    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 23
    (2) To Clear MJ/MN Alarm
    
    To clear both MJ/MN alarms
    Operation:
    
    To clear MJ alarm only
    Operation:
    
    To clear MN alarm only
    Operation:
    DE
    +EA1>
    EA1
    STCOMMAND=
    DE
    +EA1>00:00 –
    00
    EXE
    +OK
    CCC
    DE
    +EA1>
    EA1
    STCOMMAND=
    DE
    +EA1>01:01 –
    01
    EXE
    +OK
    CCC
    DE
    +EA1>
    EA1
    STCOMMAND=
    DE
    +EA1>02:02 –
    02
    EXE
    +OK
    CCC 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 24  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    (3) To Display Fault Messages using MATWorX Studio
    Refer to the MATWorX Studio User’s Guide or to the Fault Display online Help in the 
    MATWorX Studio to display fault messages.
    Table 1-5 provides an explanation of the 8-byte data that appears in the Description column. 
    Table 1-7 shows examples of fault occurrence messages and Ta b l e  1 - 8 shows examples of 
    fault restoration information that the Fault Display add-in may display. 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 25
    Table 1-7  Examples of Fault Occurrence Display Using MATWorX 
    Fault Alarm Date CPU Description
    01 - 99/01/08 13:26 MP System initialization
    Type : Power On Initialize
    Data = (F0 FF FF FF FF FF FF FF)
    01 - 99/01/08 13:26 MP System initialization
    Type : Initialize by Reset Button (SW1)
    Data = (F1 FF FF FF FF FF FF FF)
    01 MJ 99/01/08 13:26 MP System initialization
    Type : Serious failure 1
    Data = (12 23 45 67 89 FF FF FF)
    01 MJ 99/01/08 13:26 MP System initialization
    Type : Serious failure 2
    Data = (13 34 56 78 9A FF FF FF)
    01 MJ 99/01/08 13:26 MP System initialization
    Type : Serious failure 3
    Data = (F5 FF FF FF FF FF FF FF)
    01 MJ 99/01/08 13:26 MP System initialization
    Type : Serious failure 4
    Data = (16 67 89 AB CD FF FF FF)
    01 MJ 99/01/08 13:26 MP System initialization
    Type : Serious failure 5
    Data = (F7 FF FF FF FF FF FF FF)
    01 MJ 99/01/08 13:26 MP System initialization
    Type : Serious failure 6
    Data = (F8 FF FF FF FF FF FF FF)
    01 - 99/01/08 13:26 MP System initialization
    Type : SW3 Switch was changed to 0
    Data = (F9 FF FF FF FF FF FF FF)
    01 MJ 99/01/08 13:26 MP System initialization
    Type : Serious failure 7
    Data = (2A 11 22 33 44 FF FF FF)
    01 - 99/01/08 13:26 MP System initialization
    Type : Initialize by CAT or MAT
    Data = (FB FF FF FF FF FF FF FF)
    01 MJ 99/01/08 13:26 MP System initialization
    Type : switching
    Data = (FC FF FF FF FF FF FF FF)
    03 MN 99/01/08 13:26 MP The number of hopper entry was more than the caution level
    Hopper kind = H-rank
    Data = (F0 FF FF FF FF FF FF FF)
    03 MN 99/01/08 13:26 MP The number of hopper entry was more than the caution level
    Hopper kind = L-rank
    Data = (F1 FF FF FF FF FF FF FF) 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 26  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    04 MN 99/01/08 13:26 MP MP-FP/AP communication failure
    Overflow of data sending buffer to FP/AP. (Count = 10 FP/AP NO. = 04)
    Data = (F0 0A 04 FF FF FF FF FF)
    04 MN 99/01/08 13:26 MP MP-FP/AP communication failure
    Invalid data received from FP/AP. (Count = 96 FP/AP NO. = 07)
    Data = (F1 60 07 FF FF FF FF FF)
    04 MN 99/01/08 13:26 MP MP-FP/AP communication failure
    Invalid data received from FP/AP. (Count = 100 or more FP/AP NO. =
    11)
    Data = (F1 FF 0B FF FF FF FF FF)
    08 MN 99/01/08 13:26 MP FP/AP card down
    (FP/AP NO. = 52)
    Data = (F4 FF FF FF FF FF FF FF)
    09 MJ 99/01/08 13:26 MP Power failure
    Power Failure Kind : AC input failure
    Data = (00 01 02 FF FF FF FF FF)
    09 MJ 99/01/08 13:26 MP Power failure
    Power Failure Kind : Fuse break
    Data = (01 02 00 FF FF FF FF FF)
    09 MJ 99/01/08 13:26 MP Power failure
    Power Failure Kind : PWR alarm
    Data = (02 00 01 FF FF FF FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : Fault notice from CS/ZT (CS/ZT No. = 10)
    Data = (00 04 00 10 31 01 FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT initial failure (CS/ZT No. = 10)
    Data = (01 04 00 10 31 01 FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT condition read failure (CS/ZT No. = 10)
    Data = (02 04 00 10 31 01 FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT condition unmatch (CS/ZT No. = 10)
    Data = (03 04 00 10 31 01 FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : Bch condition unmatch (CS/ZT No. = 10)
    Data = (04 04 00 10 31 01 FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : SYS-ID upload failure (CS/ZT No. = 10)
    Data = (05 04 00 10 31 01 FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : SYS-ID download failure (CS/ZT No. = 10)
    Data = (06 04 00 10 31 01 FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT make busy failure (CS/ZT No. = 10)
    Data = (07 04 00 10 31 FF FF FF)
    Table 1-7  Examples of Fault Occurrence Display Using MATWorX (Continued)
    Fault Alarm Date CPU Description 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 27
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT data load failure (CS/ZT No. = 10)
    Data = (08 04 00 10 31 FF FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : Bch make busy failure (CS/ZT No. = 10)
    Data = (09 04 00 10 31 FF FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT operation parameter change failure (CS/ZT No. = 0)
    Data = (0A FF FF 10 31 FF FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : LCCH sending position failure (CS/ZT No. = 0)
    Data = (0B FF FF 10 31 FF FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : Carrier selection failure (CS/ZT No. = 0)
    Data = (0C FF FF 10 31 FF FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT expansion  data read failure (CS/ZT No. = 0)
    Data = (0D 01 FF 10 31 FF FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT expansion data setting failure (CS/ZT No. = 0)
    Data = (0E FF FF 10 31 FF FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT operation parameter 2 change failure (CS/ZT No. =
    0)
    Data = (0F FF FF 10 31 FF FF FF)
    12 MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : (CS/ZT No. = 0)
    Data = (10 FF FF 10 31 FF FF FF)
    16 MN 99/01/08 19:30 MP It is a day for periodic maintenance
    Battery check (TK = 0)
    Data = (F8 FF FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    PCM loss
    Data = (F0 FF FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    Frame  lo ss
    Data = (F1 FF FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    Multi frame loss
    Data = (F2 FF FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    AIS error
    Data = (F3 FF FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    Remote alarm
    Data = (F4 FF FF FF FF FF FF FF)
    Table 1-7  Examples of Fault Occurrence Display Using MATWorX (Continued)
    Fault Alarm Date CPU Description 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 28  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    Multi remote alarm
    Data = (F5 FF FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    S-bit error
    Data = (F6 FF FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    CRC error
    Data = (F8 FF FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    Slip detected
    Data = (F9 FF FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    Main signal all 1
    Data = (FA 01 FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    INFO 0
    Data = (FB FF FF FF FF FF FF FF)
    20 MJ 99/01/08 13:28 AP 5 DTI line failure
    INFO 2
    Data = (FC FF FF FF FF FF FF FF)
    21 MN 99/01/08 13:28 AP 6 DCH/BRT/PRT D-channel link connection failure
    (D-ch NO. = 3)
    Data = (03 FF FF FF FF FF FF FF)
    22 MN 99/01/08 13:28 AP 7 CCH link connection failure
    (CCH NO.  = 3)
    Data = (03 FF FF FF FF FF FF FF)
    24 MN 99/01/08 13:26 FP 0 Number of faulty trunks was more than predetermined number
    Data = (FF FF FF FF FF FF FF FF)
    25 MN 99/01/08 13:26 MP Number of lockout stations was more than predetermined number
    Data = (FF FF FF FF FF FF FF FF)
    26 MN 99/01/08 13:28 FP 1 DLC card down
    DLC Failure Kind : Terminal was cut off (Station number = 2000)
    Data = (00 00 80 20 00 FF FF FF)
    26 MN 99/01/08 13:28 FP 1 DLC card down
    DLC Failure Kind : Shor t circuit (Station number = 2000)
    Data = (02 00 80 20 00 FF FF FF)
    26 MN 99/01/08 13:28 FP 1 DLC card down
    DLC Failure Kind : Ring wire was grounded (Station number = 2000)
    Data = (03 00 80 20 00 FF FF FF)
    26 MN 99/01/08 13:28 FP 1 DLC card down
    DLC Failure Kind : Tip wire was grounded or terminal was unconnected
    (Station number = 2000)
    Data = (04 00 80 20 00 FF FF FF)
    Table 1-7  Examples of Fault Occurrence Display Using MATWorX (Continued)
    Fault Alarm Date CPU Description 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 29
    26 MN 99/01/08 13:28 FP 1 DLC card down
    DLC Failure Kind : Terminal failure (Station number = 2000)
    Data = (05 00 80 20 00 FF FF FF)
    26 MN 99/01/08 13:28 FP 1 DLC card down
    DLC Failure Kind : Terminal not connected (Station number = 2000)
    Data = (06 00 80 20 00 FF FF FF)
    26 MN 99/01/08 13:28 FP 1 DLC card down
    DLC Failure Kind : Terminal circuit failure (Station number = 2000)
    Data = (08 00 80 20 00 FF FF FF)
    27 MN 99/01/08 13:27 FP 0 Synchronism of DPC missed
    DPC on the side of a partner (DPC Number = 0001FFFF)
    Data = (00 00 01 FF FF FF FF FF)
    27 MN 99/01/08 13:27 FP 0 Synchronism of DPC missed
    DPC on the side of oneself (DPC Number = 0005FFFF)
    Data = (01 00 05 FF FF FF FF FF)
    28 MN 99/01/08 13:28 AP 
    10SMDR output buffer memory overflow
    (Memory Kind = 00 Overflow kind : External relay turns ON and OFF)
    Data = (00 00 FF FF FF FF FF FF)
    2B MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT connection down (CS/ZT No. = 10)
    Data = (00 04 00 10 31 01 FF FF)
    2B MN 99/01/08 13:27 MP CS/ZT fault occurred
    Fault kind : CS/ZT carrier has no space (CS/ZT No. = 10)
    Data = (01 04 00 10 FF FF FF FF)
    Table 1-7  Examples of Fault Occurrence Display Using MATWorX (Continued)
    Fault Alarm Date CPU Description 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 30  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    Table 1-8  Example of Fault Restoration Display Using MATWorX 
    Fault Alarm Date CPU Description
    18 - 99/01/08 13:26 MP FP/AP card returned to normal condition
    (FP/AP NO. = 52)
    Data = (F4 FF FF FF FF FF FF FF)
    19 - 99/01/08 13:26 MP Power failure returned to normal condition
    Recover Kind : AC input failure
    Data = (00 01 02 FF FF FF FF FF)
    19 - 99/01/08 13:26 MP Power failure returned to normal condition
    Recover Kind : fuse break
    Data = (01 02 00 FF FF FF FF FF)
    19 - 99/01/08 13:26 MP Power failure returned to normal condition
    Recover Kind : PWR alarm
    Data = (02 00 01 FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    PCM loss
    Data = (F0 FF FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    Frame  lo ss
    Data = (F1 FF FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    Multi frame loss
    Data = (F2 FF FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    AIS error
    Data = (F3 FF FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    Remote alarm
    Data = (F4 FF FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    Multi Remote alarm
    Data = (F5 FF FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    S-bit error
    Data = (F6 FF FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    CRC error
    Data = (F8 FF FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    Slip detected
    Data = (F9 FF FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    Main signal all 1
    Data = (FA 01 FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    INFO 0
    Data = (FB FF FF FF FF FF FF FF)
    30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition
    INFO 2
    Data = (FC FF FF FF FF FF FF FF) 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 31
    31 - 99/01/08 13:28 AP 6 DCH/BRT/PRT D-channel link connection returned to normal condition
    (D-ch NO. = 3)
    Data = (03 FF FF FF FF FF FF FF)
    32 - 99/01/08 13:28 AP 7 CCH link connection returned to normal condition
    (CCH NO. = 3)
    Data = (03 FF FF FF FF FF FF FF)
    34 - 99/01/08 13:26 FP 0 Number of faulty trunks was less than predetermined number
    Data = (FF FF FF FF FF FF FF FF)
    35 - 99/01/08 13:26 MP Number of lockout stations was less than predetermined number
    Data = (FF FF FF FF FF FF FF FF)
    36 - 99/01/08 13:28 FP1 DLC card returned to normal condition
    Recover Kind No. : 0 (Station number = 200015)
    Data = (00 00 80 20 00 15 FF FF)
    36 - 99/01/08 13:28 FP1 DLC card returned to normal condition
    Recover Kind No. : 2 (Station number = 200016)
    Data = (02 00 80 20 00 16 FF FF)
    36 - 99/01/08 13:28 FP1 DLC card returned to normal condition
    Recover Kind No. : 3 (Station number = 200017)
    Data = (03 00 80 20 00 17 FF FF)
    36 - 99/01/08 13:28 FP1 DLC card returned to normal condition
    Recover Kind No. : 4 (Station number = 200020)
    Data = (04 00 80 20 00 20 FF FF)
    36 - 99/01/08 13:28 FP1 DLC card returned to normal condition
    Recover Kind No. : 5 (Station number = 200021)
    Data = (05 00 80 20 00 21 FF FF)
    36 - 99/01/08 13:28 FP1 DLC card returned to normal condition
    Recover Kind No. : 6 (Station number = 200022)
    Data = (06 00 80 20 00 22 FF FF)
    36 - 99/01/08 13:28 FP1 DLC card returned to normal condition
    Recover Kind No. : 8 (Station number = 200023)
    Data = (08 00 80 20 00 23 FF FF)
    37 - 99/01/08 13:27 FP0 Synchronism of DPC returned to normal condition
    DPC on the side of a partner (DPC Number = 0001FFFF)
    Data = (00 00 01 FF FF FF FF FF)
    37 - 99/01/08 13:27 FP0 Synchronism of DPC returned to normal condition
    DPC on the side of oneself (DPC Number = 0005FFFF)
    Data = (01 00 05 FF FF FF FF FF)
    38 - 99/01/08 13:28 AP 
    10SMDR output buffer memory returned to normal condition
    (Memory Kind = 00)
    Data = (00 FF FF FF FF FF FF FF)
    3B - 99/01/08 13:27 MP CS/ZT returned to normal condition
    Fault kind : CS/ZT connection returned (CS/ZT No. = 10)
    Data = (00 04 00 10 31 01 FF FF)
    3B - 99/01/08 13:27 MP CS/ZT returned to normal condition
    Fault kind : CS/ZT carrier has space (CS/ZT No. = 10)
    Data = (01 04 00 10 FF FF FF FF)
    Table 1-8  Example of Fault Restoration Display Using MATWorX (Continued)
    Fault Alarm Date CPU Description 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 32  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Station Line Status Display
    STATION LINE STATUS DISPLAY
    General Description
    This feature displays the line status for a single line telephone or a Dterm using the CAT or the
    MAT.
    Service Conditions
    (1) This feature is not available when the system is off-line.
    (2) When performing this feature for a single line telephone, this feature may affect the status 
    of the other telephone in the same line circuit card. Therefore, use this feature only when a 
    line fault has occurred (do not use under a normal state).
    Programming Procedure
    No programming is required.
    Operating Procedure
    Operation: 
    Explanation of Screen Information:
    Station Number: X-XXXXXXXX (1-8 digits)
    EC1DE
    +EC1>
    STCOMMAND=
    X-XXXXXXXX
    DE
    +XXXXXXXX : XX XX XX
    (Station No.)XXXXXXXX : XX XX XX
    421
    3
    1 
    						
    All NEC manuals Comments (0)