    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 83
    Lamp Indication on Cards
    This section describes the method for fault diagnosis and troubleshooting when you detect the
    fault occurrence by lamp indication on circuit cards.
    Table 2-6 shows the contents of the fault and the remedial action on each lamp status.
    Table 2-6  Remedial Action on Each Lamp Status 
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    PN-CP14 (MP) RUN lamp is not 
    flashingAbnormal 
    operation of MP 
    cardCheck the setting of SW2.
    SW2-1 : ON (in case of A-law)
    : OFF (in case of µ-law)
    SW2-4 : OFF
    Check to see if the SW3 switch 
    is set to “0” (On Line).
    If the fault cannot be cleared, 
    replace the card.
    PN-CP15 (FP) RUN lamp is not 
    flashingAbnormal 
    operation of FP 
    cardConfirm the mounting slot of the 
    FP card. (PIM2, 4, 6: Slot 12/
    PIM0: Slot 11)
    Check the setting of SENSE.
    Location of FP
          SENSE
    PIM0 0
    PIM2 1
    PIM4 2
    PIM6 3
    Reset the MB switch.
    (Down→
    Up→
    Down)
    Check to see if the BUS cable 
    between each PIM is properly 
    connected.
    If the fault cannot be cleared, 
    replace the card.
    1
    2
    3
    1
    2
    3
    4
    5 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 84  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    PN-PW00
    (EXTPWR)RUN lamp is not 
    on-48V power is not 
    being suppliedConfirm the lamp indication of 
    PZ-PW121 all lamps.
    If the fault cannot be cleared, 
    replace the PN-PW00 card.
    If PZ-PW121 lamp has abnormal 
    condition, replace the PZ-PW121 
    card.
    PZ-PW121
    (AC/DC PWR)ON lamp is not 
    onOperation power 
    is not being 
    suppliedConfirm the connection of PZ-
    PW121 and PZ-PW122.
    Turn PZ-PW122 SW switch on.
    Confirm the lamp indication of 
    PZ-PW121 all lamps.
    If the fault cannot be cleared, 
    replace the PZ-PW122 card.
    If PZ-PW121 lamp has abnormal 
    condition, replace the PZ-PW121 
    card. PZ-PW122
    (DC/DC PWR)
    PN-AP00-A
     (DBM)RUN lamp is not 
    flashingAbnormal 
    operation of DBM 
    cardConfirm the programming data: 
    CM05.
    Check to see if the SENSE switch 
    is set as per the AP Number (04-
    15) assigned by CM05.
    Reset the MB switch. 
    (Down
    →Up
    →Down)
    Check the setting of SW1.
    SW1-1: ON
    SW1-2: ON
    SW1-3: ON
    SW1-4: OFF
    If the fault cannot be cleared, 
    replace the card.
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    1
    2
    3
    4
    5
    1
    2
    3
    4
    5 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 85
    PN-AP00-B
     (AP00)RUN lamp is not 
    flashingAbnormal 
    operation of 
    AP00 cardConfirm the programming data: 
    CM05.
    Check to see if the SENSE switch 
    is set as per the AP Number (04-
    15, 20-31) assigned by CM05.
    Reset the MB switch. 
    (Down→
    Up→
    Down)
    Check the setting of SW1.
    SW1-1: ON
    SW1-2: ON
    SW1-3: ON
    If the fault cannot be cleared, 
    replace the card.
    PN-AP01 (AP01) RUN lamp is not 
    flashingAbnormal 
    operation of 
    AP01 cardConfirm the programming data: 
    CM05.
    Check to see if the SENSE switch 
    is set as per the AP Number (04-
    15) assigned by CM05.
    Reset the MB switch.
    (Down→
    Up→
    Down)
    If the fault cannot be cleared, 
    replace the card.
    PN-BRTA (BRT) RUN lamp is not 
    flashingAbnormal 
    operation of BRT 
    cardConfirm the programming data: 
    CM05, CM07 Y=02.
    Check to see if the SENS switch 
    is set as per the AP Number (04-
    15) assigned by CM05.
    Reset the MB switch.
    (Down→
    Up→
    Down)
    If the fault cannot be cleared, 
    replace the card.
    ALM lamp is on Transmission line 
    faultConfirm circuit line status.
    Confirm PSTN line status.
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    4
    5
    1
    2
    3
    4
    1
    2
    3
    4
    1
    2 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 86  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    PN-2BRTC
    (BRT)RUN lamp is not 
    flashingAbnormal 
    operation of BRT 
    cardConfirm the programming data: 
    CM05.
    Check to see if the SENSE switch 
    is set as per the AP Number (04-
    15, 20-31) assigned by CM05, 
    CM07 Y=2.
    Reset the MB switch.
    (Down
    →Up
    →Down)
    If the fault cannot be cleared, 
    replace the card.
    ALM0 lamp is on No.0 circuit 
    transmission line 
    faultConfirm No.0 circuit line status.
    Confirm PSTN line status.
    ALM1 lamp is on No.1 circuit 
    transmission line 
    faultConfirm No.1 circuit line status.
    Confirm PSTN line status.
    PN-CC01
    (ETHER)RUN lamp is not 
    flashingAbnormal 
    operation of 
    ETHER cardReplace the ETHER card.
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    4
    1
    2
    1
    2 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 87
    PN-24DTA-C
    (DTI)RUN lamp is not 
    flashingAbnormal 
    operation of DTI 
    cardConfirm the programming data: 
    CM05, CM07 Y=01.
    Check to see if the SENS switch 
    is set as per the AP Number (04-
    15, 20-31) assigned by CM05.
    Reset the MB switch.
    (Down→
    Up→
    Down)
    If the fault cannot be cleared, 
    replace the card.
    CRC lamp is on Bit Error Rate 
    exceeds the 
    predetermined 
    valueCheck the receive line and exter-
    nal equipment.
    Replace the remote DTI card.
    PCM lamp is on No PCM signals 
    arrive from the 
    distant officeCheck to see if the DTI cable is 
    correctly connected.
    Plug and unplug the DTI card.
    Repeat this step two or three 
    times.
    FRM lamp is on Frame Alignment 
    signals from the 
    distant office can-
    not be receivedCheck the receive line and exter-
    nal equipment.
    Replace the remote DTI card.
    RMT lamp is on Frame Alignment 
    signals cannot be 
    sent to the 
    remote PBXCheck the transmission line and 
    external equipment.
    Replace the DTI card.
    AIS lamp is on Remote PBX is in 
    the loop-back testCheck the switch settings of the 
    remote DTI card.
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    4
    1
    2
    1
    2
    1
    2
    1
    2 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 88  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    PN-30DTC-A
    (DTI)RUN lamp is not 
    flashingAbnormal 
    operation of DTI 
    cardConfirm the programming data: 
    CM05, CM07 Y=01.
    Check to see if the SENS switch 
    is set as per the AP Number (04-
    15, 20-31) assigned by CM05.
    Reset the MB switch.
    (Down
    →Up
    →Down)
    If the fault cannot be cleared, 
    replace the card.
    PCM lamp is on No PCM signals 
    arrive from the 
    distant officeCheck to see if the DTI cable is 
    correctly connected.
    Plug and unplug the DTI card.
    Repeat this step two or three 
    times.
    FRM lamp is on Frame Alignment 
    signals from the 
    distant office can-
    not be receivedCheck the receive line and exter-
    nal equipment.
    Replace the DTI card.
    MFRM lamp is 
    onMulti Frame 
    Alignment signals 
    from the distant 
    office cannot be 
    receivedCheck the receive line and exter-
    nal equipment.
    Replace the DTI card.
    RMT lamp is on Frame Alignment 
    signals cannot be 
    sent to the 
    remote PBXCheck the transmission line and 
    external equipment.
    Replace the DTI card.
    MRMT lamp is 
    onFrame Alignment 
    signals from the 
    distant office can-
    not be receivedConfirm the switch setting on the 
    DTI board indicating an alarm.
    Replace the DTI card not indicat-
    ing an alarm, with a spare.
    AIS lamp is on Remote PBX is in 
    the loop-back testCheck the switch settings of the 
    remote DTI card.
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    4
    1
    2
    1
    2
    1
    2
    1
    2
    1
    2 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 89
    PN-24PRT
    (PRT)RUN lamp is not 
    flashingAbnormal 
    operation of PRT 
    cardConfirm the programming data: 
    CM05, CM07 Y=01.
    Check to see if the SENS switch 
    is set as per the AP Number (04-
    15, 20-31) assigned by CM05.
    Reset the MB switch.
    (Down→
    Up→
    Down)
    If the fault cannot be cleared, 
    replace the card.
    LC lamp is not 
    onISDN primary 
    rate D-channel 
    data link 
    connection failureCheck the status of the local-office 
    side line or the public network side 
    line.
    CRC lamp is on Bit Error Rate 
    exceeds the 
    predetermined 
    valueCheck the receive line and exter-
    nal equipment.
    Replace the remote PRT card.
    PCM lamp is on No PCM signals 
    arrive from the 
    distant officeCheck to see if the PRT cable is 
    correctly connected.
    Plug and unplug the PRT card.
    Repeat this step two or three 
    times.
    FRM lamp is on Frame Alignment 
    signals from the 
    distant office can-
    not be receivedCheck the receive line and exter-
    nal equipment.
    Replace the remote PRT card.
    RMT lamp is on Frame Alignment 
    signals cannot be 
    sent to the 
    remote PBXCheck the transmission line and 
    external equipment.
    Replace the PRT card.
    AIS lamp is on Remote PBX is in 
    the loop-back testCheck the switch settings of the 
    remote PRT card.
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    4
    1
    2
    1
    2
    1
    2
    1
    2 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 90  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    PN-4RSTB
    (MFR)RUN lamp is not 
    flashingAbnormal 
    operation of MFR 
    cardConfirm the programming data: 
    CM05.
    Check to see if the SENSE switch 
    is set as per the AP Number (04-
    15, 20-31) assigned by CM05.
    Reset the MB switch.
    (Down
    →Up
    →Down)
    If the fault cannot be cleared, 
    replace the card.
    PN-4RSTC
    (CIR)RUN lamp is not 
    flashingAbnormal 
    operation of CIR 
    cardConfirm the programming data: 
    CM05.
    Check to see if the SENSE switch 
    is set as per the AP Number (04-
    15) assigned by CM05.
    Reset the MB switch.
    (Down
    →Up
    →Down)
    If the fault cannot be cleared, 
    replace the card.
    PN-SC00 (CCH) RUN lamp is not 
    flashingAbnormal 
    operation of CCH 
    cardConfirm the programming data: 
    CM05.
    Check to see if the SENS switch 
    is set as per the AP Number (04-
    15, 20-31) assigned by CM05.
    Reset the MB switch.
    (Down
    →Up
    →Down)
    If the fault cannot be cleared, 
    replace the card.
    LC lamp is not 
    onCCH link 
    connection failureCheck the status of the local-office 
    side line or the remote-office side 
    line.
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    4
    1
    2
    3
    4
    1
    2
    3
    4 
    						
    							CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 91
    PN-SC01 (DCH) RUN lamp is not 
    flashingAbnormal opera-
    tion of DCH cardConfirm the programming data: 
    CM05.
    Check to see if the SENS switch 
    is set as per the AP Number (04-
    15, 20-31) assigned by CM05.
    Reset the MB switch.
    (Down→
    Up→
    Down)
    If the fault cannot be cleared, 
    replace the card.
    LC lamp is not 
    onDCH D-channel 
    link connection 
    failureCheck the status of the local-office 
    side line or the public network side 
    line.
    PN-SC03
    (ICH)RUN lamp is not 
    flashingAbnormal opera-
    tion of ICH cardConfirm the programming data: 
    CM05.
    After confirmation of CM05, reset 
    the system (Push the SW1 of 
    MP).
    Check to see if the SENS switch 
    is set as per the AP Number (04-
    15, 20-31) assigned by CM05. 
    Reset the MB switch.
    (Down→
    Up→
    Down)
    If the fault cannot be cleared, 
    replace the card.
    DOPE lamp is 
    not onD channel link is 
    not connected 
    between ICH and 
    ILCConfirm the programming data: 
    CM06.
    Confirm if the corresponding ILC 
    card is removed.
    If the fault cannot be cleared, 
    replace the card.   
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    4
    1
    2
    3
    4
    5
    1
    2
    3 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 92  ND-70926 (E), Issue 1.0
    CHAPTER 2  TROUBLESHOOTING
    Fault Diagnosis and Troubleshooting
    PN-SC03-A
    (CSH)RUN lamp is not 
    flashingAbnormal opera-
    tion of CSH cardConfirm the programming data: 
    CM05.
    After confirmation of CM05, reset 
    the system (Push the SW1 of 
    MP).
    Check to see if the SENS switch 
    is set as per the AP Number (04-
    15, 20-31) assigned by CM05. 
    Reset the MB switch.
    (Down
    →Up
    →Down)
    If the fault cannot be cleared, 
    replace the card.
    DOPE lamp is 
    not onD channel link is 
    not connected 
    between CSH 
    and CSIConfirm the programming data: 
    CM06 Y=10
    Confirm if the corresponding CSI 
    card is removed.
    If the fault cannot be cleared, 
    replace the card.   
    PN-2COTD 
    (COT)
    [For Australia/
    Others]LF lamp is on Transmission line 
    faultSearch for a line fault by CMB0 
    Y=1 or CMF5 Y=0.
    Check to see if the trunk line is 
    faulty. 
    PN-4COTE 
    (COT)
    [For Australia]LF lamp is on Transmission line 
    faultSearch for a line fault by CMB0 
    Y=1 or CMF5 Y=0.
    Check to see if the trunk line is 
    faulty.
    PN-6COTJ 
    (COT)
    [For Australia]LF lamp is on Transmission line 
    faultSearch for a line fault by CMB0 
    Y=1 or CMF5 Y=0.
    Check to see if the trunk line is 
    faulty.
    PN-8COTT 
    (COT)
    [For Australia]LF lamp is on Transmission line 
    faultSearch for a line fault by CMB0 
    Y=1 or CMF5 Y=0.
    Check to see if the trunk line is 
    faulty.
    Table 2-6  Remedial Action on Each Lamp Status (Continued)
    CARD NAME LAMP STATUSFAU LT
    CONTENTREMEDIAL ACTION
    1
    2
    3
    4
    5
    1
    2
    3
    1
    2
    1
    2
    1
    2
    1
    2 
    						