CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 23 (2) To Clear MJ/MN Alarm To clear both MJ/MN alarms Operation: To clear MJ alarm only Operation: To clear MN alarm only Operation: DE +EA1> EA1 STCOMMAND= DE +EA1>00:00 – 00 EXE +OK CCC DE +EA1> EA1 STCOMMAND= DE +EA1>01:01 – 01 EXE +OK CCC DE +EA1> EA1 STCOMMAND= DE +EA1>02:02 – 02 EXE +OK CCC
NEAX2000 IVS2 Maintenance ManualPage 24 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages (3) To Display Fault Messages using MATWorX Studio Refer to the MATWorX Studio User’s Guide or to the Fault Display online Help in the MATWorX Studio to display fault messages. Table 1-5 provides an explanation of the 8-byte data that appears in the Description column. Table 1-7 shows examples of fault occurrence messages and Ta b l e 1 - 8 shows examples of fault restoration information that the Fault Display add-in may display.
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 25 Table 1-7 Examples of Fault Occurrence Display Using MATWorX Fault Alarm Date CPU Description 01 - 99/01/08 13:26 MP System initialization Type : Power On Initialize Data = (F0 FF FF FF FF FF FF FF) 01 - 99/01/08 13:26 MP System initialization Type : Initialize by Reset Button (SW1) Data = (F1 FF FF FF FF FF FF FF) 01 MJ 99/01/08 13:26 MP System initialization Type : Serious failure 1 Data = (12 23 45 67 89 FF FF FF) 01 MJ 99/01/08 13:26 MP System initialization Type : Serious failure 2 Data = (13 34 56 78 9A FF FF FF) 01 MJ 99/01/08 13:26 MP System initialization Type : Serious failure 3 Data = (F5 FF FF FF FF FF FF FF) 01 MJ 99/01/08 13:26 MP System initialization Type : Serious failure 4 Data = (16 67 89 AB CD FF FF FF) 01 MJ 99/01/08 13:26 MP System initialization Type : Serious failure 5 Data = (F7 FF FF FF FF FF FF FF) 01 MJ 99/01/08 13:26 MP System initialization Type : Serious failure 6 Data = (F8 FF FF FF FF FF FF FF) 01 - 99/01/08 13:26 MP System initialization Type : SW3 Switch was changed to 0 Data = (F9 FF FF FF FF FF FF FF) 01 MJ 99/01/08 13:26 MP System initialization Type : Serious failure 7 Data = (2A 11 22 33 44 FF FF FF) 01 - 99/01/08 13:26 MP System initialization Type : Initialize by CAT or MAT Data = (FB FF FF FF FF FF FF FF) 01 MJ 99/01/08 13:26 MP System initialization Type : switching Data = (FC FF FF FF FF FF FF FF) 03 MN 99/01/08 13:26 MP The number of hopper entry was more than the caution level Hopper kind = H-rank Data = (F0 FF FF FF FF FF FF FF) 03 MN 99/01/08 13:26 MP The number of hopper entry was more than the caution level Hopper kind = L-rank Data = (F1 FF FF FF FF FF FF FF)
NEAX2000 IVS2 Maintenance ManualPage 26 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages 04 MN 99/01/08 13:26 MP MP-FP/AP communication failure Overflow of data sending buffer to FP/AP. (Count = 10 FP/AP NO. = 04) Data = (F0 0A 04 FF FF FF FF FF) 04 MN 99/01/08 13:26 MP MP-FP/AP communication failure Invalid data received from FP/AP. (Count = 96 FP/AP NO. = 07) Data = (F1 60 07 FF FF FF FF FF) 04 MN 99/01/08 13:26 MP MP-FP/AP communication failure Invalid data received from FP/AP. (Count = 100 or more FP/AP NO. = 11) Data = (F1 FF 0B FF FF FF FF FF) 08 MN 99/01/08 13:26 MP FP/AP card down (FP/AP NO. = 52) Data = (F4 FF FF FF FF FF FF FF) 09 MJ 99/01/08 13:26 MP Power failure Power Failure Kind : AC input failure Data = (00 01 02 FF FF FF FF FF) 09 MJ 99/01/08 13:26 MP Power failure Power Failure Kind : Fuse break Data = (01 02 00 FF FF FF FF FF) 09 MJ 99/01/08 13:26 MP Power failure Power Failure Kind : PWR alarm Data = (02 00 01 FF FF FF FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : Fault notice from CS/ZT (CS/ZT No. = 10) Data = (00 04 00 10 31 01 FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT initial failure (CS/ZT No. = 10) Data = (01 04 00 10 31 01 FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT condition read failure (CS/ZT No. = 10) Data = (02 04 00 10 31 01 FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT condition unmatch (CS/ZT No. = 10) Data = (03 04 00 10 31 01 FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : Bch condition unmatch (CS/ZT No. = 10) Data = (04 04 00 10 31 01 FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : SYS-ID upload failure (CS/ZT No. = 10) Data = (05 04 00 10 31 01 FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : SYS-ID download failure (CS/ZT No. = 10) Data = (06 04 00 10 31 01 FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT make busy failure (CS/ZT No. = 10) Data = (07 04 00 10 31 FF FF FF) Table 1-7 Examples of Fault Occurrence Display Using MATWorX (Continued) Fault Alarm Date CPU Description
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 27 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT data load failure (CS/ZT No. = 10) Data = (08 04 00 10 31 FF FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : Bch make busy failure (CS/ZT No. = 10) Data = (09 04 00 10 31 FF FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT operation parameter change failure (CS/ZT No. = 0) Data = (0A FF FF 10 31 FF FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : LCCH sending position failure (CS/ZT No. = 0) Data = (0B FF FF 10 31 FF FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : Carrier selection failure (CS/ZT No. = 0) Data = (0C FF FF 10 31 FF FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT expansion data read failure (CS/ZT No. = 0) Data = (0D 01 FF 10 31 FF FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT expansion data setting failure (CS/ZT No. = 0) Data = (0E FF FF 10 31 FF FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT operation parameter 2 change failure (CS/ZT No. = 0) Data = (0F FF FF 10 31 FF FF FF) 12 MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : (CS/ZT No. = 0) Data = (10 FF FF 10 31 FF FF FF) 16 MN 99/01/08 19:30 MP It is a day for periodic maintenance Battery check (TK = 0) Data = (F8 FF FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure PCM loss Data = (F0 FF FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure Frame lo ss Data = (F1 FF FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure Multi frame loss Data = (F2 FF FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure AIS error Data = (F3 FF FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure Remote alarm Data = (F4 FF FF FF FF FF FF FF) Table 1-7 Examples of Fault Occurrence Display Using MATWorX (Continued) Fault Alarm Date CPU Description
NEAX2000 IVS2 Maintenance ManualPage 28 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages 20 MJ 99/01/08 13:28 AP 5 DTI line failure Multi remote alarm Data = (F5 FF FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure S-bit error Data = (F6 FF FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure CRC error Data = (F8 FF FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure Slip detected Data = (F9 FF FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure Main signal all 1 Data = (FA 01 FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure INFO 0 Data = (FB FF FF FF FF FF FF FF) 20 MJ 99/01/08 13:28 AP 5 DTI line failure INFO 2 Data = (FC FF FF FF FF FF FF FF) 21 MN 99/01/08 13:28 AP 6 DCH/BRT/PRT D-channel link connection failure (D-ch NO. = 3) Data = (03 FF FF FF FF FF FF FF) 22 MN 99/01/08 13:28 AP 7 CCH link connection failure (CCH NO. = 3) Data = (03 FF FF FF FF FF FF FF) 24 MN 99/01/08 13:26 FP 0 Number of faulty trunks was more than predetermined number Data = (FF FF FF FF FF FF FF FF) 25 MN 99/01/08 13:26 MP Number of lockout stations was more than predetermined number Data = (FF FF FF FF FF FF FF FF) 26 MN 99/01/08 13:28 FP 1 DLC card down DLC Failure Kind : Terminal was cut off (Station number = 2000) Data = (00 00 80 20 00 FF FF FF) 26 MN 99/01/08 13:28 FP 1 DLC card down DLC Failure Kind : Shor t circuit (Station number = 2000) Data = (02 00 80 20 00 FF FF FF) 26 MN 99/01/08 13:28 FP 1 DLC card down DLC Failure Kind : Ring wire was grounded (Station number = 2000) Data = (03 00 80 20 00 FF FF FF) 26 MN 99/01/08 13:28 FP 1 DLC card down DLC Failure Kind : Tip wire was grounded or terminal was unconnected (Station number = 2000) Data = (04 00 80 20 00 FF FF FF) Table 1-7 Examples of Fault Occurrence Display Using MATWorX (Continued) Fault Alarm Date CPU Description
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 29 26 MN 99/01/08 13:28 FP 1 DLC card down DLC Failure Kind : Terminal failure (Station number = 2000) Data = (05 00 80 20 00 FF FF FF) 26 MN 99/01/08 13:28 FP 1 DLC card down DLC Failure Kind : Terminal not connected (Station number = 2000) Data = (06 00 80 20 00 FF FF FF) 26 MN 99/01/08 13:28 FP 1 DLC card down DLC Failure Kind : Terminal circuit failure (Station number = 2000) Data = (08 00 80 20 00 FF FF FF) 27 MN 99/01/08 13:27 FP 0 Synchronism of DPC missed DPC on the side of a partner (DPC Number = 0001FFFF) Data = (00 00 01 FF FF FF FF FF) 27 MN 99/01/08 13:27 FP 0 Synchronism of DPC missed DPC on the side of oneself (DPC Number = 0005FFFF) Data = (01 00 05 FF FF FF FF FF) 28 MN 99/01/08 13:28 AP 10SMDR output buffer memory overflow (Memory Kind = 00 Overflow kind : External relay turns ON and OFF) Data = (00 00 FF FF FF FF FF FF) 2B MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT connection down (CS/ZT No. = 10) Data = (00 04 00 10 31 01 FF FF) 2B MN 99/01/08 13:27 MP CS/ZT fault occurred Fault kind : CS/ZT carrier has no space (CS/ZT No. = 10) Data = (01 04 00 10 FF FF FF FF) Table 1-7 Examples of Fault Occurrence Display Using MATWorX (Continued) Fault Alarm Date CPU Description
NEAX2000 IVS2 Maintenance ManualPage 30 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages Table 1-8 Example of Fault Restoration Display Using MATWorX Fault Alarm Date CPU Description 18 - 99/01/08 13:26 MP FP/AP card returned to normal condition (FP/AP NO. = 52) Data = (F4 FF FF FF FF FF FF FF) 19 - 99/01/08 13:26 MP Power failure returned to normal condition Recover Kind : AC input failure Data = (00 01 02 FF FF FF FF FF) 19 - 99/01/08 13:26 MP Power failure returned to normal condition Recover Kind : fuse break Data = (01 02 00 FF FF FF FF FF) 19 - 99/01/08 13:26 MP Power failure returned to normal condition Recover Kind : PWR alarm Data = (02 00 01 FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition PCM loss Data = (F0 FF FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition Frame lo ss Data = (F1 FF FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition Multi frame loss Data = (F2 FF FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition AIS error Data = (F3 FF FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition Remote alarm Data = (F4 FF FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition Multi Remote alarm Data = (F5 FF FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition S-bit error Data = (F6 FF FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition CRC error Data = (F8 FF FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition Slip detected Data = (F9 FF FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition Main signal all 1 Data = (FA 01 FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition INFO 0 Data = (FB FF FF FF FF FF FF FF) 30 - 99/01/08 13:28 AP 5 DTI line returned to normal condition INFO 2 Data = (FC FF FF FF FF FF FF FF)
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 31 31 - 99/01/08 13:28 AP 6 DCH/BRT/PRT D-channel link connection returned to normal condition (D-ch NO. = 3) Data = (03 FF FF FF FF FF FF FF) 32 - 99/01/08 13:28 AP 7 CCH link connection returned to normal condition (CCH NO. = 3) Data = (03 FF FF FF FF FF FF FF) 34 - 99/01/08 13:26 FP 0 Number of faulty trunks was less than predetermined number Data = (FF FF FF FF FF FF FF FF) 35 - 99/01/08 13:26 MP Number of lockout stations was less than predetermined number Data = (FF FF FF FF FF FF FF FF) 36 - 99/01/08 13:28 FP1 DLC card returned to normal condition Recover Kind No. : 0 (Station number = 200015) Data = (00 00 80 20 00 15 FF FF) 36 - 99/01/08 13:28 FP1 DLC card returned to normal condition Recover Kind No. : 2 (Station number = 200016) Data = (02 00 80 20 00 16 FF FF) 36 - 99/01/08 13:28 FP1 DLC card returned to normal condition Recover Kind No. : 3 (Station number = 200017) Data = (03 00 80 20 00 17 FF FF) 36 - 99/01/08 13:28 FP1 DLC card returned to normal condition Recover Kind No. : 4 (Station number = 200020) Data = (04 00 80 20 00 20 FF FF) 36 - 99/01/08 13:28 FP1 DLC card returned to normal condition Recover Kind No. : 5 (Station number = 200021) Data = (05 00 80 20 00 21 FF FF) 36 - 99/01/08 13:28 FP1 DLC card returned to normal condition Recover Kind No. : 6 (Station number = 200022) Data = (06 00 80 20 00 22 FF FF) 36 - 99/01/08 13:28 FP1 DLC card returned to normal condition Recover Kind No. : 8 (Station number = 200023) Data = (08 00 80 20 00 23 FF FF) 37 - 99/01/08 13:27 FP0 Synchronism of DPC returned to normal condition DPC on the side of a partner (DPC Number = 0001FFFF) Data = (00 00 01 FF FF FF FF FF) 37 - 99/01/08 13:27 FP0 Synchronism of DPC returned to normal condition DPC on the side of oneself (DPC Number = 0005FFFF) Data = (01 00 05 FF FF FF FF FF) 38 - 99/01/08 13:28 AP 10SMDR output buffer memory returned to normal condition (Memory Kind = 00) Data = (00 FF FF FF FF FF FF FF) 3B - 99/01/08 13:27 MP CS/ZT returned to normal condition Fault kind : CS/ZT connection returned (CS/ZT No. = 10) Data = (00 04 00 10 31 01 FF FF) 3B - 99/01/08 13:27 MP CS/ZT returned to normal condition Fault kind : CS/ZT carrier has space (CS/ZT No. = 10) Data = (01 04 00 10 FF FF FF FF) Table 1-8 Example of Fault Restoration Display Using MATWorX (Continued) Fault Alarm Date CPU Description
NEAX2000 IVS2 Maintenance ManualPage 32 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Station Line Status Display STATION LINE STATUS DISPLAY General Description This feature displays the line status for a single line telephone or a Dterm using the CAT or the MAT. Service Conditions (1) This feature is not available when the system is off-line. (2) When performing this feature for a single line telephone, this feature may affect the status of the other telephone in the same line circuit card. Therefore, use this feature only when a line fault has occurred (do not use under a normal state). Programming Procedure No programming is required. Operating Procedure Operation: Explanation of Screen Information: Station Number: X-XXXXXXXX (1-8 digits) EC1DE +EC1> STCOMMAND= X-XXXXXXXX DE +XXXXXXXX : XX XX XX (Station No.)XXXXXXXX : XX XX XX 421 3 1