    							CHAPTER 3 ND-45492 (E)
    Pag e 1 24
    Revision 2.0
    (11) External Tone Source Equipment
    The cross connection for a customer owned external tone source equipment is shown in Figure 007-32
    through Figure 007-34  as an example.
    Requirement for the External Tone Source Equipment
    • Output level : Less than 0 dBm (Adjustable)
    • Output impedance : Less than 1 kW (When using PN-4COT and PN-DK00)
    : Less than 10 kW (When using Pin Jacks on PN-TNTA)
    • Control Method : Start - Ground Start 
     Note 1
    : Stop - Ground Off (Open)
    Note 1:The current capacity of relay driver (PN-DK00 card) is 0.125 A.
    Note 2:When connecting the external tone source equipment using the PN-4COT and PN-DK00 cards, an appro-
    priate diode must be installed on the MDF, as shown in Figure 007-32.
    NAP 200-007
    Sheet 39/56
    Termination of Cables on the MDF 
    						
    							ND-45492 (E) CHAPTER 3
    Page 125
    Revision 2.0
    (a) Outline of the Connection
    Figure 007-32  Outline of the External Tone Source Connection
    NAP 200-007
    Sheet 40/56
    Termination of Cables on the MDF
    • When using PN-4COT and PN-DK00
    • When using Pin Jacks on PN-TNTA
    • When using Pin Jack on PN-CP03
    PBX
    PN-DK00 Card
    MDF
    Diode*
    External Tone Source Equipment
    PBX
    PBX
    PN-4COT Card
    PN-TNTA Card
    PN-CP03 Card
    JACK
    External Tone Source Equipment
    External Tone Source Equipment
    * Rating for the Diode
    • VR
    • IO
    • VFLess than-50 V
    More than 20 mA
    Less then 1.0 V
    JACK0
    JACK1
    External Tone Source Equipment 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 1 26
    Revision 2.0
    (b) MDF Cross Connection
    Figure 007-33  MDF Cross Connection for External Tone Source Equipment (1 of 2)
    NAP 200-007
    Sheet 41/56
    Termination of Cables on the MDF
    29K7294
    K6428
    K5283
    K4327
    K32726
    K126
    2
    1K01
    K22LEN0000
    LEN0002
    PIM0
    P PN-DK00
    LT 0 0LT C 0
    J
    33338
    832
    327
    731
    3130
    30
    6
    55
    6
    PN-4COT
    PZ-PW86
    MDF
    G
    Ring
    TipCONTROL
    CIRCUIT
    SPEECH
    PAT H
    CIRCUIT
    G
    LT 0 1
    T3
    R3
    T2
    R2
    T1
    T0
    R0
    R1
    LEN0004     (No. 0)
    LEN0005     (No. 1)
    LEN0006     (No. 2)
    LEN0007     (No. 3)
    K0EXTERNAL TONE SOURCE
    EQUIPMENT 
    						
    							ND-45492 (E) CHAPTER 3
    Page 127
    Revision 2.0
    Figure 007-34  MDF Cross Connection for External Tone Source Equipment (2 of 2)
    NAP 200-007
    Sheet 42/56
    Termination of Cables on the MDF
    26 1 K0
    27 2
    28 3
    29 4
    30 T0 5 R0
    31 6
    32 7
    33 8
    LTC0 (J)
    1K026
    227
    328
    429
    5R030T0
    631
    732
    833
    (P)
    LEN0004
    LEN0005
    LEN0006
    LEN0007
    LEN0000
    LEN0002 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 1 28
    Revision 2.0
    • If a D.C. voltage is supplied with the tone from the external tone source equipment, a transformer or cou-
    pling capacitor should be used as shown in Figure 007-35.
    Figure 007-35  Connecting a Tone Source Supplied with D.C.
    NAP 200-007
    Sheet 43/56
    Termination of Cables on the MDF
    TO PBXTO COTRing
    Tip
    KTRANSFORMER
    SOURCE
    CAPACITOR
    SOURCE
    TO COT
    Tip
    K Ring
    TO CONTROL CIRCUIT
    FROM PN-DK00
    2 µF
    TO PBXTO CONTROL CIRCUIT
    FROM PN-DK00CAPACITOR
    2 µF
    R
    R
    EXTERNAL EQUIPMENT
    EXTERNAL EQUIPMENTDC
    VOLTAGE
    SOURCE
    DC
    VOLTAGE
    SOURCE 
    						
    							ND-45492 (E) CHAPTER 3
    Page 129
    Revision 2.0
    (12) External BGM Source
    The cross connection for customer-owned external BGM sources is shown in Figure 007-36 and Figure
    007-37.  A maximum of 10 BGM sources can be provided in the system.
    (a) When using PN-4COT
    Figure 007-36  MDF Cross Connection for External BGM Sources
    NAP 200-007
    Sheet 44/56
    Termination of Cables on the MDF
    BGM SOURCE
    #0
    29294
    428
    283
    327
    2726
    26
    2 1
    LEN0000
    LEN0001
    LEN0002
    LEN0003MDF
    1
    2
    PIM0
    P PN-4COT
    LT 0 0LT C 0
    J
    T3
    R3
    T2
    R2
    T1
    T0
    R0
    R1
    LEN0000
    LEN0001
    LEN0002
    LEN0003
    BGM SOURCE
    #0
    #1
    1R026T0
    2R127T1
    3R228T2
    4R329T3
    (P)
    26 T0 1 R0
    27 T1 2 R1
    28 T2 3 R2
    29 T3 4 R3
    LTC0 (J) 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 1 30
    Revision 2.0
    (b) When using Pin Jacks on PN-TNTA
    Figure 007-37  Cable Connection between PN-TNTA and External BGM Sources
    NAP 200-007
    Sheet 45/56
    Termination of Cables on the MDF
    PN-TNTA
    JACK0
    JACK1BGM SOURCE
    BGM SOURCE
    # 0
    # 1 
    						
    							ND-45492 (E) CHAPTER 3
    Page 131
    Revision 2.0
    (13) Power Failure Transfer (PFT)
    The PN-AUCA card or the PZ-8PFTA card can be used as the PFT card.
    (a) When using PN-AUCA card
    • An outline of a PFT (PN-AUCA) connection is shown in Figure 007-38.
    • The MDF cross connection for a PFT (PN-AUCA) is shown in Figure 007-39.
     
    Figure 007-38  Outline of the PFT (PN-AUCA) Connection
    NAP 200-007
    Sheet 46/56
    Termination of Cables on the MDF
    MDF TEL
    PN-AUCAPBX
    MDF
    PN-4COTTO C.O. L INE 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 1 32
    Revision 2.0
    Figure 007-39  MDF Cross Connection for the PFT (PN-AUCA) (1 of 2)
    NAP 200-007
    Sheet 47/56
    Termination of Cables on the MDF
    Ring
    Tip
    Ring
    TipTO 
    C.O.
    TO 
    C.O. 1 
    26 
    2 
    27
    3 
    28 
    4 
    29 C.O.R0 
    C.O.T0 
    C.O.R1 
    C.O.T1
    3 
    28 
    4 
    291 
    26 
    2 
    27MDF P JLTC0
    LEN0000 (No. 0)
    LEN0001 (No. 1)
    Ring
    Tip
    Ring
    TipTO 
    ST
    TO 
    ST 5 
    30 
    6 
    31
    7 
    32 
    8 
    33 Sta. R0 
    Sta. T0 
    Sta. R1 
    Sta. T1
    7 
    32 
    8 
    335 
    30 
    6 
    31
    LEN0004 (No. 0)
    LEN0005 (No. 1)
    04 
    03 
    02 
    01
    04 
    03 
    02 
    01PN-4COT
    CN1 LT00
    LT01
    4Q-TW-0.3
    CN1
    PIM0
    PN-AUCA 
    						
    							ND-45492 (E) CHAPTER 3
    Page 133
    Revision 2.0
    Figure 007-40  MDF Cross Connection for the PFT (PN-AUCA) (2 of 2)
    Note 1:
    The No. 2 and No. 3 circuit in the PN-4COT card can not be used with the PFT function.
    Note 2:When using Ground Start trunks with the PFT function, the single line stations must have a ground sending
    button and a ground lead must be run to the station.
    NAP 200-007
    Sheet 48/56
    Termination of Cables on the MDF
    1 C.O.R0 26 C.O.T0
    2 C.O.R1 27 C.O.T1
    328
    429
    5 Sta.R0 3 0 Sta.T0
    6 Sta.R1 3 1 Sta.T1
    732
    83326 C.O.T0 1 C.O.R0
    27 C.O.T1 2 C.O.R1
    28 3
    29 4
    3 0 Sta.T0 5 Sta.R0
    3 1 Sta.T1 6 Sta.R1
    32 7
    33 8
    LTC0 (J)
    LEN0004
    LEN0005
    LEN0000
    LEN0001
    (P) 
    						