    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 13
    Table 1-2  Fault Restoration Kind Number
    FAULT KIND NUMBER FAULT RESTORATION CONTENT
    18 FP/AP card returned to normal condition
    19 Power failure returned to normal condition
    30 DTI line returned to normal condition
    31 DCH/BRT/PRT D-channel link connection returned to normal
    condition
    32 CCH link connection returned to normal condition
    34
    [Australia Only]Number of faulty trunks was less than predetermined number
    35 Number of lockout stations was less than predetermined number
    36 DLC card returned to normal condition
    37 Synchronism of DPC returned to normal condition
    38 SMDR output buffer memory returned to normal condition
    3B CS/ZT returned to normal condition 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 14  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    : External Alarm Kind (MJ/MN/–)
    External Alarm Kind—Minor (MN), Major (MJ), or no alarm (external alarm not provided) is 
    programmed by CMEA Y=2. Table 1-3 shows the standard data set by the 2nd data=3 of 
    CMEA Y=2.
    Table 1-3  Standard Data Set of External Alarm Kind 
    FAU LT  
    KINDFAULT CONTENTALARM 
    KIND
    01 System Initialization MN ALARM
    04 MP-FP/AP communication failure MN ALARM
    08 FP/AP card down MN ALARM
    09 Power failure MJ ALARM
    12 CS/ZT fault occurred–
    16 It is a day for periodic maintenance–
    18 FP/AP card returned to normal condition–
    19 Power failure returned to normal condition–
    20 DTI line failure MN ALARM
    21 DCH/BRT/PRT D-channel link connection failure MN ALARM
    22 CCH link connection failure MN ALARM
    24
    [Australia 
    Only]Number of faulty trunks was more than predetermined number MJ/MN 
    ALARM
    25 Number of lockout stations was more than predetermined
    number (Refer to CM42>01 in Command Manual.)MN ALARM
    (Fixed)
    26 DLC card down–
    27 Synchronism of DPC missed MN ALARM
    28 SMDR output buffer memory overflow MN ALARM
    2B CS/ZT fault occurred–
    30 DTI line returned to normal condition–
    31 DCH/BRT/PRT D-channel link connection returned to normal
    condition–
    32 CCH link connection returned to normal condition–
    2 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 15
    The alarm lamps in Ta b l e  1 - 4 are indicated according to the alarm kind. 34
    [Australia 
    Only]Number of faulty trunks was less than predetermined number–
    35 Number of lockout stations was less than predetermined 
    number–
    36 DLC card returned to normal condition–
    37 Synchronism of DPC returned to normal–
    38 SMDR output buffer memory returned to normal condition–
    3B CS/ZT returned to normal condition–
    Table 1-4  Alarm Kind and Alarm Lamps
    Alarm Lamp
    Alarm KindExternal Alarm 
    Indication 
    MJExternal Alarm 
    Indication 
    MNPZ-PW121
    MJPZ-PW121
    MN
    MJ Steady light–Steady light–
    MN–Steady light–Steady light
    Table 1-3  Standard Data Set of External Alarm Kind (Continued)
    FAU LT  
    KINDFAULT CONTENTALARM 
    KIND 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 16  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    - : Fault Information/Fault Restoration Information
    Table 1-5  Fault Information
    FAU LT  
    KIND 
    NUMBER
    01 Initial Kind,
    ,System Initialization Information
    04 Communication 
    Failure KindNumber of 
    Communication 
    FailuresFP/AP No.
    08
    FP/AP No. 
    09 Power Failure 
    Kind 1 Power Failure 
    Kind 2 Power Failure 
    Kind 3 
    12
    Fault Kind  AP No. CS/ZT Interface No. 
    16 Inspection Kind 
    20 Fault Detail Kind 
    21
    D-ch No. 
    22
    CCH No. 
    24
    25
    26 DLC Failure 
    Kind LEN Station No. 
    27 DPC Failure
    Kind DPC No. 
    28 Memory Kind Overflow Kind 
    2B
    Fault Kind  AP No. CS/ZT Interface No. 
    512
    56789101112
    abc
    d
    e
    e
    fff
    gh
    i
    j
    l
    m
    n
    o
    p
    q
    r
    s
    tu
    vw
    x 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 17
    Table 1-6  Fault Restoration Information
    FAU LT  
    KIND 
    NUMBER
    18 FP/AP
    No. 
    19 Power Failure 
    Kind 1 Power Failure 
    Kind 2 Power Failure 
    Kind 3 
    30 Fault Detail 
    Kind 
    31
    D-ch No. 
    32
    CCH No. 
    34
    35
    36 DLC Failure 
    Kind LEN 
    Station No. 
    37 DPC Failure
    Kind DPC No. 
    38 Memory
    Kind 
    3B
    Fault Kind  AP No.  CS/ZT Interface No. 
    56789101112
    e
    kkk
    l
    m
    n
    o
    pq
    r
    s
    t
    yzA 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 18  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    : Kind of System Initialization information (Upper digit)
    1: Program address information
    2: Receive command information
    F: No system initialization information
    : Initial Kind (Lower digit)
    0: Power On Initialize
    1: Initialize by Reset Button (SW1)
    2: Serious failure 1
    3: Serious failure 2
    4: Not used
    5: Serious failure 3
    6: Serious failure 4
    7: Serious failure 5
    8: Serious failure 6
    9: SW3 was changed to 0
    A: Serious failure 7
    B: Initialize by CAT/MAT
    C: Not used
    D: Not used
    E: Not used
    F: Not used
    : System Initialization Information
    The address of the program which caused system initialization
    : Communication Failure Kind
    00: Overflow of data sending buffer to the FP/AP
    01: Invalid data received from FP/AP
    : FP/AP Number
    00-03 : FP No. 0-3
    04-15, 20-31 : AP No. 4-15, 20-31a
    b
    c
    d
    e 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 19
    : Power Failure Kind
    00: AC input failure
    01: Fuse break
    02: PWR alarm
    :Fault Kind
    00: Fault notice from CS/ZT
    01: CS/ZT initial failure
    02: CS/ZT condition read failure
    03: CS/ZT condition unmatch
    04: B channel condition unmatch
    05: SYS-ID upload failure
    06: SYS-ID download failure
    07: CS/ZT make busy failure
    08: CS/ZT data load failure
    09: B channel make busy failure
    0A: CS/ZT operation parameter change failure
    0B: LCCH sending position failure
    0C: Carrier selection failure [North America/Latin America Only]
    0D: CS/ZT expansion data read failure
    0E: CS/ZT expansion data setting failure
    0F: CS/ZT operation parameter 2 change failure
    : AP No. of CS/ZT fault occurred 04-15, 20-31
    : CS/ZT Interface No. of fault occurred 000-255
    : Inspection Kind
    00: Battery check
    : Power Failure Restoration Kind
    00: AC input failure
    01: Fuse break
    02: PWR alarmf
    g
    h
    i
    j
    k 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 20  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    : Fault Detail Kind
    00: PCM loss
    01: Frame loss
    02: Multi frame loss
    03: AIS error
    04: Remote alarm
    05: Multi remote alarm
    06: S-bit error
    07: Not used
    08: CRC error
    09: Slip detected
    0A: Main signal all 1 (for BRT)
    0B: INFO 0 (for BRT)
    0C: INFO 2 (for BRT)
    0D: Not used
    0E: Not used
    0F: Not used
    : D-channel Circuit No.
    DCH/BRT/PRT: 00-07 =D-channel No. 0-7
    : CCH No.
    00-07=CCH No. 0-7
    : DLC Failure Kind
    00:Terminal was cut off
    02: Shor t circuit 
    03: Ring wire was grounded
    04: Tip wire was grounded or terminal was unconnected
    05: Terminal failure
    08: Terminal circuit failure
    : LEN (000-763)
    : Station No. (X-XXXXXXXX)l
    m
    n
    o
    p
    q 
    						
    							CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    NEAX2000 IVS2 Maintenance Manual    
    ND-70926 (E), Issue 1.0   Page 21
    : DPC Failure Kind
    00: DPC on the side of par tner
    01: DPC on the side of oneself
    :DPC No.
    : Memory Kind
    00: Billing memory block
    01: Host CPU No. 0 output Buffer memory block
    02: Host CPU No. 1 output Buffer memory block
    03: Automatic print Buffer memory block
    04: Notice of the rest of memory block numbers in the system
    05: CCIS output Buffer memory block
    06: CS report traffic data memory block
    : Overflow Kind
    When setting CMD000>126:0
    00: Memory accumulation exceeds the value set by CMD001>229 or CMD003>26-30
    01: Memory overflowed
    When setting CMD000>126:1
    01: Memory accumulation exceeds the value set by CMD001>229 or CMD003>26-30
    For memory kind 04, regardless of CMD000>126
    01: Memory accumulation exceeds the value set by CMD001>229 or CMD003>26-30
    :Fault Kind
    00: CS/ZT connection down
    01: CS/ZT carrier has no space
    : AP No. of CS/ZT fault occurred 04-15, 20-31
    : CS/ZT Interface No. of CS/ZT fault occurred 000-255r
    s
    t
    u
    v
    w
    x 
    						
    							 NEAX2000 IVS2 Maintenance ManualPage 22  ND-70926 (E), Issue 1.0
    CHAPTER 1  MAINTENANCE SERVICE FEATURES
    Fault Messages
    : Fault Restoration Kind
    00: CS/ZT connection returned
    01: CS/ZT carrier has space
    : AP No. returned to normal condition
    : CS/ZT Interface No. returned to normal conditiony
    z
    A 
    						