NEC Neax 2000 Ivs2 Maintenance Manual
Have a look at the manual NEC Neax 2000 Ivs2 Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 13 Table 1-2 Fault Restoration Kind Number FAULT KIND NUMBER FAULT RESTORATION CONTENT 18 FP/AP card returned to normal condition 19 Power failure returned to normal condition 30 DTI line returned to normal condition 31 DCH/BRT/PRT D-channel link connection returned to normal condition 32 CCH link connection returned to normal condition 34 [Australia Only]Number of faulty trunks was less than predetermined number 35 Number of lockout stations was less than predetermined number 36 DLC card returned to normal condition 37 Synchronism of DPC returned to normal condition 38 SMDR output buffer memory returned to normal condition 3B CS/ZT returned to normal condition
NEAX2000 IVS2 Maintenance ManualPage 14 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages : External Alarm Kind (MJ/MN/–) External Alarm Kind—Minor (MN), Major (MJ), or no alarm (external alarm not provided) is programmed by CMEA Y=2. Table 1-3 shows the standard data set by the 2nd data=3 of CMEA Y=2. Table 1-3 Standard Data Set of External Alarm Kind FAU LT KINDFAULT CONTENTALARM KIND 01 System Initialization MN ALARM 04 MP-FP/AP communication failure MN ALARM 08 FP/AP card down MN ALARM 09 Power failure MJ ALARM 12 CS/ZT fault occurred– 16 It is a day for periodic maintenance– 18 FP/AP card returned to normal condition– 19 Power failure returned to normal condition– 20 DTI line failure MN ALARM 21 DCH/BRT/PRT D-channel link connection failure MN ALARM 22 CCH link connection failure MN ALARM 24 [Australia Only]Number of faulty trunks was more than predetermined number MJ/MN ALARM 25 Number of lockout stations was more than predetermined number (Refer to CM42>01 in Command Manual.)MN ALARM (Fixed) 26 DLC card down– 27 Synchronism of DPC missed MN ALARM 28 SMDR output buffer memory overflow MN ALARM 2B CS/ZT fault occurred– 30 DTI line returned to normal condition– 31 DCH/BRT/PRT D-channel link connection returned to normal condition– 32 CCH link connection returned to normal condition– 2
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 15 The alarm lamps in Ta b l e 1 - 4 are indicated according to the alarm kind. 34 [Australia Only]Number of faulty trunks was less than predetermined number– 35 Number of lockout stations was less than predetermined number– 36 DLC card returned to normal condition– 37 Synchronism of DPC returned to normal– 38 SMDR output buffer memory returned to normal condition– 3B CS/ZT returned to normal condition– Table 1-4 Alarm Kind and Alarm Lamps Alarm Lamp Alarm KindExternal Alarm Indication MJExternal Alarm Indication MNPZ-PW121 MJPZ-PW121 MN MJ Steady light–Steady light– MN–Steady light–Steady light Table 1-3 Standard Data Set of External Alarm Kind (Continued) FAU LT KINDFAULT CONTENTALARM KIND
NEAX2000 IVS2 Maintenance ManualPage 16 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages - : Fault Information/Fault Restoration Information Table 1-5 Fault Information FAU LT KIND NUMBER 01 Initial Kind, ,System Initialization Information 04 Communication Failure KindNumber of Communication FailuresFP/AP No. 08 FP/AP No. 09 Power Failure Kind 1 Power Failure Kind 2 Power Failure Kind 3 12 Fault Kind AP No. CS/ZT Interface No. 16 Inspection Kind 20 Fault Detail Kind 21 D-ch No. 22 CCH No. 24 25 26 DLC Failure Kind LEN Station No. 27 DPC Failure Kind DPC No. 28 Memory Kind Overflow Kind 2B Fault Kind AP No. CS/ZT Interface No. 512 56789101112 abc d e e fff gh i j l m n o p q r s tu vw x
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 17 Table 1-6 Fault Restoration Information FAU LT KIND NUMBER 18 FP/AP No. 19 Power Failure Kind 1 Power Failure Kind 2 Power Failure Kind 3 30 Fault Detail Kind 31 D-ch No. 32 CCH No. 34 35 36 DLC Failure Kind LEN Station No. 37 DPC Failure Kind DPC No. 38 Memory Kind 3B Fault Kind AP No. CS/ZT Interface No. 56789101112 e kkk l m n o pq r s t yzA
NEAX2000 IVS2 Maintenance ManualPage 18 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages : Kind of System Initialization information (Upper digit) 1: Program address information 2: Receive command information F: No system initialization information : Initial Kind (Lower digit) 0: Power On Initialize 1: Initialize by Reset Button (SW1) 2: Serious failure 1 3: Serious failure 2 4: Not used 5: Serious failure 3 6: Serious failure 4 7: Serious failure 5 8: Serious failure 6 9: SW3 was changed to 0 A: Serious failure 7 B: Initialize by CAT/MAT C: Not used D: Not used E: Not used F: Not used : System Initialization Information The address of the program which caused system initialization : Communication Failure Kind 00: Overflow of data sending buffer to the FP/AP 01: Invalid data received from FP/AP : FP/AP Number 00-03 : FP No. 0-3 04-15, 20-31 : AP No. 4-15, 20-31a b c d e
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 19 : Power Failure Kind 00: AC input failure 01: Fuse break 02: PWR alarm :Fault Kind 00: Fault notice from CS/ZT 01: CS/ZT initial failure 02: CS/ZT condition read failure 03: CS/ZT condition unmatch 04: B channel condition unmatch 05: SYS-ID upload failure 06: SYS-ID download failure 07: CS/ZT make busy failure 08: CS/ZT data load failure 09: B channel make busy failure 0A: CS/ZT operation parameter change failure 0B: LCCH sending position failure 0C: Carrier selection failure [North America/Latin America Only] 0D: CS/ZT expansion data read failure 0E: CS/ZT expansion data setting failure 0F: CS/ZT operation parameter 2 change failure : AP No. of CS/ZT fault occurred 04-15, 20-31 : CS/ZT Interface No. of fault occurred 000-255 : Inspection Kind 00: Battery check : Power Failure Restoration Kind 00: AC input failure 01: Fuse break 02: PWR alarmf g h i j k
NEAX2000 IVS2 Maintenance ManualPage 20 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages : Fault Detail Kind 00: PCM loss 01: Frame loss 02: Multi frame loss 03: AIS error 04: Remote alarm 05: Multi remote alarm 06: S-bit error 07: Not used 08: CRC error 09: Slip detected 0A: Main signal all 1 (for BRT) 0B: INFO 0 (for BRT) 0C: INFO 2 (for BRT) 0D: Not used 0E: Not used 0F: Not used : D-channel Circuit No. DCH/BRT/PRT: 00-07 =D-channel No. 0-7 : CCH No. 00-07=CCH No. 0-7 : DLC Failure Kind 00:Terminal was cut off 02: Shor t circuit 03: Ring wire was grounded 04: Tip wire was grounded or terminal was unconnected 05: Terminal failure 08: Terminal circuit failure : LEN (000-763) : Station No. (X-XXXXXXXX)l m n o p q
CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages NEAX2000 IVS2 Maintenance Manual ND-70926 (E), Issue 1.0 Page 21 : DPC Failure Kind 00: DPC on the side of par tner 01: DPC on the side of oneself :DPC No. : Memory Kind 00: Billing memory block 01: Host CPU No. 0 output Buffer memory block 02: Host CPU No. 1 output Buffer memory block 03: Automatic print Buffer memory block 04: Notice of the rest of memory block numbers in the system 05: CCIS output Buffer memory block 06: CS report traffic data memory block : Overflow Kind When setting CMD000>126:0 00: Memory accumulation exceeds the value set by CMD001>229 or CMD003>26-30 01: Memory overflowed When setting CMD000>126:1 01: Memory accumulation exceeds the value set by CMD001>229 or CMD003>26-30 For memory kind 04, regardless of CMD000>126 01: Memory accumulation exceeds the value set by CMD001>229 or CMD003>26-30 :Fault Kind 00: CS/ZT connection down 01: CS/ZT carrier has no space : AP No. of CS/ZT fault occurred 04-15, 20-31 : CS/ZT Interface No. of CS/ZT fault occurred 000-255r s t u v w x
NEAX2000 IVS2 Maintenance ManualPage 22 ND-70926 (E), Issue 1.0 CHAPTER 1 MAINTENANCE SERVICE FEATURES Fault Messages : Fault Restoration Kind 00: CS/ZT connection returned 01: CS/ZT carrier has space : AP No. returned to normal condition : CS/ZT Interface No. returned to normal conditiony z A