CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 83 Lamp Indication on Cards This section describes the method for fault diagnosis and troubleshooting when you detect the fault occurrence by lamp indication on circuit cards. Table 2-6 shows the contents of the fault and the remedial action on each lamp status. Table 2-6 Remedial Action on Each Lamp Status CARD NAME LAMP STATUSFAU LT CONTENTREMEDIAL ACTION PN-CP14 (MP) RUN lamp is not flashingAbnormal operation of MP cardCheck the setting of SW2. SW2-1 : ON (in case of A-law) : OFF (in case of µ-law) SW2-4 : OFF Check to see if the SW3 switch is set to “0” (On Line). If the fault cannot be cleared, replace the card. PN-CP15 (FP) RUN lamp is not flashingAbnormal operation of FP cardConfirm the mounting slot of the FP card. (PIM2, 4, 6: Slot 12/ PIM0: Slot 11) Check the setting of SENSE. Location of FP SENSE PIM0 0 PIM2 1 PIM4 2 PIM6 3 Reset the MB switch. (Down→ Up→ Down) Check to see if the BUS cable between each PIM is properly connected. If the fault cannot be cleared, replace the card. 1 2 3 1 2 3 4 5
NEAX2000 IVS2 Maintenance ManualPage 84 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting PN-PW00 (EXTPWR)RUN lamp is not on-48V power is not being suppliedConfirm the lamp indication of PZ-PW121 all lamps. If the fault cannot be cleared, replace the PN-PW00 card. If PZ-PW121 lamp has abnormal condition, replace the PZ-PW121 card. PZ-PW121 (AC/DC PWR)ON lamp is not onOperation power is not being suppliedConfirm the connection of PZ- PW121 and PZ-PW122. Turn PZ-PW122 SW switch on. Confirm the lamp indication of PZ-PW121 all lamps. If the fault cannot be cleared, replace the PZ-PW122 card. If PZ-PW121 lamp has abnormal condition, replace the PZ-PW121 card. PZ-PW122 (DC/DC PWR) PN-AP00-A (DBM)RUN lamp is not flashingAbnormal operation of DBM cardConfirm the programming data: CM05. Check to see if the SENSE switch is set as per the AP Number (04- 15) assigned by CM05. Reset the MB switch. (Down →Up →Down) Check the setting of SW1. SW1-1: ON SW1-2: ON SW1-3: ON SW1-4: OFF If the fault cannot be cleared, replace the card. Table 2-6 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUSFAU LT CONTENTREMEDIAL ACTION 1 2 3 1 2 3 4 5 1 2 3 4 5
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 85 PN-AP00-B (AP00)RUN lamp is not flashingAbnormal operation of AP00 cardConfirm the programming data: CM05. Check to see if the SENSE switch is set as per the AP Number (04- 15, 20-31) assigned by CM05. Reset the MB switch. (Down→ Up→ Down) Check the setting of SW1. SW1-1: ON SW1-2: ON SW1-3: ON If the fault cannot be cleared, replace the card. PN-AP01 (AP01) RUN lamp is not flashingAbnormal operation of AP01 cardConfirm the programming data: CM05. Check to see if the SENSE switch is set as per the AP Number (04- 15) assigned by CM05. Reset the MB switch. (Down→ Up→ Down) If the fault cannot be cleared, replace the card. PN-BRTA (BRT) RUN lamp is not flashingAbnormal operation of BRT cardConfirm the programming data: CM05, CM07 Y=02. Check to see if the SENS switch is set as per the AP Number (04- 15) assigned by CM05. Reset the MB switch. (Down→ Up→ Down) If the fault cannot be cleared, replace the card. ALM lamp is on Transmission line faultConfirm circuit line status. Confirm PSTN line status. Table 2-6 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUSFAU LT CONTENTREMEDIAL ACTION 1 2 3 4 5 1 2 3 4 1 2 3 4 1 2
NEAX2000 IVS2 Maintenance ManualPage 86 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting PN-2BRTC (BRT)RUN lamp is not flashingAbnormal operation of BRT cardConfirm the programming data: CM05. Check to see if the SENSE switch is set as per the AP Number (04- 15, 20-31) assigned by CM05, CM07 Y=2. Reset the MB switch. (Down →Up →Down) If the fault cannot be cleared, replace the card. ALM0 lamp is on No.0 circuit transmission line faultConfirm No.0 circuit line status. Confirm PSTN line status. ALM1 lamp is on No.1 circuit transmission line faultConfirm No.1 circuit line status. Confirm PSTN line status. PN-CC01 (ETHER)RUN lamp is not flashingAbnormal operation of ETHER cardReplace the ETHER card. Table 2-6 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUSFAU LT CONTENTREMEDIAL ACTION 1 2 3 4 1 2 1 2
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 87 PN-24DTA-C (DTI)RUN lamp is not flashingAbnormal operation of DTI cardConfirm the programming data: CM05, CM07 Y=01. Check to see if the SENS switch is set as per the AP Number (04- 15, 20-31) assigned by CM05. Reset the MB switch. (Down→ Up→ Down) If the fault cannot be cleared, replace the card. CRC lamp is on Bit Error Rate exceeds the predetermined valueCheck the receive line and exter- nal equipment. Replace the remote DTI card. PCM lamp is on No PCM signals arrive from the distant officeCheck to see if the DTI cable is correctly connected. Plug and unplug the DTI card. Repeat this step two or three times. FRM lamp is on Frame Alignment signals from the distant office can- not be receivedCheck the receive line and exter- nal equipment. Replace the remote DTI card. RMT lamp is on Frame Alignment signals cannot be sent to the remote PBXCheck the transmission line and external equipment. Replace the DTI card. AIS lamp is on Remote PBX is in the loop-back testCheck the switch settings of the remote DTI card. Table 2-6 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUSFAU LT CONTENTREMEDIAL ACTION 1 2 3 4 1 2 1 2 1 2 1 2
NEAX2000 IVS2 Maintenance ManualPage 88 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting PN-30DTC-A (DTI)RUN lamp is not flashingAbnormal operation of DTI cardConfirm the programming data: CM05, CM07 Y=01. Check to see if the SENS switch is set as per the AP Number (04- 15, 20-31) assigned by CM05. Reset the MB switch. (Down →Up →Down) If the fault cannot be cleared, replace the card. PCM lamp is on No PCM signals arrive from the distant officeCheck to see if the DTI cable is correctly connected. Plug and unplug the DTI card. Repeat this step two or three times. FRM lamp is on Frame Alignment signals from the distant office can- not be receivedCheck the receive line and exter- nal equipment. Replace the DTI card. MFRM lamp is onMulti Frame Alignment signals from the distant office cannot be receivedCheck the receive line and exter- nal equipment. Replace the DTI card. RMT lamp is on Frame Alignment signals cannot be sent to the remote PBXCheck the transmission line and external equipment. Replace the DTI card. MRMT lamp is onFrame Alignment signals from the distant office can- not be receivedConfirm the switch setting on the DTI board indicating an alarm. Replace the DTI card not indicat- ing an alarm, with a spare. AIS lamp is on Remote PBX is in the loop-back testCheck the switch settings of the remote DTI card. Table 2-6 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUSFAU LT CONTENTREMEDIAL ACTION 1 2 3 4 1 2 1 2 1 2 1 2 1 2
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 89 PN-24PRT (PRT)RUN lamp is not flashingAbnormal operation of PRT cardConfirm the programming data: CM05, CM07 Y=01. Check to see if the SENS switch is set as per the AP Number (04- 15, 20-31) assigned by CM05. Reset the MB switch. (Down→ Up→ Down) If the fault cannot be cleared, replace the card. LC lamp is not onISDN primary rate D-channel data link connection failureCheck the status of the local-office side line or the public network side line. CRC lamp is on Bit Error Rate exceeds the predetermined valueCheck the receive line and exter- nal equipment. Replace the remote PRT card. PCM lamp is on No PCM signals arrive from the distant officeCheck to see if the PRT cable is correctly connected. Plug and unplug the PRT card. Repeat this step two or three times. FRM lamp is on Frame Alignment signals from the distant office can- not be receivedCheck the receive line and exter- nal equipment. Replace the remote PRT card. RMT lamp is on Frame Alignment signals cannot be sent to the remote PBXCheck the transmission line and external equipment. Replace the PRT card. AIS lamp is on Remote PBX is in the loop-back testCheck the switch settings of the remote PRT card. Table 2-6 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUSFAU LT CONTENTREMEDIAL ACTION 1 2 3 4 1 2 1 2 1 2 1 2
NEAX2000 IVS2 Maintenance ManualPage 90 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting PN-4RSTB (MFR)RUN lamp is not flashingAbnormal operation of MFR cardConfirm the programming data: CM05. Check to see if the SENSE switch is set as per the AP Number (04- 15, 20-31) assigned by CM05. Reset the MB switch. (Down →Up →Down) If the fault cannot be cleared, replace the card. PN-4RSTC (CIR)RUN lamp is not flashingAbnormal operation of CIR cardConfirm the programming data: CM05. Check to see if the SENSE switch is set as per the AP Number (04- 15) assigned by CM05. Reset the MB switch. (Down →Up →Down) If the fault cannot be cleared, replace the card. PN-SC00 (CCH) RUN lamp is not flashingAbnormal operation of CCH cardConfirm the programming data: CM05. Check to see if the SENS switch is set as per the AP Number (04- 15, 20-31) assigned by CM05. Reset the MB switch. (Down →Up →Down) If the fault cannot be cleared, replace the card. LC lamp is not onCCH link connection failureCheck the status of the local-office side line or the remote-office side line. Table 2-6 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUSFAU LT CONTENTREMEDIAL ACTION 1 2 3 4 1 2 3 4 1 2 3 4
CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 91 PN-SC01 (DCH) RUN lamp is not flashingAbnormal opera- tion of DCH cardConfirm the programming data: CM05. Check to see if the SENS switch is set as per the AP Number (04- 15, 20-31) assigned by CM05. Reset the MB switch. (Down→ Up→ Down) If the fault cannot be cleared, replace the card. LC lamp is not onDCH D-channel link connection failureCheck the status of the local-office side line or the public network side line. PN-SC03 (ICH)RUN lamp is not flashingAbnormal opera- tion of ICH cardConfirm the programming data: CM05. After confirmation of CM05, reset the system (Push the SW1 of MP). Check to see if the SENS switch is set as per the AP Number (04- 15, 20-31) assigned by CM05. Reset the MB switch. (Down→ Up→ Down) If the fault cannot be cleared, replace the card. DOPE lamp is not onD channel link is not connected between ICH and ILCConfirm the programming data: CM06. Confirm if the corresponding ILC card is removed. If the fault cannot be cleared, replace the card. Table 2-6 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUSFAU LT CONTENTREMEDIAL ACTION 1 2 3 4 1 2 3 4 5 1 2 3
NEAX2000 IVS2 Maintenance ManualPage 92 ND-70926 (E), Issue 1.0 CHAPTER 2 TROUBLESHOOTING Fault Diagnosis and Troubleshooting PN-SC03-A (CSH)RUN lamp is not flashingAbnormal opera- tion of CSH cardConfirm the programming data: CM05. After confirmation of CM05, reset the system (Push the SW1 of MP). Check to see if the SENS switch is set as per the AP Number (04- 15, 20-31) assigned by CM05. Reset the MB switch. (Down →Up →Down) If the fault cannot be cleared, replace the card. DOPE lamp is not onD channel link is not connected between CSH and CSIConfirm the programming data: CM06 Y=10 Confirm if the corresponding CSI card is removed. If the fault cannot be cleared, replace the card. PN-2COTD (COT) [For Australia/ Others]LF lamp is on Transmission line faultSearch for a line fault by CMB0 Y=1 or CMF5 Y=0. Check to see if the trunk line is faulty. PN-4COTE (COT) [For Australia]LF lamp is on Transmission line faultSearch for a line fault by CMB0 Y=1 or CMF5 Y=0. Check to see if the trunk line is faulty. PN-6COTJ (COT) [For Australia]LF lamp is on Transmission line faultSearch for a line fault by CMB0 Y=1 or CMF5 Y=0. Check to see if the trunk line is faulty. PN-8COTT (COT) [For Australia]LF lamp is on Transmission line faultSearch for a line fault by CMB0 Y=1 or CMF5 Y=0. Check to see if the trunk line is faulty. Table 2-6 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUSFAU LT CONTENTREMEDIAL ACTION 1 2 3 4 5 1 2 3 1 2 1 2 1 2 1 2