    							CHAPTER 2  TROUBLESHOOTING
    Precautions
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 53
    Static Electricity Guard
    You must wear a grounded wrist strap to protect circuit cards from static electricity.
    Figure 2-1  Static Electricity Guard (1 of 2)
    WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD
    WHEN HOLDING A CIRCUIT CARD
    PBX
    WRIST STRAP
    FRAME GROUND SCREW
    CARD FRONT
    NEVER TOUCH THE COMPONENTS OR 
    SOLDERED SURFACE WITH BARE HANDS. 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 54  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Precautions
    Figure 2-1  Static Electricity Guard (2 of 2)
    WHEN MAKING A SWITCH SETTING ON A CIRCUIT CARD
    WHEN CARRYING A CIRCUIT CARD
    WEAR A WRIST STRAP AND PERFORM
    THE WORK ON A GROUNDED
    CONDUCTIVE WORK SURFACE.
    CIRCUIT
    CARD
    WHEN CARRYING A CIRCUIT CARD 
    AROUND, KEEP THE CARD IN A
    CONDUCTIVE POLYETHYLENE BAG.
    CIRCUIT
    CARDCONDUCTIVE
    POLYETHYLENE
    BAG 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Precautions
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 55
    CAUTION
    You must hold the edge of a circuit card when plugging or unplugging the circuit card. If you
    touch another area, you may be exposed to hazardous voltages.
    CARD FRONT
    NEVER TOUCH THE COMPONENTS 
    OR SOLDERED SURFACE WITH 
    BARE HANDS.
    PBX 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 56  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Precautions
    Turning Power ON
    (1) Check the switch position of each PZ-PW121 card before turning power on.
    Make sure that the AC120V/240V selector switch is positioned to appropriate voltage for 
    each country (AC120V or AC240V).
    Make sure that the battery mode selector switch is positioned as shown below to meet the 
    kind of battery:
    (2) Turn the SW1 switches of all the PZ-PW121 cards to ON. First, turn ON PIM1 to PIM7. 
    Then, turn ON PIM0 last of all.
    CAUTION
    1. When the operating power is being supplied to the PZ-PW121 card, do not plug/unplug this
    circuit card into/from its mounting slot.
    2. When the system is configured with two or more PIMs, the BUS cable provides gang control
    for the PZ-PW121 card of PIM0 and other PIMs. Therefore, if the power of PIM0 is off, no
    power is supplied to the whole system even when the power switch(es) of other PIMs are
    left on. Note, however, that the battery continues to charge even under these circumstances.
    3. Do not turn off the PZ-PW121 card on PIM1 to PIM7 when the system is operating.
    SW
    240V 100V/120V
    ON OFF
    12
    SW101
    1 : Not used 
    2 : ON   (SEAL/FLOAT2) 
         OFF (OPEN/FLOAT1) 
      
    						
    							CHAPTER 2  TROUBLESHOOTING
    Precautions
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 57
    Turning Power OFF
    (1) Before turning power off, make sure that all line/trunk cards are not operating by no busy 
    lamps indication.
    (2) Turn the SW1 switches of all the PZ-PW121 cards to OFF. First, turn OFF PIM0. Then, turn 
    OFF PIM1 to PIM7. 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 58  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Outline of Troubleshooting
    OUTLINE OF TROUBLESHOOTING
    Figure 2-2 shows an outline of the recommended troubleshooting procedure.
    Figure 2-2  Troubleshooting Outline
    START
    FAULT DIAGNOSIS
    AND
    TROUBLESHOOTING
    Fault Detection Method (See Page 59.)
    (1) Alarm Indication on PWRU, Alarm Display
    Panel
    (2) Lamp Indication on Circuit Cards
    (3) Complaint from station user or operator
    Fault Diagnosis and Troubleshooting Method
    (1) Display on MAT/CAT (See Page 65.)
    Fault Message
    Station Line Status Display
    (2) Lamp Indication on Cards
    (See Page 83
    .)
    (3) Contents of complaint from station user 
    or operator (See Page 95
    .)FAULT DETECTION
    END 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Detection
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 59
    FAULT DETECTION
    This section describes the way in which alarm indications are given. If a fault occurs in the sys-
    tem, you can detect the fault via the routes shown in Figure 2-3.
    Figure 2-3  Alarm Indication Routes
    PWR CARD
    MJ
    MN
    ON PWR
    MJMN
    ALARM DISPLAY PANEL
    MJ/MN ALARM
    INDICATION
    MJ/MN ALARM
    INDICATION
    LAMP INDICATION
    CIRCUIT CARD MAINTENANCE
    PERSONNEL
    COMPLAINT FROM
    STATION USER OR OPERATOR 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 60  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Detection
    (1) Fault Detection by Alarm Indication
    When a fault occurs in the system, you can detect the fault by a Major (MJ) alarm or Minor
    (MN) alarm indicated on the AC/DC PWR card or by the external Alarm Display Panel.
    (2) Fault Detection by Lamp Indication on Circuit Cards
    When a fault occurs in the system, you can detect the fault by lamp indication on circuit
    cards, such as a Major (MJ) or Minor (MN) alarm indicated on the MP card. Table 2-2 iden-
    tifies the alarm indication lamps on each circuit card. For details of lamp indication on circuit
    cards, refer to the Installation Procedure Manual.
    (3) Fault Detection by Complaint from Station User or Operator
    When you receive a complaint about a problem from a station user or an operator, collect
    as much information on the problem as possible, and then troubleshoot the problem accord-
    ing to the procedure in Troubleshooting by Contents of Complaint on Page 95. 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Detection
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 61
    Table 2-2  Lamp Indications on Circuit Cards 
    KIND OF
    CIRCUIT CARDCARD NAMELAMP 
    NAMECOLORINDICATIONS
    NORMAL ABNORMAL
    Control Cards PN-CP14 (MP) RUN Green 120 IPM Flash Steady ON or OFF
    PN-CP15 (FP) RUN Green 120 IPM Flash Steady ON or OFF
    PN-PW00
    (EXTPWR)RUN Green Steady ON OFF
    PZ-PW121
    (AC/DC PWR)ON Green Steady ON OFF
    PZ-PW122
    (DC/DC PWR)ON Green Steady ON OFF
    Application
    Processor CardsPN-AP00-A
     (DBM)RUN Green 120 IPM Flash Steady ON or OFF
    PN-AP00-B
     (AP00)RUN Green 120 IPM Flash Steady ON or OFF
    PN-AP01
     (AP01)RUN Green 120 IPM Flash Steady ON or OFF
    PN-BRTA (BRT) RUN Green 120 IPM Flash Steady ON or OFF
    ALM Red OFF Steady ON
    PN-2BRTC
    (BRT)RUN Green 120 IPM Flash Steady ON or OFF
    ALM0 Red OFF Steady ON
    ALM1 Red OFF Steady ON
    PN-CC01
    (ETHER)RUN Green 60 IPM Flash Steady ON or OFF
    PN-24DTA-C
    (DTI)RUN Green 120 IPM Flash Steady ON or OFF
    AIS Red OFF Steady ON
    RMT Red OFF Steady ON
    FRM Red OFF Steady ON
    PCM Red OFF Steady ON
    CRC Red OFF Steady ON 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 62  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Detection
    Application
    Processor CardsPN-30DTC-A
    (DTI)RUN Green 120 IPM Flash Steady ON or OFF
    AIS Red OFF Steady ON
    MRMT Red OFF Steady ON
    RMT Red OFF Steady ON
    MFRM Red OFF Steady ON
    FRM Red OFF Steady ON
    PCM Red OFF Steady ON
    PN-24PRT
     (PRT)RUN Green 120 IPM Flash Steady ON or OFF
    LC Green Steady ON OFF
    AIS Red OFF Steady ON
    RMT Red OFF Steady ON
    FRM Red OFF Steady ON
    PCM Red OFF Steady ON
    CRC Red OFF Steady ON
    PN-4RSTB
    (MFR)RUN Green 120 IPM Flash Steady ON or OFF
    PN-4RSTC
    (CIR)RUN Green 120 IPM Flash Steady ON or OFF
    PN-SC00 (CCH) RUN Green 120 IPM Flash Steady ON or OFF
    LC Green Steady ON OFF
    PN-SC01 (DCH) RUN Green 120 IPM Flash Steady ON or OFF
    LC Green Steady ON OFF
    PN-SC03 (ICH) RUN Green 120 IPM Flash Steady ON or OFF
    DOPE0Green Steady ON OFF
    DOPE1Green Steady ON OFF
    DOPE2Green Steady ON OFF
    DOPE3Green Steady ON OFF
    DOPE4Green Steady ON OFF
    DOPE5Green Steady ON OFF
    DOPE6Green Steady ON OFF
    DOPE7Green Steady ON OFF
    Table 2-2  Lamp Indications on Circuit Cards (Continued)
    KIND OF
    CIRCUIT CARDCARD NAMELAMP 
    NAMECOLORINDICATIONS
    NORMAL ABNORMAL 
    						