NEC Neax 2000 Ivs2 Maintenance Manual
Have a look at the manual NEC Neax 2000 Ivs2 Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 2 TROUBLESHOOTING Fault Detection NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 63 Application Processor CardsPN-SC03-A (CSH)RUN Green 120 IPM Flash Steady ON or OFF DOPE0Green Steady ON OFF DOPE1Green Steady ON OFF DOPE2Green Steady ON OFF DOPE3Green Steady ON OFF DOPE4Green Steady ON OFF DOPE5Green Steady ON OFF DOPE6Green Steady ON OFF DOPE7Green Steady ON OFF Line /Trunk Cards PN-2COTD (COT) [For Australia/ Others]LF0 Red OFF Steady ON LF1 Red OFF Steady ON PN-4COTE (COT) [For Australia]LF0 Red OFF Steady ON LF1 Red OFF Steady ON LF2 Red OFF Steady ON LF3 Red OFF Steady ON PN-6COTJ (COT) [For Australia]LF0 Red OFF Steady ON LF1 Red OFF Steady ON LF2 Red OFF Steady ON LF3 Red OFF Steady ON LF4 Red OFF Steady ON LF5 Red OFF Steady ON Table 2-2 Lamp Indications on Circuit Cards (Continued) KIND OF CIRCUIT CARDCARD NAMELAMP NAMECOLORINDICATIONS NORMAL ABNORMAL
NEAX2000 IVS2 Maintenance ManualPage 64 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Detection Line/Trunk Cards PN-8COTT (COT) [For Australia]LF0 Red OFF Steady ON LF1 Red OFF Steady ON LF2 Red OFF Steady ON LF3 Red OFF Steady ON LF4 Red OFF Steady ON LF5 Red OFF Steady ON LF6 Red OFF Steady ON LF7 Red OFF Steady ON PN-2CSIA (CSI) [For North America/ Latin America]OPE Green Steady ON OFF B12 Red ON/OFF 60 IPM Flash B11 Red ON/OFF 60 IPM Flash B10 Red ON/OFF 60 IPM Flash B02 Red ON/OFF 60 IPM Flash B01 Red ON/OFF 60 IPM Flash B00 Red ON/OFF 60 IPM Flash PN-2CSIA-A (CSI) [For Australia/ Others]OPE Green Steady ON OFF B12 Red ON/OFF 60 IPM Flash B11 Red ON/OFF 60 IPM Flash B10 Red ON/OFF 60 IPM Flash B02 Red ON/OFF 60 IPM Flash B01 Red ON/OFF 60 IPM Flash B00 Red ON/OFF 60 IPM Flash PN-M03(M03) OPE Green Steady ON OFF PN-M10(M10) CK0 Green Steady ON OFF CK1 Green Steady ON OFF TALM Red OFF Steady ON RALM Red OFF Steady ON Table 2-2 Lamp Indications on Circuit Cards (Continued) KIND OF CIRCUIT CARDCARD NAMELAMP NAMECOLORINDICATIONS NORMAL ABNORMAL
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 65 FAULT DIAGNOSIS AND TROUBLESHOOTING Display on MAT/CAT When the MJ/MN alarm is on, you can diagnose the contents of the fault by the Fault Message and the Station Line Status Display features, which are displayed on the MAT or the CAT, and restore the fault. FAULT MESSAGE Item (1) shows the display format for the Fault Message feature, and item (2) shows the fault di- agnosis and troubleshooting method. For details of the Fault Message feature, see Fault Mes- sages on Page 5. (1) Display Format 1: 01 MN MP 00 2: 99/10/24 20:31 3: X X X X X X X X CPU Kind and No. that detected the fault MP 00 : MP FP 00-03 : FP No. 0-3 AP 04-15, 20-31 : AP No. 4-15, 20-31 Alarm Kind (MJ/MN/–) Fault Occurrence Kind No./Fault Restoration Kind No. Date and Time of Fault Occurrence and Restoration Fault Information/ Fault Restoration Information (For details, see Table 2-3 and Table 2-4.) 4: X X X X X X X X Fault Information/ Fault Restoration Information (For details, see Table 2-3 and Table 2-4.) 1st Screen 2nd Screen 3rd Screen 4th Screen
NEAX2000 IVS2 Maintenance ManualPage 66 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting (2) Fault Diagnosis and Troubleshooting Table 2-3 shows the fault information and the remedial action on each fault kind. Table 2-4 shows the fault restoration information on each fault restoration kind. Diagnose contents of the fault and perform the remedial action listed in Table 2-3. If the corresponding fault restoration kind number shown in Table 2-4 also displays, no spe- cific action is required.
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 67 Table 2-3 Remedial Action on Each Fault Kind FAU LT KIND NUMBERFAU LT CONTENTFAULT INFORMATION REMEDIAL ACTION 01 System initialized 3: XX XX XX XX 4: XX XX XX XX Kind of System Initialization related information 1: Program address information 2: Receive command information F: No system initialization related information Initial Kind (See below.) The address of the program which caused system initialization Initial Kind 0: Power On Initialize No specific action is required. Initial Kind 1: Initialize by Reset Button (SW1) Initial Kind 2: Serious failure 1 Replace the MP card. Initial Kind 3: Serious failure 2 Replace the MP card. Initial Kind 5: Serious failure 3 Replace the MP card. Initial Kind 6: Serious failure 4 Replace the MP card. Initial Kind 7: Serious failure 5 Replace the MP card. Initial Kind 8: Serious failure 6 Replace the MP card. Initial Kind 9: SW3 was changed to 0No specific action is required. Initial Kind A: Serious failure 7 Replace the MP card. Initial Kind B: Initialize by CAT/MAT No specific action is required. 123 3 1 2 3
NEAX2000 IVS2 Maintenance ManualPage 68 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting 04 MP-FP/AP commu- nication failure3: XX XX XX XX Communication Failure Kind 00: Overflow of data sending buffer to the FP/AP 01: Invalid data received from FP/AP Number of communication failures FP/AP Number 00-03: FP No. 0-3 04-15: AP No. 4-15, 20-31Replace the corre- sponding FP or AP card indicated in the FP/AP Number. 08 FP/AP card down 3: XX XX XX XX FP/AP Number 00-03 :FP No. 0-3 04-15, 20-31 :AP No. 4- 15, 20-31Replace the corre- sponding FP or AP card indicated in the FP/AP Number. 09 Power failure 3: XX XX XX XX Power Failure Kind (See below.) Power Failure Kind 00: AC input failureCheck to see if the AC power source is cut off or the plug is discon- nected. Power Failure Kind 01: Fuse break Check for a break in the battery fuse. Power Failure Kind 02: PWR alarm Check the output voltage of the PWR card. Replace the PWR card. Table 2-3 Remedial Action on Each Fault Kind (Continued) FAU LT KIND NUMBERFAU LT CONTENTFAULT INFORMATION REMEDIAL ACTION 123 1 2 3 1 2
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 69 12 CS/ZT Fault 3. XX XX XXXX Fault Kind (See below.) AP No. of CS/ZT fault occur- rence 04-15, 20-31 CS/ZT Interface No. of CS/ZT fault occurrence 000-255 Fault Kind 00: Fault notice from CS/ZTNo specific action is required. Fault Kind 01: CS/ZT initial failure Make the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Fault Kind 02: CS/ZT condition read failureMake the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Fault Kind 03: CS/ZT condition unmatchNo specific action is required. Fault Kind 04: B channel condition unmatchNo specific action is required. Table 2-3 Remedial Action on Each Fault Kind (Continued) FAU LT KIND NUMBERFAU LT CONTENTFAULT INFORMATION REMEDIAL ACTION 123 1 2 3 1 2 1 2
NEAX2000 IVS2 Maintenance ManualPage 70 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting 12 CS/ZT Fault Fault Kind 05: SYS-ID upload failureCheck the LEN No. of the CS/ZT with SYS-ID is correct by CMAE Y=00>02 Make the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Fault Kind 06: SYS-ID download failureWhen input the SYS-ID from MAT, check if the number is correct. Check the CS/ZT is CS/ZT without SYS-ID Make the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Table 2-3 Remedial Action on Each Fault Kind (Continued) FAU LT KIND NUMBERFAU LT CONTENTFAULT INFORMATION REMEDIAL ACTION 1 2 3 1 2 3 4
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 71 12 CS/ZT Fault Fault Kind 07: CS/ZT make busy failureMake the CS/ZT Make busy or Make idle con- dition by CME5 Y=3. Fault Kind 08: CS/ZT data load failureMake the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Fault Kind 09: B channel make busy failureMake the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Fault Kind 0A: CS/ZT operation parameter change failureMake the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Table 2-3 Remedial Action on Each Fault Kind (Continued) FAU LT KIND NUMBERFAU LT CONTENTFAULT INFORMATION REMEDIAL ACTION 1 2 1 2 1 2
NEAX2000 IVS2 Maintenance ManualPage 72 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting 12 CS/ZT Fault Fault Kind 0B: LCCH sending position failureMake the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Fault Kind 0C: Carrier selection failure [North America/ Latin America Only]No specific action is required. Fault Kind 0D: CS/ZT expansion data read failureMake the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Fault Kind 0E: CS/ZT expansion data setting failure Make the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Fault Kind 0F: CS/ZT operation parameter 2 changing failureMake the CS/ZT Make busy or Make idle condition by CME5 Y=3. Tu r n O N OFF the CS/ZT power switch. Table 2-3 Remedial Action on Each Fault Kind (Continued) FAU LT KIND NUMBERFAU LT CONTENTFAULT INFORMATION REMEDIAL ACTION 1 2 1 2 1 2 1 2