NEC Neax 2000 Ivs2 Ccis Features And Specifications
Have a look at the manual NEC Neax 2000 Ivs2 Ccis Features And Specifications online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CALLING NUMBER DISPLAY - CCIS NEAX2000 IVS2 CCIS Features and Specifications NDA-24272, Issue 1.0 Page 41 Figure 12 Inter-Office Connections for Intermediate Station Number Display (1) 8202000 NEAX2000 IVS2/2400 Elapsed time Calling station CALLED CALLINGCCIS820822 NEAX2000 IVS 2 B: 4211 Called party (C)NEAX2000 IVS2 821 PARTY ANSWERS Type of trunk (Time Display) Calling party number flashes A: 2000 A: Dial 822-4211 C: 5000 B: Intermediate station B C Call forwarding all calls 8224211 Calling party (A) (Time Display) Dialed number Type of forwarding Intermediate station number (B) 8225000 (Time Display) 8202000 (Time Display) numberElapsed time Called station number
CALLING NUMBER DISPLAY - CCIS NEAX2000 IVS2 CCIS Features and SpecificationsPage 42 NDA-24272, Issue 1.0 Figure 13 Inter-Office Connections for Intermediate Station Number Display (2) 8202000 NEAX2000 IVS2/2400 Elapsed time Calling station CALLED CALLINGCCIS820822 B: 4211 Called party (C) 821 PARTY ANSWERS (Time Display) Calling party number flashes A: 2000 A: Dial 822-4211 C: 5000 B: Intermediate station B C Call forwarding all calls 4211 Calling party (A) (Time Display) Dialed number 8225000 (Time Display) 8202000 (Time Display) numberElapsed time Called station number
CENTRALIZED BILLING - CCIS NEAX2000 IVS2 CCIS Features and Specifications NDA-24272, Issue 1.0 Page 43 CENTRALIZED BILLING - CCIS General Description This feature is used to collect billing information from each office within the network and to direct it to the associated center office. Billing information is then forwarded to the central billing centers via RS-232C interfaces. Operating Procedure No manual operation is required. The call record outputs are produced automatically. Service Conditions 1. The NEAX2000 IVS2 is generally used as a local office, however, it can be used as a center office for centralized billing if all the PBXs within the network are NEAX2000 IVS2. 2. The information storage capacity of the local office is approximately 1,000 calls. 3. If billing information in excess of the above mentioned storage capacity is required for a local office, then the addition of a memory card with SRAM card allows 12,000 records of storage per system. 4. When the NEAX2000 IVS 2 is used as a center office, the billing information is sent to a SMDR system with NEAX2400 IMX format. 5. When the NEAX2000 IVS 2 is used as a center office, a maximum number of call records which can be sent to the SMDR system is about 4000 per hour at 4800 bps on the RS-232C port. When the AP of the center office can not send the call records to the SMDR, due to such as a failure of the SMDR system, call records are stored in the memory buffer on the AP (about 500 call records). Moreover, if the memory buffer is filled, the call records are stored in an AP of a local office. 6. When a NEAX2400 is used as a center office, either the Sub Line or the My Line number can be selected by system programming to be sent to the SMDR terminal. 7. When the NEAX2000 IVS 2 is used as a center office, only the My Line number can be sent to the SMDR terminal.
CENTRALIZED BILLING - CCIS NEAX2000 IVS2 CCIS Features and SpecificationsPage 44 NDA-24272, Issue 1.0 8. Billing messages are made in each gateway to the public network. CCIS Link CCIS Link CCIS Link NEAX2000 IVS 2 NEAX2000 IVS2 NEAX2000 IVS2 LOCALLOCALBILLING MSG BILLING LOCAL BILLING MSGRS-232C CENTER OFFICE BILLING MSG CENTRALIZED MSGBILLING CENTER NEAX2400/ OFFICE OFFICE OFFICENEAX2000 IVS 2
CENTRALIZED BILLING - CCIS NEAX2000 IVS2 CCIS Features and Specifications NDA-24272, Issue 1.0 Page 45 9. Billing messages at each location can be sent to Billing Center 1 or Billing Center 2. Example: Location A B Billing Center 2 Location B Billing Center 2 Location C D Billing Center 1 Location D Billing Center 1 NEAX2000 IVS2 NEAX2000 IVS2 NEAX2000 IVS2 LOCALLOCAL BILLING MSG BILLING LOCAL BILLING MSGRS-232C CENTER OFFICE BILLING MSG CENTRALIZED MSGBILLING CENTER 1 NEAX2400/ OFFICE OFFICE OFFICE CENTRALIZED BILLING CENTER 2 AB C D NEAX2000 IVS 2
CENTRALIZED BILLING - CCIS NEAX2000 IVS2 CCIS Features and SpecificationsPage 46 NDA-24272, Issue 1.0 10. When a call is originated from a station (Station A) of a local office (without AP00), via a COT of a center office (with AP00), a message is sent to the center office from the local office via CCIS. According to the station number of the calling party the AP00 of the center office generates billing information to the SMDR terminal. 11. When a call is originated from a Sub Line on the Multiline Terminal station (Station A) of the local office, either the Sub Line or the Primary Extension number can be selected by system programming to be sent to the SMDR terminal. 12. When a call is originated from a station (Station B) of the center office, only the Primary Extension number can be sent to the SMDR terminal. 13. By predetermined office data, Local Office Number of the calling station can be forwarded to the center office, and output to the SMDR terminal. AP00SMDR Terminal Center Office COT Station B Station A without AP00 L ocal Office CCIS Billing Message
CENTRALIZED DAY/NIGHT MODE CHANGE - CCIS NEAX2000 IVS2 CCIS Features and Specifications NDA-24272, Issue 1.0 Page 47 CENTRALIZED DAY/NIGHT MODE CHANGE - CCIS General Description This feature switches the Day/Night mode of a remote office, linked to the main office NEAX2400 IMX via CCIS, in accordance with the Day/Night mode switching on the Attendant Console at the main office. Operating Procedure Main Office: 1. The Attendant executes Day/Night mode changeover operation using the normal Attendant Consoles (no master) method or the master Attendant Console method. 2. After a specified time, the Day/Night mode at the remote office is changed over. Remote Office: 1. No operation is required. Service Conditions 1. The NEAX2000 IVS2 can only be used as a remote office. 2. At a remote office, only one Tenant (Tenant number 01) can use this feature. 3. When a remote office is equipped with an Attendant Console, a changeover of the remote office’s Day/ Night mode should not be performed from the Attendant Console of the remote office. 4. An indication on external equipment at a remote office can be provided when Day/Night mode status is changed by the Attendant Console of the main office. The external equipment is to be provided by the customer and to be connected with a PN-DK00 card. The indication is as follows: Status Indication NIGHT mode ON DAY mode OFF
CONSULTATION HOLD - ALL CALLS - CCIS NEAX2000 IVS2 CCIS Features and SpecificationsPage 48 NDA-24272, Issue 1.0 CONSULTATION HOLD - ALL CALLS - CCIS General Description This feature permits a station user, within the CCIS network, to hold any incoming or outgoing public network or Tie Line call while originating a call to another station within the CCIS network. Operating Procedure To hold the original call and place a second call from a Single Line Telephone: 1. Press the hookswitch momentarily and receive Feature Dial Tone. 2. The original call is placed on hold and receives Music On Hold, if provided. 3. Dial the second station number and receive ringback tone. 4. The second station answers. The original call is now on Consultation Hold - All Calls - CCIS. To return to the original call from a Single Line Telephone: 1. In any of the following cases, the calling station can return to the original call by momentarily pressing the hookswitch: a. The second station called is busy. b. The calling station cannot gain access to the second station due to restriction. c. The second station does not answer. 2. If the second party hangs up, the calling station will automatically be returned to the original call. 3. If the originating station momentarily presses the hookswitch, a three-party Conference will be initiated. To hold the original call and place a second call from a Multiline Terminal: 1. Press the Transfer key and receive Feature Dial Tone. 2. The original call is placed on hold and receives Music On Hold, if provided. 3. Dial the second station number and receive ringback tone. 4. The second station answers. The original call is now on Consultation Hold - All Calls - CCIS.
CONSULTATION HOLD - ALL CALLS - CCIS NEAX2000 IVS2 CCIS Features and Specifications NDA-24272, Issue 1.0 Page 49 To return to the original call from a Multiline Terminal: 1. In any of the following cases, the calling station can return to the original call by pressing the Transfer key: a. The second station called is busy. b. The calling station cannot gain access to the second station due to a restriction. c. The second station does not answer. 2. If the second station hangs up, the calling station will automatically be returned to the original call. 3. If the second station remains in the conversation, pressing the Trasfer or Answer key returns the original call to the Multiline Terminal while the second call enters Consultation Hold -All Calls - CCIS. 4. By pressing the Conf key, a three-party conference will be initiated. Service Conditions When Trunk-To-Trunk Connection is provided, an outgoing exchange network or Tie Line call can be made by the station user.
DELUXE TRAVELING CLASS MARK - CCIS NEAX2000 IVS2 CCIS Features and SpecificationsPage 50 NDA-24272, Issue 1.0 DELUXE TRAVELING CLASS MARK - CCIS General Description This feature provides outgoing call restrictions within the CCIS network. The following three types of restrictions are allowed: Deluxe Traveling Class Mark Restriction Route Restriction Numbering Restriction Operating Procedure No manual operation is required. Service Conditions 1. The Route Restriction Class (RSC) of the calling party is sent to the called office as a Deluxe Traveling Class Mark (TCM), which is used for call restriction. 2. A maximum of eight restriction levels can be sent as a TCM. 3. The Transmitted Restriction Class (TRC) is used to check restrictions on calls outside the CCIS network, from a different switch. 4. The Route Restriction method is used to restrict a call based on the caller’s restriction class and the selected route. 5. Numbering Toll Restriction is used to restrict a call based on the number dialed. 6. The following additional restriction features can be used by an office within the CCIS network: Time of Day Change Day of Week Change