    							CHAPTER 3 ND-45492 (E)
    Pag e 3 4
    Revision 2.0
    (9) Confirm the connection of the PWR CNT CA-A and power output cables as shown in Figure 003-10
    (These cables are pre-installed).
    Figure 003-10  Cable Connection between the PZ-PW86 and the BWB
    NAP 200-003
    Sheet 12/37
    Installation of Main Equipment
    LTC CONNECTOR AREA
    PIM
    BWB (Back Wiring Board)PZ-PW86
    PWR0B PWR0A
    RS
    PWR1
    PWR CNT CA-A
    POWER OUTPUT CABLE (CR,E)
    POWER OUTPUT CABLE (+5V, -27V, E)CARD SLOT AREA 
    						
    							ND-45492 (E) CHAPTER 3
    Page 35
    Revision 2.0
    (10) AC CORD-B and AC Power Cable Wiring
    (a) The AC CORD-B and the AC Power Cable Wiring to the FG, NEUTRAL and LINE terminals inside
    the BASE are shown in Figure 003-11 (for details of wiring to the terminals, see Figure 003-12).
    Figure 003-11  AC CORD-B and AC Power Cable Wiring
    NAP 200-003
    Sheet 13/37
    Installation of Main Equipment
    TO      GROUND TERMINAL
    FRONTSEE FIGURE 003-12AC CORD-B
    3P AC POWER CABLE
    PIM
    PIM
    BASE 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 3 6
    Revision 2.0
    (b) Secure the AC CORD-B cables to the FG, NEUTRAL and LINE terminals as shown in Figure 003-
    12.  The 3P AC Power Cable and the FG Cable are pre-installed with the BASE.
    Figure 003-12  Screwing the AC CORD-B to the Terminals
    NAP 200-003
    Sheet 14/37
    Installation of Main Equipment
    FG
    NEUTRAL
    LINE
    BASE
    3P AC POWER CABLE
    TO 120/240 V AC  
    SOURCE POWER
    AC POWER 
    KNOCK OUT HOLE
    (PROVIDED WITH BASE)
    FG CABLE
    (PROVIDED WITH BASE)
    PIMAC CORD-B 
    TO PZ-PW86 IN PIM 
    (PROVIDED WITH PIM)
    PUSH 
    PULL:  INSERT THE AC CORD 
    :  FIXED THE AC CORD
    CORD BUSH 
    (PROVIDED WITH BASE)
    SUPPLEMENTARY GROUND
    (TO COLD WATER PIPE, ETC.) 
    						
    							ND-45492 (E) CHAPTER 3
    Page 37
    Revision 2.0
    (c) When the system is a two-frame configuration, the 3P AC Power Cable of the left side frame can go
    through the BASE of the right side frame, as shown in Figure 003-12.
    Figure 003-13  AC Power Cable Wiring for Two-Frame Configuration
    NAP 200-003
    Sheet 15/37
    Installation of Main Equipment
    FGNEUTRALLINEFGNEUTRALLINE
    3P AC POWER CABLE
    TO 120/240 V AC 
    SOURCE POWER
    SUPPLEMENTARY GROUND
    (TO COLD WATER PIPE, ETC.) 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 3 8
    Revision 2.0
    (11) When the system is a multiple-PIM configuration, connect the PZ-PW86 Cards to each other using PWR
    CA-A cables, as shown in Figure 003-14 and Figure 003-15.
    Figure 003-14  PWR CA-A
    NAP 200-003
    Sheet 16/37
    Installation of Main Equipment
    550mm (21.7 inch)
    PWR CA-A 
    						
    							ND-45492 (E) CHAPTER 3
    Page 39
    Revision 2.0
    (a) When using an External Battery or the BATTM
    Figure 003-15  Connection of PWR CA-A Cables (1 of 2)
    NAP 200-003
    Sheet 17/37
    Installation of Main Equipment
    PIM7
    PIM6
    PIM5
    PIM4 PIM3
    PIM2
    PIM1
    PIM0PWR CA-APZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1
    TO BATTERYPZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1
    TO BATTERY PWR CA-A
    Note:For details of battery connection, see NAP- 200-005.
    PWR CA-A
    PWR CA-A
    PWR CA-A
    PWR CA-A 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 4 0
    Revision 2.0
    (b) When using an Internal Battery
    Figure 003-15  Connection of PWR CA-A Cables (2 of 2)
    NAP 200-003
    Sheet 18/37
    Installation of Main Equipment
    PIM7
    PIM6
    PIM5
    PIM4 PIM3
    PIM2
    PIM1
    PIM0PZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1PZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1
    PZ-PW86
    BATT2
    BATT1 TO BATTERY
    PWR CA-A
    TO BATTERY
    TO BATTERY
    PWR CA-A
    TO BATTERY TO BATTERY
    PWR CA-A
    TO BATTERY
    TO BATTERY
    PWR CA-A
    TO BATTERY
    Note:For details of battery connection, see NAP- 200-005. 
    						
    							ND-45492 (E) CHAPTER 3
    Page 41
    Revision 2.0
    (12) When the system is a multiple-PIM configuration, mount the PN-BS00 Card in the BUS slot of PIM0. 
    Also, mount the  PN-BS01 Card in each BUS slot of PIM1 through PIM7.
    When the system is a single PIM configuration, neither PN-BS00 nor PN-BS01 is needed.
    Figure 003-16  Mounting of the BUS Cards
    NAP 200-003
    Sheet 19/37
    Installation of Main Equipment
    B
    S
    0
    1
    B
    S
    0
    1
    B
    S
    0
    1
    B
    S
    0
    0
    B
    S
    0
    1
    B
    S
    0
    1
    B
    S
    0
    1
    B
    S
    0
    1
    PIM3
    PIM2
    PIM1
    PIM0PIM7
    PIM6
    PIM5
    PIM4
    BUS SLOT 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 4 2
    Revision 2.0
    (13) When the system is a multiple-PIM configuration, connect all the BUS Cards (PN-BS00/PN-BS01) to each
    other using BUS cables, as shown in Figure 003-17 and Figure 003-18.
    Figure 003-17  BUS Cable
    NAP 200-003
    Sheet 20/37
    Installation of Main Equipment
    700mm (27.6 inch)
    48-TW-0.7 CONN CA 
    						
    							ND-45492 (E) CHAPTER 3
    Page 43
    Revision 2.0
    Figure 003-18  Connection of the BUS Cables
    NAP 200-003
    Sheet 21/37
    Installation of Main Equipment
    PIM7
    PIM6
    PIM5
    PIM4 PIM3
    PIM2
    PIM1
    PIM0BS01
    CN2
    CN1
    CN2
    CN1
    CN2
    CN1
    CN2
    CN1BS01
    CN2
    CN1
    CN2
    CN1
    CN2
    CN1
    CN2
    CN1
    48-TW-0.7 CONN CA
    BS01
    BS01
    BS00BS01
    BS01
    BS01 
    						
    All NEC manuals Comments (0)