Home > NEC > Communications System > NEC Neax 2000 Ivs Installation Procedure Manual

NEC Neax 2000 Ivs Installation Procedure Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs Installation Procedure Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER 3 ND-45492 (E)
    Pag e 9 4
    Revision 2.0
    (f) PIM5 (LTC0 ~ LTC2)
    Figure 007-9  LTC Connector Pin Arrangement (6 of 8)
    NAP 200-007
    Sheet 9/56
    Termination of Cables on the MDF
    LTC2
    26 1 LEN0368
    LT12/AP2 27 2 0369
    28 3 0370
    29 4 0371
    30 5 0372
    LT13/AP3 31 6 0373
    32 7 0374
    33 8 0375
    34 9 0376
    LT14/AP4 35 10 0377
    36 11 0378
    37 12 0379
    38 13 0380
    LT15/AP5 39 14 0381
    40 15 0382
    41 16 LEN0383
    42 17
    AP6
    Note43 18
    44 19
    45 20
    46 21
    47 22
    48 23
    49 24
    50 25
    LTC0
    26 1 LEN0320
    LT00 27 2 0321
    28 3 0322
    29 4 0323
    30 5 0324
    LT01 31 6 0325
    32 7 0326
    33 8 0327
    34 9 0328
    LT02 35 10 0329
    36 11 0330
    37 12 0331
    38 13 0332
    LT03 39 14 0333
    40 15 0334
    41 16 0335
    42 17 0336
    LT04 43 18 0337
    44 19 0338
    45 20 0339
    46 21 0340
    LT05 47 22 0341
    48 23 0342
    49 24 LEN0343
    50 25
    LTC1
    26 1 LEN0344
    LT06 27 2 0345
    28 3 0346
    29 4 0347
    30 5 0348
    LT07 31 6 0349
    32 7 0350
    33 8 0351
    34 9 0352
    LT08 35 10 0353
    36 11 0354
    37 12 0355
    38 13 0356
    LT09 39 14 0357
    40 15 0358
    41 16 0359
    42 17 0360
    LT10/AP0 43 18 0361
    44 19 0362
    45 20 0363
    46 21 0364
    LT11/AP1 47 22 0365
    48 23 0366
    49 24 LEN0367
    50 25
    Note:These pins are used only for the PN-24DTA. 
    						
    							ND-45492 (E) CHAPTER 3
    Page 95
    Revision 2.0
    (g) PIM6 (LTC0 ~ LTC2)
    Figure 007-10  LTC Connector Pin Arrangement  (7 of 8)
    NAP 200-007
    Sheet 10/56
    Termination of Cables on the MDF
    LTC2
    26 1 LEN0432
    LT12/AP2 27 2 0433
    28 3 0434
    29 4 0435
    30 5 0436
    LT13/AP3 31 6 0437
    32 7 0438
    33 8 0439
    34 9 0440
    LT14/AP4 35 10 0441
    36 11 0442
    37 12 0443
    38 13 0444
    LT15/AP5 39 14 0445
    40 15 0446
    41 16 LEN0447
    42 17
    AP6
    Note43 18
    44 19
    45 20
    46 21
    47 22
    48 23
    49 24
    50 25
    LTC0
    26 1 LEN0384
    LT00 27 2 0385
    28 3 0386
    29 4 0387
    30 5 0388
    LT01 31 6 0389
    32 7 0390
    33 8 0391
    34 9 0392
    LT02 35 10 0393
    36 11 0394
    37 12 0395
    38 13 0396
    LT03 39 14 0397
    40 15 0398
    41 16 0399
    42 17 0400
    LT04 43 18 0401
    44 19 0402
    45 20 0403
    46 21 0404
    LT05 47 22 0405
    48 23 0406
    49 24 LEN0407
    50 25
    LTC1
    26 1 LEN0408
    LT06 27 2 0409
    28 3 0410
    29 4 0411
    30 5 0412
    LT07 31 6 0413
    32 7 0414
    33 8 0415
    34 9 0416
    LT08 35 10 0417
    36 11 0418
    37 12 0419
    38 13 0420
    LT09 39 14 0421
    40 15 0422
    41 16 0423
    42 17 0424
    LT10/AP0 43 18 0425
    44 19 0426
    45 20 0427
    46 21 0428
    LT11/AP1 47 22 0429
    48 23 0430
    49 24 LEN0431
    50 25
    Note:These pins are used only for the PN-24DTA. 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 9 6
    Revision 2.0
    (h) PIM7 (LTC0 ~ LTC2)
    Figure 007-11  LTC Connector Pin Arrangement (8 of 8)
    NAP 200-007
    Sheet 11/56
    Termination of Cables on the MDF
    LTC2
    26 1 LEN0496
    LT12/AP2 27 2 0497
    28 3 0498
    29 4 0499
    30 5 0500
    LT13/AP3 31 6 0501
    32 7 0502
    33 8 0503
    34 9 0504
    LT14/AP4 35 10 0505
    36 11 0506
    37 12 0507
    38 13 0508
    LT15/AP5 39 14 0509
    40 15 0510
    41 16 LEN0511
    42 17
    AP6
    Note43 18
    44 19
    45 20
    46 21
    47 22
    48 23
    49 24
    50 25
    LTC0
    26 1 LEN0448
    LT00 27 2 0449
    28 3 0450
    29 4 0451
    30 5 0452
    LT01 31 6 0453
    32 7 0454
    33 8 0455
    34 9 0456
    LT02 35 10 0457
    36 11 0458
    37 12 0459
    38 13 0460
    LT03 39 14 0461
    40 15 0462
    41 16 0463
    42 17 0464
    LT04 43 18 0465
    44 19 0466
    45 20 0467
    46 21 0468
    LT05 47 22 0469
    48 23 0470
    49 24 LEN0471
    50 25
    LTC1
    26 1 LEN0472
    LT06 27 2 0473
    28 3 0474
    29 4 0475
    30 5 0476
    LT07 31 6 0477
    32 7 0478
    33 8 0479
    34 9 0480
    LT08 35 10 0481
    36 11 0482
    37 12 0483
    38 13 0484
    LT09 39 14 0485
    40 15 0486
    41 16 0487
    42 17 0488
    LT10/AP0 43 18 0489
    44 19 0490
    45 20 0491
    46 21 0492
    LT11/AP1 47 22 0493
    48 23 0494
    49 24 LEN0495
    50 25
    Note:These pins are used only for the PN-24DTA. 
    						
    							ND-45492 (E) CHAPTER 3
    Page 97
    Revision 2.0
    2. MDF Cross Connections
    Cross connections on the MDF for LTC0 through LTC2 are shown in Table 007-2 through Table 007-5.
    NAP 200-007
    Sheet 12/56
    Termination of Cables on the MDF
    Table 007-2  LTC0-LTC2 MDF Cross Connection Information (1 of 4)
    PINRUNNING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    CO
    (4COT)CO
    (2COT)2-WIRE 
    E&M TIE 
    LINE 
    (2ODT)4-WIRE 
    E&M TIE 
    LINE 
    (2ODT)DID
    (AUC)SLT
     (4LC)SLT
    (AUC)
    26 WH-BL GN
    1T0 T0 T0 TxT0 T0 T0 T0
    1 BL-WH RD R0 R0 R0 TxR0 R0 R0 R0
    27 WH-OR BK T1 T1 T1 RcvT0 T1 T1 T1
    2 OR-WH YL R1 R1 R1 RcvR0 R1 R1 R1
    28 WH-GN GN T2 T2 TxT1 T2
    3 GN-WH RD R2 R2 TxR1 R2
    29 WH-BR BK T3 T3 RcvT1 T3
    4 BR-WH YL R3 R3 RcvR1 R3
    30 WH-SL GN
    2T0 T0 T0 TxT0 T0 T0 T0
    5 SL-WH RD R0 R0 R0 TxR0 R0 R0 R0
    31 RD-BL BK T1 T1 T1 RcvT0 T1 T1 T1
    6 BL-RD YL R1 R1 R1 RcvR0 R1 R1 R1
    32 RD-OR GN T2 T2 TxT1 T2
    7 OR-RD RD R2 R2 TxR1 R2
    33 RD-GN BK T3 T3 RcvT1 T3
    8 GN-RD YL R3 R3 RcvR1 R3
    34 RD-BR GN
    3T0 T0 T0 TxT0 T0 T0 T0
    9 BR-RD RD R0 R0 R0 TxR0 R0 R0 R0
    35 RD-SL BK T1 T1 T1 RcvT0 T1 T1 T1
    10 SL-RD YL R1 R1 R1 RcvR0 R1 R1 R1
    36 BK-BL GN T2 T2 TxT1 T2
    11 BL-BK RD R2 R2 TxR1 R2
    37 BK-OR BK T3 T3 RcvT1 T3
    12 OR-BK YL R3 R3 RcvR1 R3 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 9 8
    Revision 2.0
    * Major and minor alarm connections for external indications are located on LTC0 of PIM0, only.
    NAP 200-007
    Sheet 13/56
    Termination of Cables on the MDF
    Table 007-3  LTC0-LTC2 MDF Cross Connection Information (2 of 4)
    PINRUNNING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    COT
    (4COT)COT
    (2COT)2-WIRE 
    E&M TIE 
    LINE 
    (2ODT)4-WIRE 
    E&M TIE 
    LINE 
    (2ODT)DID
    (AUC)SLT
     (4LC)SLT
    (AUC)
    38 BK-GN GN
    4T0 T0 T0 TxT0 T0 T0 T0
    13 GN-BK RD R0 R0 R0 TxR0 R0 R0 R0
    39 BK-BR BK T1 T1 T1 RcvT0 T1 T1 T1
    14 BR-BK YL R1 R1 R1 RcvR0 R1 R1 R1
    40 BK-SL GN T2 T2 TxT1 T2
    15 SL-BK RD R2 R2 TxR1 R2
    41 YL-BL BK T3 T3 RcvT1 T3
    16 BL-YL YL R3 R3 RcvR1 R3
    42 YL-OR GN
    5T0 T0 T0 TxT0 T0 T0 T0
    17OR-YL RD R0R0 R0 TxR0R0R0R0
    43 YL-GN BK T1 T1 T1 RcvT0 T1 T1 T1
    18 GN-YL YL R1 R1 R1 RcvR0 R1 R1 R1
    44 YL-BR GN T2 T2 TxT1 T2
    19 BR-YL RD R2 R2 TxR1 R2
    45 YL-SL BK T3 T3 RcvT1 T3
    20 SL-YL YL R3 R3 RcvR1 R3
    46 VI-BL GN
    6T0 T0 T0 TxT0 T0 T0 T0
    21BL-VI RD R0R0 R0 TxR0R0R0R0
    47 VI-OR BK T1 T1 T1 RcvT0 T1 T1 T1
    22 OR-VI YL R1 R1 R1 RcvR0 R1 R1 R1
    48 VI-GN GN T2 T2 TxT1 T2
    23 GN-VI RD R2 R2 TxR1 R2
    49 VI-BR BK T3 T3 RcvT1 T3
    24 BR-VI YL R3 R3 RcvR1 R3
    50 VI-SL MN 
    *
    25 SL-VI MJ 
    * 
    						
    							ND-45492 (E) CHAPTER 3
    Page 99
    Revision 2.0
    Note 1:2 wire type for Multiline Terminal/DSS Consol/SN716 DESKCON.
    Note 2:4 wire type for Multiline Terminal/SN610 ATTCON.
    NAP 200-007
    Sheet 14/56
    Termination of Cables on the MDF
    Table 007-4  LTC0-LTC2 MDF Cross Connection Information (3 of 4)
    PINRU NN ING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    D
    term/
    SN716 
    DESKCON 
    (4DLC) 
    Note 1Dterm/
    SN716 
    DESKCON 
    (2DLC) 
    Note 1Dterm 
    (4DLC) 
    Note 2SN610 
    AT T C O N  
    (2DLC) 
    Note 2EXT. KEY/
    EXT.
    RELAY
    (DK00)EXT.
    PAG E / M O H /
    BGM 
    (4COT)
    26
    1WH-BL
    BL-WHGN
    RD
    1T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    27
    2WH-OR
    OR-WHBK
    YLT1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    28
    3WH-GN
    GN-WHGN
    RDT2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    29
    4WH-BR
    BR-WHBK
    YLT3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    30
    5WH-SL
    SL-WHGN
    RD
    2T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    31
    6RD-BL
    BL-RDBK
    YLT1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    32
    7RD-OR
    OR-RDGN
    RDT2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    33
    8RD-GN
    GN-RDBK
    YLT3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    34
    9RD-BR
    BR-RDGN
    RD
    3T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    35
    10RD-SL
    SL-RDBK
    YLT1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    36
    11BK-BL
    BL-BKGN
    RDT2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    37
    12BK-OR
    OR-BKBK
    YLT3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 1 00
    Revision 2.0
    * Major and minor alarm connections for external indications are located on LTC0 of PIM0, only.
    Note 1:2 wire type for Multiline Terminal/DSS Consol/SN716 DESKCON.
    Note 2:4 wire type for Multiline Terminal/SN610 ATTCON.
    NAP 200-007
    Sheet 15/56
    Termination of Cables on the MDF
    Table 007-5  LTC0-LTC2 MDF Cross Connection Information (4 of 4)
    PINRUNNING
    CABLESTATION
    CABLESLOTSTYPE OF INTERFACE
    D
    term/
    SN716 
    DESKCON 
    (4DLC) 
    Note 1Dterm/
    SN716 
    DESKCON 
    (2DLC) 
    Note 1Dterm 
    (4DLC) 
    Note 2SN610 
    ATTCON 
    (2DLC) 
    Note 2EXT. KEY/
    EXT. 
    RELAY
    (DK00)EXT.
    PA G E / M O H /
    BGM
    (4COT)
    38
    13BK-GN
    GN-BKGN
    RD
    4T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    39
    14BK-BR
    BR-BKBK
    YLT1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    40
    15BK-SL
    SL-BKGN
    RDT2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    41
    16YL-BL
    BL-YLBK
    YLT3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    42
    17YL-OR
    OR-YLGN
    RD
    5T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    43
    18YL-GN
    GN-YLBK
    YLT1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    44
    19YL-BR
    BR-YLGN
    RDT2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    45
    20YL-SL
    SL-YLBK
    YLT3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    46
    21VI-BL
    BL-VIGN
    RD
    6T0
    R0T0
    R0RA0
    TA 0RA0
    TA 0K1
    K0T
    R
    47
    22VI-OR
    OR-VIBK
    YLT1
    R1T1
    R1RB0
    TB0RB0
    TB0K3
    K2T
    R
    48
    23VI-GN
    GN-VIGN
    RDT2
    R2RA1
    TA 1RA1
    TA 1K5
    K4T
    R
    49
    24VI-BR
    BR-VIBK
    YLT3
    R3RB1
    TB1RB1
    TB1K7
    K6T
    R
    50
    25VI-SL
    SL-VIMN*
    MJ* 
    						
    							ND-45492 (E) CHAPTER 3
    Page 101
    Revision 2.0
    (1) C.O. Trunk
    (a) 4 Line C.O. Trunk (PN-4COT)
    Figure 007-12  MDF Cross Connection for a 4 Line C.O. Trunk Card (PN-4COT)
    NAP 200-007
    Sheet 16/56
    Termination of Cables on the MDF
    29T3294
    R3428
    T2283
    R2327
    T12726
    T026
    2
    1
    1R0 26T0
    2R127T1
    3
    R228T2
    4
    R329T3
    (P)
    26 T0 1 R0
    27T12R1
    28
    T23R2
    29
    T34R3
    LEN0000
    LEN0001
    LEN0002
    LEN0003
    LTC0 (J)MDF
    R01
    R12
    LEN0000      (No. 0)
    LEN0001      (No. 1)
    LEN0002      (No. 2)
    LEN0003      (No. 3)
    TO C.O. L INE
    TO C.O. L INE
    TO C.O. L INE
    TO C.O. L INE
    PIM0
    P PN-4COT
    LT 0 0LT C 0
    J 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 1 02
    Revision 2.0
    (2) Tie Line Trunk
    (a) 4W E&M (PN-2ODT)
    Figure 007-13  MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT) (1 of 2)
    NAP 200-007
    Sheet 17/56
    Termination of Cables on the MDF
    Note 1:Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT card.
    Note 2:When connecting the E and M, make the installation cable by using the connector attached with the 
    PN-2ODT card.
    PIM0
    08 
    07 
    06 
    05 
    04 
    03 
    02 
    01M1 
    E1 
    M0 
    E0
    LEN0001 (No. 1)
    LEN0000 (No. 0)
    TxR0 
    TxT0 
    RcvR0 
    RcvT0 
    TxR1 
    TxT1 
    RcvR1 
    RcvT11 
    26 
    2 
    27 
    3 
    28 
    4 
    29
    LT00
    LEN0001 (No. 1) LEN0000 (No. 0)
    PN-2ODT
    CN1
    1 
    26 
    2 
    27 
    3 
    28 
    4 
    29(Tx Ring) 
    (Tx Tip) 
    (Rcv Ring) 
    (Rcv Tip) (M) 
    (E)
    JPLTC0
    TO TIE LINE
    MDF
    INSTALLATION CABLE 
    						
    							ND-45492 (E) CHAPTER 3
    Page 103
    Revision 2.0
    Figure 007-14  MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT) (2 of 2)
    NAP 200-007
    Sheet 18/56
    Termination of Cables on the MDF
    M1
    E1
    M0
    E0LEN0001
    LEN0000
    CN1
    1 LTC CONNECTOR2 CN1 CONNECTOR
    (FRONT CONNECTOR)
    LEN0000
    LEN00011 TxR0 26 TxT0
    2 RcvR0 27 RcvT0
    3 TxR1 28 TxT1
    4 RcvR1 29 RcvT1
    (P)
    26 TxT0 1 TxR0
    27 RcvT0 2 RcvR0
    28 TxT1 3 TxR1
    29 RcvT1 4 RcvR1
    LTC0 (J) 
    						
    All NEC manuals Comments (0)