NEC Neax 2400 Imx Business Features And Specifications
Here you can view all the pages of manual NEC Neax 2400 Imx Business Features And Specifications. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 151
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 121 Call Transfer - All Calls C-11 Interactions (cont’d) 13.(Series 7400 software enhancement) The Camp-on by Station is not available when the target station uses PRIVACY RELEASE [P-18]. (Note) Note:The operating station hears busy tone when the destination is in the above condition. 14.(Series 7400 software enhancement) When the Camp-on by Station is set by automatic operation and the destination station is the UCD group member,...
Page 152
NEAX2400 IMX Business Features and Specifications Page 122NDA-24221, Issue 3 C-11D Call Transfer - All Calls - Dterm C-11D Call Transfer - All Calls - Dterm General Description This feature permits a Dterm user to transfer incoming or outgoing calls without Attendant assistance. (Series 7400 software enhancement) The Dterm user can set Camp-on function to the busy destination while transferring an incoming call (Camp-on by Station). With this feature, the trunk party is called back directly as the...
Page 153
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 123 Call Transfer - All Calls - DtermC-11D Operating Procedure (cont’d) 3. Method of operation: a.) When the access code is used, press the FLASH key; receive special dial tone and no indication on the LCD display, then dial the access code of CALL BACK; receive service set tone. b.) When the feature key/soft key is used, press the CALL BACK key; receive service set tone. The LCD of the operating station displays as mentioned above...
Page 154
NEAX2400 IMX Business Features and Specifications Page 124NDA-24221, Issue 3 C-11D Call Transfer - All Calls - Dterm Operating Procedure (cont’d) 2. Dial the third party, and the third party is busy; receive busy tone. The LCD of the operating station displays: The extension number of the third party 3. Replace the handset. The station to be set Camp-on by Station hears Warning Tone. The LCD of the operating party displays: The LCD display is changed after the trunk...
Page 155
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 125 Call Transfer - All Calls - DtermC-11D Service Conditions 1. The station performing the CALL TRANSFER - ALL CALLS can disconnect before the called party answers. If the called station does not answer within the predetermined time, ringing signal is returned to the transferring station. See VARIABLE TIMING PARAMETERS [V-1] for other selectable timing choices. 2. In the case of outgoing calls (no answer supervision), this feature...
Page 156
NEAX2400 IMX Business Features and Specifications Page 126NDA-24221, Issue 3 C-11D Call Transfer - All Calls - Dterm Service Conditions (cont’d) 13.(Series 7400 software enhancement) The Camp-on by Station is restricted when the target station is in the three-party connection. 14. (Series 7400 software enhancement) The Camp-on by Station is not available for the target station in LINE LOCKOUT [L-3] condition. 15. (Series 7400 software enhancement) The Camp-on by Station is not available in the following...
Page 157
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 127 Call Transfer - All Calls - DtermC-11D Interactions 1. This feature is denied whenever the transferring station is engaged in any state other than a simple two- party connection. 2. See TRUNK-TO-TRUNK CONNECTION [T-10] for additional programming if the call is to be transferred off network. 3. If a station is in an established THREE-WAY CALLING [T-2] connection, that station cannot activate any features. If a station switch...
Page 158
NEAX2400 IMX Business Features and Specifications Page 128NDA-24221, Issue 3 C-12 Call Waiting - Terminating C-12 Call Waiting - Terminating General Description This feature enables a busy station to receive a second incoming call. A Camp-On Indication Tone is sent to the busy station, the user can use a switch hook flash to answer the second call. A switch hook flash may be used to alternate between the two calls. Operating Procedure To activate CALL WAITING - TERMINATING from a station: 1. Dial the...
Page 159
NEAX2400 IMX Business Features and Specifications NDA-24221, Issue 3 Page 129 Call Waiting - Terminating C-12 Service Conditions (cont’d) 9. CALL WAITING - TERMINATING cannot be used in conjunction with DIAL ACCESS TO ATTENDANT [D-2]. 10. CALL WAITING - TERMINATING cannot be activated if the target station has accessed, entered, or is engaged in any of the following features or modes: ATTENDANT CAMP-ON WITH TONE INDICATION [A-1] ATTENDANT OVERRIDE [A-7] BOSS - SECRETARY OVERRIDE - D term[B-5D] BUSY...
Page 160
NEAX2400 IMX Business Features and Specifications Page 130NDA-24221, Issue 3 C-12 Call Waiting - Terminating Interactions (cont’d) 5. If ATTENDANT LOOP RELEASE [A-6] is not provided and CALL FORWARDING - DON’T ANSWER [C-3] via the Attendant Console is provided, a call extended to a station via the Attendant Console will wait at the station for the time set in Index 141 and will then be forwarded to the destination station for the time set in Index 145. Index 145 is the total time before recall. When that...