    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Station Line Status Display
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 33
    Analog Line/Digital Line
    00: LC (Single Line Telephone)
    10: DLC (D
    term)
    Hardware Test
    See Ta b l e  1 - 9.
    Software Test
    01 - FF:  See Table 1-10. (This data is the same as the status code of CMF5.)
    Table 1-9  Status of Single Line Telephone and Dterm
    INDICATIONSTATUS OF SINGLE 
    LINE TELEPHONESTATUS OF DtermREMARKS
    00 Terminal is not connected. Terminal is not connected, or
    Tip wire is grounded.
    01 Terminal is connected. Terminal is connected.
    02 Loop (Shor t circuit is made
    on the line.)Short circuit is made on the
    line.
    03 Ring wire is grounded Ring wire is grounded.
    04 LC card is not mounted. DLC card is not mounted.
    05 Test busy Terminal Failure
    06–DLC card down
    07––
    08–Line failure detected
    2
    3
    4 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 34  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Battery Release Control
    BATTERY RELEASE CONTROL
    General Description
    When the AC power is to be cut off intentionally (such as maintenance for the building), this fea-
    ture can disconnect the batteries from the PBX, using the MAT or the CAT, and prevent an exces-
    sive discharge of the battery.
    Figure 1-1  System Diagram of Battery Release Control
    Service Conditions
    The battery disconnection is canceled if the system is initialized (Power off/on or Reset).
    Programming Procedure
    No programming is required.
    MAT MODEM C.O.
    NETWORK
    ENTERING COMMAND PBX
    MODEM
    MP
    BATTERY CONNECTION RELAYPWR
    BATTERY 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Battery Release Control
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 35
    Operating Procedure
    (1) To disconnect the battery
    (2) To cancel the battery disconnection
    DE
    +EC0>
    EC0
    STCOMMAND=
    DE
    +EC0>00:1 –
    00
    EXE
    +EC0>00:1 – 0
    0
    OK
    The current status displays after entering first data 00
    (1: Battery connection)
    The status changes to battery disconnection after
    entering second data 0.
    DE
    +EC0>
    EC0
    STCOMMAND=
    DE
    +EC0>00:0 –
    00
    EXE
    +EC0>00:0 – 1
    1
    OK
    The current status displays after entering first data 00
    (0: Battery disconnection)
    The status changes to battery connection after entering
    second data 1. 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 36  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Station/Trunk Status Display
    STATION/TRUNK STATUS DISPLAY
    General Description
    This feature allows station/trunk connection status to be displayed on the MAT. If the status is ab-
    normal, this feature can forcibly release the connection using the MOC Terminal feature of MAT-
    WorX or the CAT.
    Service Conditions
    (1) Printout of connection status or execution report of forced release is available through the 
    printer connected to the MAT.
    (2) This feature is available for the following items:
      Trunk number (analog trunks)
     Station number
    Virtual station number (Except for Intercom/Attendant position loop line.)
    (3) The MAT continues to scan and update the latest connection status on the screen on a real-
    time basis. 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Station/Trunk Status Display
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 37
    Programming Procedure
    No programming is required.
    Operating Procedure
    (1) To display Station/Trunk Status:
    Refer to the MATWorX Studio User’s Guide.
    (2) To forcibly release the station/trunk connection:
    Operation:
    DE
    +EB0>
    EB0
    STCOMMAND=
    DE
    +XXX : CCC
    DXXX
    (Trunk No.)
    Trunk No.
    DE
    +EB2>
    EB2
    STCOMMAND=
    DE
    +XXXXXXXX : CCC
    X-XXXXXXXX
    (Station No.)
    FX-FXXXXXXXX
    (D
    term No.)
    Station No. 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 38  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Diagnostics
    DIAGNOSTICS
    General Description
    To assist maintenance personnel, this feature provides diagnostic capabilities such as fault code
    generation, device status information and alarm information recording, which can be accessed
    from the MAT or the CAT.
    Service Conditions
    (1) The following station status information can be displayed on the MAT or the CAT by direct 
    command:
    Idle
    Line Lockout
    Dialing
    Tone Trunk Connection (reorder tone, busy tone, service set tone, etc.)
    Types of Connection (station-to-station, three-way calling, voice calling, holding, etc.)
    Destination number (trunk number, register number)
    Short circuit on line
    (2) The following trunk status information can be displayed on the MAT or the CAT by direct 
    command:
    Idle
    Ringing in
    Incoming queue to Attendant Console
    Holding
    In a tandem connection
    Incoming queue to UCD
    Dialing
    Receiving dialed digits 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Diagnostics
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 39
    (3) The following information is stored and can be displayed on the MAT or the CAT using a 
    memory dump command in hexadecimal format: 
    Program address where an endless loop has occurred
    Last initialization time for main program
    Last initialization time for firmware program
    The reason for initialization (power-on, RESET
     key, endless loop, rotary switch, command 
    from MAT or CAT)
    (4) The PBX has a built-in patrol program that monitors the status of all connected devices. 
    Additionally, when no response or an invalid response from a device is received, this 
    program stores in memory the slot number of that device. From the MAT or the CAT, a 
    maintenance person can read the slot number of any device that does not respond to the 
    main processor or provides an illegal status to the main processor.
    Programming Procedure
    No programming is required.
    Operating Procedure
    (1) Station Status Information
    Operation:
    For the meaning of status code, see Table 1-10.
    DE
    +F50>
    F50
    STCOMMAND=
    DE
    +XXXX : XX XX XX XX
    0 + X-XXXXXXXX
    (Station No.)
    or
    0 + FX-FXXXXXXXX
    (D
    term No.)Status Code of the designated Address +3
    Status Code of the designated Address +2
    Status Code of the designated Address +1
    Status Code of the designated Address
    Designated Address 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 40  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Diagnostics
    Table 1-10  Station Status Information 
    STATUS 
    CODEDESCRIPTION REMARKS
    01 Idle
    02 In Line Lockout mode
    10 Dialing to an ORT
    11 Dialing to a trunk
    12 Dialing to an ORT (After consultation hold a station)
    13 Dialing to an ORT (After consultation hold a trunk)
    14 Dialing to a trunk (After consultation hold a station)
    15 Dialing to a trunk (After consultation hold a trunk)
    1F Dialing to an ORT (After consultation hold 3 par ty Confer-
    ence Trunk)
    20 In Reorder Tone connection
    21 In Reorder Tone connection (While consultation hold a 
    Station)
    22 In Reorder Tone connection (While consultation hold a trunk)
    23 In Reorder Tone connection (While consultation hold 3 party 
    Conference Trunk)
    2C In Howler Tone connection
    30 In Service Set tone connection
    32 In Service Set tone connection (While consultation hold a
    trunk)
    40 In Ringback Tone Connection
    41 In Ringback Tone Connection for the second call
    (After consultation hold a station)
    42 In Ringback Tone connection for the second call 
    (After consultation hold a trunk)
    44 In Ringback Tone connection for the operator call
    45 In Ringback Tone connection for operator call
    (After consultation hold a station) 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Diagnostics
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 41
    NOTE:
    The status codes not described in this table mean busy conditions. 46 In Ringback Tone connection for operator call 
    (After consultation hold a trunk)
    50 Ringing (Call from a station)
    51 Ringing (Call from an outside party)
    55 Ringing (Automatic Wake Up Call)
    60 In Station to Station connection
    62 In 3 Way Calling
    65 Holding
    66
    Voice Call to a D
    term
    67 Voice Call from a Station
    71 In Station to Trunk connection
    72 Three-way calling with a station and a trunk
    C4
    In a CAT mode (For D
    term)
    C8 In a UCD Queue
    C9 In a UCD Queue after holding a station
    CA In a UCD Queue after holding a trunk
    Table 1-10  Station Status Information (Continued)
    STATUS 
    CODEDESCRIPTION REMARKS 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 42  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Diagnostics
    (2) Trunk Status Information
    Operation:
    For the meaning of status code, see Table 1-11.
    DE
    +F50>
    F50
    STCOMMAND=
    DE
    +XXXX : XX XX XX XX
    0 + DXXX
    (Trunk No.)
    Status Code of the designated Address +3
    Status Code of the designated Address +2
    Status Code of the designated Address +1
    Status Code of the designated Address
    Designated Address 
    						
    All NEC manuals Comments (0)