    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 93
    PN-2CSIA (CSI)
    [For North
    America/
    Latin America]OPE lamp is not 
    onD channel link is 
    not connected 
    between CSH 
    and CSIConfirm the programming data: 
    CM06 Y=10.
    Confirm if the corresponding  
    CSH card is removed.
    If the fault cannot be cleared, 
    replace the card.
    B00-B12 lamp is 
    flashingZT is not 
    connected to the 
    corresponding 
    circuit No. Confirm the programming data: 
    CM06, CM10, CMAD.
    Confirm cable connection and the 
    power switch of the correspond-
    ing ZT.
    Confirm if the corresponding ZT 
    is in make-busy status  
    PN-2CSIA-A
    (CSI)
    [For Australia/
    Others]OPE lamp is not 
    onD channel link is 
    not connected 
    between CSH 
    and CSIConfirm the programming data: 
    CM06 Y=10.
    Confirm if the corresponding  
    CSH card is removed.
    If the fault cannot be cleared, 
    replace the card.
    B00-B12 lamp is 
    flashingCS is not 
    connected to the 
    corresponding 
    circuit No. Confirm the programming data: 
    CM06, CM10, CMAD.
    Confirm cable connection and the 
    power switch of the correspond-
    ing CS.
    Confirm if the corresponding CS 
    is in make-busy status  
     PN-M03(M03)  OPE lamp is not
     onAbnormal con-
    nection with the 
    DPC Confirm the connection with DPC 
    card.
    If the fault cannot be cleared, 
    replace the card.
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    1
    2
    3
    1
    2
    3
    1
    2
    3
    1
    2 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 94  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    PN-M10 (M10) CK0 lamp is not 
    onCable connec-
    tion failure 
    between Digital 
    Trunk Interface 
    and No. 0 circuit 
    of M10Check to see if the cable between 
    Digital Trunk Interface and M10 is 
    correctly connected.
    Check the switch setting of M10.
    If the fault cannot be cleared, 
    replace the card.
    CK1 lamp is not 
    onCable connec-
    tion failure 
    between Digital 
    Trunk Interface 
    and No. 1 circuit 
    of M10Check to see if the cable between 
    Digital Trunk Interface and M10 is 
    correctly connected.
    Check the switch setting of M10.
    If the fault cannot be cleared, 
    replace the card.
    TALM lamp is on Optical output 
    line faultCheck to see if the cable between 
    Digital Trunk Interface and M10 is 
    correctly connected.
    Check the switch setting of M10.
    If the fault cannot be cleared, 
    replace the card.
    RALM lamp is on Optical input line 
    faultCheck to see if the optical cable 
    between the own side M10 and 
    the remote side M10 is correctly 
    connected.
    Check the switch setting of own 
    side M10 and remote side M10.
    If the fault cannot be cleared, 
    replace the card.
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    1
    2
    3
    1
    2
    3
    1
    2
    3 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 95
    Troubleshooting by Contents of Complaint
    This section describes the troubleshooting method when you receive a complaint of a problem
    from a station user or an operator. Select the appropriate section corresponding to the problem
    in Figure 2-4 and perform the troubleshooting.
    Figure 2-4  Sections for Troubleshooting Procedure
    Complaint from Station User/Operator
    Station Line Fault   (Page 98)
    (1) At Calling Station
    (2) At Called Station
    C.O. Line/Tie Line Fault   (Page 101)
    (1) On Outgoing Call
    (2) On Incoming Call
    (3) On Answering Call
    Power Failure Transfer (PFT) Fault  (Page 111)
    D
    term Fault   (Page 112)
    ATTCON Fault   (Page 114)
    DSS Console Fault    
    (Page 116)
    ATTCON Self-Test Procedure    (Page 117) 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 96  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    EXPLANATION OF SYMBOLS IN TROUBLESHOOTING PROCEDURE
    The following markings explain the instruction marks used in the troubleshooting procedures.
    : With respect to the item indicated on the right side of this mark, perform a check
    or the required work. If an abnormality is found, take the required remedial action,
    such as repair, replacement, etc.
    : Replace the equipment or device (considered to be the fault) indicated on the right
    side of the mark with a spare and confirm the recovery of the fault.
    HOW TO FOLLOW THE “TREE”
    The troubleshooting procedure is explained in the form of a “Tr e e”. Troubleshooting can be per-
    formed accurately, as well as efficiently, by following the related “Tr e e” path according to the in-
    formation available on the fault. In the following information gives a step-by-step explanation
    about how to use the “Tr e e .”
    Step 1: The maintenance personnel gathers information concerning the fault and selects the
    tree to use from Figure 2-4.
    Step 2: In the selected tree, search the item concerned by checking the symptom one by one
    following the tree downward from the “START” point. If the related item has not been
    found, gather more detailed information concerning the fault.
    Step 3: The items indicated by the   mark on the right side of the items concerned
    suggest elements that are possibly responsible for the fault. Check each of these items.
    If an abnormality is found, perform the necessary remedial action such as repair, re-
    placement, etc.
    Step 4: If the fault is not recovered after a check was made on the items indicated by the
     mark and necessary actions were taken, replace the circuit card(s) and oth-
    er hardware indicated by the   mark with spare(s). In this case, every time
    hardware is replaced with a spare, check whether the fault is recovered. CHECK
    REPLACE
    CHECK
    CHECK
    REPLACE 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 97
    Figure 2-5  How to Follow the “Tr e e”
    START
    END
    Symptom
    Step 2
    CHECK
    REPLACEStep 3-1
    (1)
    Step 3-2
    (2)
    Step 4-1
    (1)Step 3-3
    (3)
    Step 4-2
    (2) 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 98  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    STATION LINE FAULT
    (1) At Calling Station
    Side Tone cannot be heard. (1) On the MDF, connect a test 
    telephone set to the faulty station 
    line.
    (2)  If Side Tone is heard, check for 
    trouble with the cabling and 
    telephone set.
    (3)  If no Side Tone is heard, check for 
    trouble with wiring on the MDF and 
    LC card.
    (1) LC card
    (2) Telephone set
    Dial Tone is not returned.
    The station telephone 
    set is DTMF type.(1)  System Data Programming for 
    DTMF Receiver: CM10, CM45 Y=0 
    NOTE:Addition of an RST requires a
    system reset.
    (2)  System Data Programming for the 
    station: CM10, CM12 Y=00
    System does not 
    receive any digits 
    dialed by the station.(1)  MB switch on the FP card is set 
    downward.
    (2)  RUN lamp on the FP or MP card is 
    flashing.
    (1) FP card
    (2) MP card START
    ACHECK
    REPLACE
    CHECK
    CHECK
    REPLACE 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 99
    After dialing the first digit, Dial 
    Tone is not disconnected.
    At DTMF telephone set (1)  System Data Programming for the 
    station: CM12 Y=00
    (1)  PBR card (DTMF Receiver)
    (2) LC card
    (3) Telephone set
    At any type of 
    telephone set(1)  System Data Programming for the 
    station: CM12 Y=00
    (1) LC card
    (2) Telephone set
    END
    A
    CHECK
    REPLACE
    CHECK
    REPLACE 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 100  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    (2) At Called Station
    At the called station, the tele-
    phone does not ring.(1)  ON lamp on the PWR card is on.
    (2)  Volume Control of the telephone 
    set.
    (1) LC card
    (2) Telephone set 
    (3) PWR card (In case all stations fail 
    within same PIM.)
    The call is routed to a station 
    other than the dialed number.(1)  System Data Programming for 
    destination station Number: CM10
    (2)  Call Forwarding-All Calls feature is 
    activated at the destination station.
    Ringing Signal is not discon-
    nected after going off-hook.(1) LC card
    (2) FP card
    (3) MP card 
    (4) Telephone set START
    END
    CHECK
    REPLACE
    CHECK
    REPLACE 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 101
    C.O. LINE/TIE LINE FAULT
    (1) On Outgoing Call
    After dialing the trunk access 
    code, tone (Reorder Tone) is 
    returned.
    BL lamp on the trunk 
    card is flashing.(1)  Make Busy Data (CME5) of the 
    trunk. 
    (2)  System Data programming for the 
    trunk: CM10
    BL lamp on the trunk 
    card is on.(1)  Disconnect the trunk from the line 
    on the MDF. 
    (2)  If the lamp goes out, there is a 
    problem with the Central Office/
    Distant Office or Cable. 
    (3)  If not, check for a problem with 
    wiring on the MDF or the trunk 
    card.
    (1) Trunk card
    No lamp indication on 
    the trunk card(1)  System Data Programming for the 
    station restriction service class: 
    CM12 Y=01 START
    A
    CHECK
    CHECK
    REPLACE
    CHECK 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 102  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    Dial Tone is not returned from 
    distant office.
    In case of COT card (1)  Disconnect the trunk from the line 
    on the MDF. 
    (2)  Connect a test telephone set to the 
    C.O. line (distant office side) on the 
    MDF. 
    (3)  If Dial Tone is returned by going off-
    hook on the test telephone set, 
    check for trouble with wiring on the 
    MDF and the trunk card. 
    (4)  If not, there is a problem with the 
    distant office or the C.O. line.
    (1) Trunk card
    In case of ODT card (1)  Disconnect the trunk from the line 
    on the MDF.
    (2)  To perform a Loop-Back Test, 
    make a back to back connection of 
    the trunk card and another trunk 
    within the system at the MDF.
    NOTE: This test only works when the
    trunks are assigned for type V
    operation.
    A
    B
    CHECK
    SW MDF
    TRUNK
    To Distant Office
    Test Telephone Set
    REPLACE
    CHECK 
    						