call is...

Page 304

NEAX2400 IMX Business Features and Specifications
Page 274NDA-24221, Issue 3
F-36 FCCS Networking via IP
Service Conditions (cont’d)
Service Conditions for FCCS over IP using Cisco router:
1. DTI (1.5M and 2.0M) interface is used as speech channel.
2. The FCH-FGH card is used as a signal channel. Only a single FCH-FGH card can be connected to a router.
Accordingly, redundant configuration of FCH-FGH is not available.
3. An interface number is assigned to each speech channel and is changed into the TCP/IP...

Page 305

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 275
Group Calling G-2
G-2 Group Calling
General Description
This feature allows a user to dial certain frequently called stations within an NEAX2400 IMX group using an easily
remembered number. The same number can be assigned to different user groups. The group call can initiate CALL
WAITING - ORIGINATING [C-31] to a busy station.
Operating Procedure
To initiate a group call:
1. Lift the handset; receive dial tone. 
2. Dial the...

Page 306

NEAX2400 IMX Business Features and Specifications
Page 276NDA-24221, Issue 3
G-2 Group Calling
Service Conditions (cont’d)
b.) Dial the GROUP CALLING access code (maximum 3 digits). 
c.) Dial the GROUP CALLING station code (1 or 2 digits).
d.) CALL WAITING-ORIGINATING access code is not needed if automatic is set.
Interactions
1. As an example of a GROUP CALLING application, the following conditions exist:
System Station Numbering: 5XXXX and 6XXX
Speed Calling Access: 3 (Assigned in ASPA)
100 Groups of...

Page 307

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 277
Hotline H-1
H-1 Hotline
General Description
This feature permits a pair of station sets to be associated with one another on an automatic ringdown basis.
Operating Procedure
To place a HOTLINE call: 
1. Station A lifts the handset.
2. Station B is rung. 
3. Station B lifts the handset; the conversation proceeds.
Service Conditions
1. If both phones in a hotline pair are equipped with dials, either one may transfer a hotline...

Page 308

NEAX2400 IMX Business Features and Specifications
Page 278NDA-24221, Issue 3
H-1 Hotline
Interactions (cont’d)
2. CONSULTATION HOLD [C-17]: The HOTLINE station may put the destination station on
CONSULTATION HOLD [C-17]. In this state, the HOTLINE station may make an outgoing call, and is
therefore affected by CLASS OF SERVICE-INDIVIDUAL [C-15]. 
3. CALL WAITING-ORIGINATING [C-31]: A HOTLINE will not be allowed to camp-on to a busy
destination station.
4. If the connecting station is also a HOTLINE...

Page 309

NEAX2400 IMX Business Features and Specifications
NDA-24221, Issue 3
Page 279
House Phone H-2
H-2 House Phone
General Description
This feature allows selected stations to reach the ATTENDANT CONSOLE [A-1] by going off-hook.
Operating Procedure
To reach the ATTENDANT CONSOLE [A-1]: 
1. The HOUSE PHONE user lifts the handset. The Attendant is called automatically.
2. The Attendant answers. 
3. The Attendant connects the user to the desired station or trunk.
Service Conditions
1. Attendant Console...

Page 310

NEAX2400 IMX Business Features and Specifications
Page 280NDA-24221, Issue 3
H-4D Hands-free Answer Back - Dterm
H-4D  Hands-free Answer Back - Dterm
General Description
This feature allows the user to respond to a VOICE CALL - Dterm [V-2D] without lifting the handset.
Operating Procedure
To answer an incoming call:
1. Lift the handset and press the line key to answer the call. 
2. Press the feature key and “1”; the MIC LED lights. 
3. Press the feature key and “5” to select HANDS-FREE operation. 
4....