    							CHAPTER 2  TROUBLESHOOTING
    Fault Detection
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 63
    Application
    Processor CardsPN-SC03-A
     (CSH)RUN Green 120 IPM Flash Steady ON or OFF
    DOPE0Green Steady ON OFF
    DOPE1Green Steady ON OFF
    DOPE2Green Steady ON OFF
    DOPE3Green Steady ON OFF
    DOPE4Green Steady ON OFF
    DOPE5Green Steady ON OFF
    DOPE6Green Steady ON OFF
    DOPE7Green Steady ON OFF
    Line /Trunk Cards PN-2COTD
    (COT)
    [For Australia/
    Others]LF0 Red OFF Steady ON
    LF1 Red OFF Steady ON
    PN-4COTE
    (COT)
    [For Australia]LF0 Red OFF Steady ON
    LF1 Red OFF Steady ON
    LF2 Red OFF Steady ON
    LF3 Red OFF Steady ON
    PN-6COTJ
    (COT)
    [For Australia]LF0 Red OFF Steady ON
    LF1 Red OFF Steady ON
    LF2 Red OFF Steady ON
    LF3 Red OFF Steady ON
    LF4 Red OFF Steady ON
    LF5 Red OFF Steady ON
    Table 2-2  Lamp Indications on Circuit Cards (Continued)
    KIND OF
    CIRCUIT CARDCARD NAMELAMP 
    NAMECOLORINDICATIONS
    NORMAL ABNORMAL 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 64  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Detection
    Line/Trunk Cards PN-8COTT
    (COT)
    [For Australia]LF0 Red OFF Steady ON
    LF1 Red OFF Steady ON
    LF2 Red OFF Steady ON
    LF3 Red OFF Steady ON
    LF4 Red OFF Steady ON
    LF5 Red OFF Steady ON
    LF6 Red OFF Steady ON
    LF7 Red OFF Steady ON
    PN-2CSIA
    (CSI)
    [For North
    America/
    Latin America]OPE Green Steady ON OFF
    B12 Red ON/OFF 60 IPM Flash
    B11 Red ON/OFF 60 IPM Flash
    B10 Red ON/OFF 60 IPM Flash
    B02 Red ON/OFF 60 IPM Flash
    B01 Red ON/OFF 60 IPM Flash
    B00 Red ON/OFF 60 IPM Flash
    PN-2CSIA-A
    (CSI)
    [For Australia/
    Others]OPE Green Steady ON OFF
    B12 Red ON/OFF 60 IPM Flash
    B11 Red ON/OFF 60 IPM Flash
    B10 Red ON/OFF 60 IPM Flash
    B02 Red ON/OFF 60 IPM Flash
    B01 Red ON/OFF 60 IPM Flash
    B00 Red ON/OFF 60 IPM Flash
    PN-M03(M03) OPE Green Steady ON OFF
    PN-M10(M10) CK0 Green Steady ON OFF
    CK1 Green Steady ON OFF
    TALM Red OFF Steady ON
    RALM Red OFF Steady ON
    Table 2-2  Lamp Indications on Circuit Cards (Continued)
    KIND OF
    CIRCUIT CARDCARD NAMELAMP 
    NAMECOLORINDICATIONS
    NORMAL ABNORMAL 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 65
    FAULT DIAGNOSIS AND TROUBLESHOOTING
    Display on MAT/CAT
    When the MJ/MN alarm is on, you can diagnose the contents of the fault by the Fault Message
    and the Station Line Status Display features, which are displayed on the MAT or the CAT, and
    restore the fault.
    FAULT MESSAGE
    Item (1) shows the display format for the Fault Message feature, and item (2) shows the fault di-
    agnosis and troubleshooting method. For details of the Fault Message feature, see Fault Mes-
    sages on Page 5.
    (1) Display Format
    1:      01      MN      MP      00
    2:      99/10/24      20:31
    3:      X X    X X    X X    X X
    CPU Kind and No. that detected the fault
      MP 00 :  MP
      FP 00-03 :  FP No. 0-3
      AP 04-15, 20-31 :  AP No. 4-15, 20-31
    Alarm Kind (MJ/MN/–)
    Fault Occurrence Kind No./Fault Restoration Kind No.
    Date and Time of Fault Occurrence and Restoration
    Fault Information/
    Fault Restoration Information 
    (For details, see Table 2-3 and Table 2-4.)
    4:      X X    X X    X X    X X
    Fault Information/
    Fault Restoration Information 
    (For details, see Table 2-3 and Table 2-4.) 1st Screen
    2nd Screen
    3rd Screen
    4th Screen 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 66  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    (2) Fault Diagnosis and Troubleshooting
    Table 2-3 shows the fault information and the remedial action on each fault kind. Table 2-4
    shows the fault restoration information on each fault restoration kind. Diagnose contents of
    the fault and perform the remedial action listed in Table 2-3.
    If the corresponding fault restoration kind number shown in Table 2-4 also displays, no spe-
    cific action is required. 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 67
    Table 2-3  Remedial Action on Each Fault Kind 
    FAU LT  
    KIND
    NUMBERFAU LT  
    CONTENTFAULT INFORMATION REMEDIAL ACTION
    01 System initialized 3:  XX XX XX XX
           
    4: XX
     XX XX XX
     
    Kind of System Initialization 
    related information
    1: Program address 
    information
    2: Receive command 
    information
    F:  No system initialization 
    related information
    Initial Kind (See below.)
    The address of the program 
    which caused system 
    initialization
    Initial Kind 0: Power On Initialize No specific action is 
    required.
    Initial Kind 1: Initialize by Reset 
    Button (SW1)
    Initial Kind 2: Serious failure 1 Replace the MP card.
    Initial Kind 3: Serious failure 2 Replace the MP card.
    Initial Kind 5: Serious failure 3 Replace the MP card.
    Initial Kind 6: Serious failure 4 Replace the MP card.
    Initial Kind 7: Serious failure 5 Replace the MP card.
    Initial Kind 8: Serious failure 6 Replace the MP card.
    Initial Kind 9: SW3 was changed 
    to 0No specific action is 
    required.
    Initial Kind A:  Serious failure 7 Replace the MP card.
    Initial Kind B: Initialize by CAT/MAT No specific action is 
    required.
    123
    3
    1
    2
    3 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 68  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    04 MP-FP/AP commu-
    nication failure3: XX XX XX XX
         
    Communication Failure Kind
    00: Overflow of data sending 
    buffer to the FP/AP
    01: Invalid data received from 
    FP/AP
    Number of communication 
    failures 
    FP/AP Number
    00-03: FP No. 0-3
    04-15: AP No. 4-15, 20-31Replace the corre-
    sponding FP or AP 
    card indicated in the 
    FP/AP Number.
    08 FP/AP card down 3:  XX
     XX XX XX
    FP/AP Number
    00-03 :FP No. 0-3
    04-15, 20-31 :AP No. 4-
    15, 20-31Replace the corre-
    sponding FP or AP 
    card indicated in the 
    FP/AP Number.
    09 Power failure 3:  XX
     XX XX XX
    Power Failure Kind
    (See below.)
    Power Failure Kind 00: AC input 
    failureCheck to see if the AC 
    power source is cut off 
    or the plug is discon-
    nected.
    Power Failure Kind 01: Fuse break Check for a break in 
    the battery fuse.
    Power Failure Kind 02: PWR alarm
    Check the output 
    voltage of the PWR 
    card.
    Replace the PWR 
    card.
    Table 2-3  Remedial Action on Each Fault Kind (Continued)
    FAU LT  
    KIND
    NUMBERFAU LT  
    CONTENTFAULT INFORMATION REMEDIAL ACTION
    123
    1
    2
    3
    1
    2 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 69
    12 CS/ZT Fault 3. XX XX XXXX
           
    Fault Kind (See below.)
    AP No. of CS/ZT fault occur-
    rence 04-15, 20-31
    CS/ZT Interface No. of CS/ZT  
    fault occurrence 000-255
    Fault Kind 00: Fault notice from 
    CS/ZTNo specific action is 
    required.
    Fault Kind 01: CS/ZT initial failure
    Make the CS/ZT 
    Make busy or 
    Make idle condition 
    by CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch. 
    Fault Kind 02: CS/ZT condition 
    read failureMake the CS/ZT 
    Make busy or 
    Make idle condition 
    by CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch.
    Fault Kind 03: CS/ZT condition 
    unmatchNo specific action is 
    required.
    Fault Kind 04: B channel condition 
    unmatchNo specific action is 
    required.
    Table 2-3  Remedial Action on Each Fault Kind (Continued)
    FAU LT  
    KIND
    NUMBERFAU LT  
    CONTENTFAULT INFORMATION REMEDIAL ACTION
    123
    1
    2
    3
    1
    2
    1
    2 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 70  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    12 CS/ZT  Fault Fault  Kind  05: SYS-ID upload             
    failureCheck the LEN No. 
    of the CS/ZT with 
    SYS-ID is correct 
    by CMAE Y=00>02
    Make the CS/ZT 
    Make busy or 
    Make idle condition 
    by CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch.
    Fault Kind 06: SYS-ID download 
    failureWhen input the 
    SYS-ID from MAT, 
    check if the number 
    is correct.
    Check the CS/ZT 
    is CS/ZT without 
    SYS-ID
    Make the CS/ZT 
    Make busy or Make 
    idle condition by 
    CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch.
    Table 2-3  Remedial Action on Each Fault Kind (Continued)
    FAU LT  
    KIND
    NUMBERFAU LT  
    CONTENTFAULT INFORMATION REMEDIAL ACTION
    1
    2
    3
    1
    2
    3
    4 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 71
    12 CS/ZT Fault Fault Kind 07: CS/ZT make busy  
    failureMake the CS/ZT Make 
    busy or Make idle con-
    dition by CME5 Y=3.
    Fault Kind 08: CS/ZT data load 
    failureMake the CS/ZT 
    Make busy or 
    Make idle condition 
    by CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch.
    Fault Kind 09: B channel make 
    busy failureMake the CS/ZT 
    Make busy or 
    Make idle condition 
    by CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch.
    Fault Kind 0A: CS/ZT operation 
    parameter change 
    failureMake the CS/ZT 
    Make busy or 
    Make idle condition 
    by CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch.
    Table 2-3  Remedial Action on Each Fault Kind (Continued)
    FAU LT  
    KIND
    NUMBERFAU LT  
    CONTENTFAULT INFORMATION REMEDIAL ACTION
    1
    2
    1
    2
    1
    2 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 72  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    12 CS/ZT Fault Fault Kind 0B: LCCH sending 
    position failureMake the CS/ZT 
    Make busy or 
    Make idle condition 
    by CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch.
    Fault Kind 0C: Carrier selection 
    failure
    [North America/
    Latin America 
    Only]No specific action is 
    required.
    Fault Kind 0D: CS/ZT expansion 
    data read failureMake the CS/ZT 
    Make busy or 
    Make idle condition 
    by CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch.
    Fault Kind 0E: CS/ZT expansion 
    data setting failure Make the CS/ZT 
    Make busy or 
    Make idle condition 
    by CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch.
    Fault Kind 0F: CS/ZT operation 
    parameter
    2 changing failureMake the CS/ZT 
    Make busy or 
    Make idle condition 
    by CME5 Y=3.
    Tu r n  O N   OFF the 
    CS/ZT power 
    switch.
    Table 2-3  Remedial Action on Each Fault Kind (Continued)
    FAU LT  
    KIND
    NUMBERFAU LT  
    CONTENTFAULT INFORMATION REMEDIAL ACTION
    1
    2
    1
    2
    1
    2
    1
    2 
    						