    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 103
    (3)  If Dial Tone is returned after seizing 
    the original trunk, there is a 
    problem with the distant office, the 
    Carrier Equipment, or the line. 
    (4)  If not, check for trouble with wiring 
    on the MDF and the trunk card.
    Any dialed digit is not transmit-
    ted to the distant office.(1)  System Data Programming for the 
    trunk route: CM35 Y=01, 08, 20 
    (2)  When the Sender Start condition is 
    set to Wink or Delay Dial by CM35 
    Y=20, check if answer signal is 
    returned from the distant office.
    (1) Trunk card 
    (2) FP card
    (3) MP card
    B
    C
    ~
    MDF
    DT ODT
    ODTE
    M
    E
    M
    CHECK
    REPLACE 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 104  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    After dialing the first digit, Dial 
    Tone from the distant office is 
    not disconnected.(1)  Appropriate signal (DP/DTMF) to 
    distant office is transmitted. 
      System Data Programming for DP 
    signal: CM35 Y=01, 13, 23, 25, 45 
      System Data Programming for 
    DTMF signal: CM35 Y=01, 13, 24, 
    26, 46
    (2)  System Data Programming for 
    Numbering Plan: CM20>A100-
    A163, 
    CM20>A200-A231, 
    CM22, CM23, CM26
    (1) Trunk card 
    (2) FP card
    (3) MP card
    C
    END
    CHECK
    REPLACE 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 105
    (2) On Incoming Call
    C.O. Incoming Call is not termi-
    nated to ATTCON Station, DIT 
    or TAS Buzzer.
    BL lamp on the trunk 
    card is not turned on.(1)  Disconnect the trunk from the line 
    on the MDF. 
    (2)  Connect a test telephone set to the 
    line on the MDF. 
    (3)  If the telephone rings, check for 
    trouble with wiring on the MDF and 
    the trunk card. 
    (4)  If not, there is a problem with the 
    distant office or the line.
    (1) Trunk card
    BL lamp is turned on. (1)  System Data Programming for the 
    trunk 
      In case of Termination to DIT sta-
    tion: CM30 Y=02, 03, 04, 05, 13, 
    14, 17, CM35 Y=09 
      In case of Termination to TAS 
    Buzzer: CM30 Y=02, 03 START
    A
    CHECK
    MDF
    TRUNK
    To C.O. Line
    Test Telephone Set
    ATTCON
    REPLACE
    CHECK 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 106  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    No Dial Tone Connection on 
    Tie Line Incoming Call (only for 
    the 2nd dial tone system)(1)  In case all Tie Line Trunks fail, check 
    if DTMF Receivers for Tie Line 
    Incoming Call are installed (only 
    when the signal kind of the trunk is 
    DTMF).
    In case of ODT card (1)  System Data Programming for the 
    trunk: CM35 Y=00, 09, 10.
    (2)  Disconnect trunk from the line on 
    the MDF. 
    (3)  To perform a Loop-Back Test, make 
    a back to back connect of the trunk 
    and another trunk within the system 
    at the MDF. 
    (4)  If Dial Tone is returned when the call 
    is terminated to the original trunk, 
    there is a problem with the distant 
    office, the Carrier Equipment, or the 
    line. 
    (5)  If not, check for trouble with wiring 
    on the MDF and the trunk card.
    (1) Trunk card
    A
    BCHECK
    CHECK
    ~
    MDF
    DT ODT
    ODTE
    M
    E
    M
    REPLACE 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 107
    The Tie Line Incoming Call/DID 
    Call is routed to a different 
    station other than the dialed 
    station, or to Reorder Tone.(1)  System Data Programming for the 
    trunk: CM35 Y=01, 17, 61-68
    (1) Trunk card 
    (2) FP card
    (3) MP card
    B
    END
    CHECK
    REPLACE 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 108  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    (3) On Answering the Call
    Speech Path Trouble: 
    No connection/One way 
    connection(1)  Disconnect the trunk from the line 
    on the MDF. 
    (2)  To perform the Speech Path Test 
    internally, make the following 
    connection on the MDF according 
    to type of card.  START
    ACHECK
    MDF
    ODT
    ODTE
    M
    E
    M
    MDF
    COT
          
    ATTCON
    STATION PORT
     In Case of COT Card
     In Case of ODT Card 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 109
    (3)  If the trouble remains, replace the 
    trunk card. 
    (4)  If not, there is a problem with the 
    distant office.
    (1) Trunk card 
    (2) FP card
    (3) MP card
    Call is dropped (This condition 
    excludes the Line Fault 
    detected within a system).
    When the station user 
    flashes the switch-hook(1)  System Data Programming for the 
    trunk: CM35 Y=16
    When the failure 
    occurs suddenly(1)  Disconnect the trunk from the line 
    on the MDF. 
    (2)  Connect a test telephone set to the 
    line on the MDF, and check if the 
    failure reoccurs. 
    (3)  If the failure recurs, there is a 
    problem with the distant office. 
    (4)  If not, replace the trunk card.
    (1) Trunk card
    (2) FP card
    (3) MP card
    A
    B
    REPLACE
    CHECK
    CHECK
    REPLACE 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 110  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    Transmission quality is not 
    acceptable.
    Noise/Distor tion (1)  Cabling between the PBX and the 
    MDF or between the MDF and the 
    lines is properly run to avoid 
    induction from an AC power cable, 
    motor or power supply equipment.
    (1) Trunk card
    (2) FP card
    (3) MP card
    (4) PWR card
    Low Voice Level (1)  Loose connection of cables on the 
    MDF
    (1) Trunk card
    (2) FP card
    (3) MP card
    Cross Talk (1)  Proper wiring on the MDF
    (1) Trunk card
    (2) FP card
    (3) MP card
    (4) PWR card
    B
    END
    CHECK
    REPLACE
    CHECK
    REPLACE
    CHECK
    REPLACE 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 111
    POWER FAILURE TRANSFER (PFT) FAULT
    Preassigned stations are not 
    connected to the C.O. line 
    when system alarm or power 
    failure has occurred.(1)  Cross connection on the MDF is 
    properly made. 
    (2)  Proper connection between the 
    AUC card and the COT card
    (1) AUC card
    PFT operates without Power 
    Failure or Emergency Alarm.(1) AUC card
    (2) MP card START
    END
    CHECK
    REPLACE
    REPLACE 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 112  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    Dterm FAULT
    This troubleshooting procedure covers faults with the D
    term function only. For other faults, see
    Station Line Fault on Page 98.
    All Keys on the D
    term are 
    ineffective.(1) Wiring on Modular Box (Rosette) 
    (2) DLC card is properly mounted.
    (3) System Data Programming for the 
    D
    term station: CM10, CM11, CM12, 
    CM13, CM90, CM93 
    (4) RUN lamp on the FP card and MP 
    card is flashing.
    (1) D
    term 
    (2) DLC card
    (3) FP card
    (4) MP card
    Speech Path Trouble: 
    No Connection/One Way 
    Connection(1) D
    term 
    (2) DLC card
    Hands Free Operation is not 
    available.(1) MIC lamp is on. 
    (2)  Adjust speaker volume. 
    (3)  Built-in Hands Free Unit is properly 
    mounted.
    (1)  Hands Free Unit within D
    term 
    (2) D
    term
    START
    A
    CHECK
    REPLACE
    REPLACE
    CHECK
    REPLACE 
    						