NEC Neax 2000 Ivs Installation Procedure Manual
Have a look at the manual NEC Neax 2000 Ivs Installation Procedure Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
LIST OF TABLES ND-45492 (E) Pag e v i Revision 2.0 LIST OF TABLES Table TitlePag e Table 2-1 Description of Symbols in Trunking Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Table 3-1 Procedure for Unplugging/Plugging Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 003-1 Recommended Fasteners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Table 006-1 MDF Cables for each PIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Table 007-1 LTC Connector Accommodation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Table 007-2 LTC0-LTC2 MDF Cross Connection Information (1 of 4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Table 007-3 LTC0-LTC2 MDF Cross Connection Information (2 of 4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Table 007-4 LTC0-LTC2 MDF Cross Connection Information (3 of 4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Table 007-5 LTC0-LTC2 MDF Cross Connection Information (4 of 4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
ND-45492 (E) SAFETY CONSIDERATIONS Page vii Revision 2.0 SAFETY CONSIDERATIONS IMPORTANT — SAVE THESE INSTRUCTIONS (1) Never install telephone wiring during a lightning storm. (2) Never install telephone jacks in wet locations unless the jack is specifically designed for wet loca- tions. (3) Never touch uninsulated telephone wires or terminals unless the telephone line has been discon- nected at the network interface. (4) Use caution when installing or moving telephone lines. When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury, including the following: (5) Read and understand all instructions. (6) Follow all warnings and instructions marked on the product. (7) Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. (8) Do not use this product near water; for example, under water pipes near a bath tub, sink, or laun- dry tub, in a wet basement, or near a swimming pool. (9) Do not place this product on an unstable cart, stand, or table. The product may fall, causing seri- ous damage to the product. (10) Slots and openings in the cabinet and the back or bottom are provided for ventilation, to protect it from overheating. These openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register. This product should not be placed in a built-in installation unless proper ventilation is provided. (11) This product should be operated only from the type of power source indicated on the marking la- bel. If you are not sure of the type of power source available, consult with your local power com- pany. (12) This product normally connected with a three wire grounding type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact an electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding type plug. (13) Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by persons walking on it. (14) Do not overload wall outlets and extension cords as this can result in the risk of fire or electric
SAFETY CONSIDERATIONS ND-45492 (E) Pag e v iii Revision 2.0 shock. (15) Never push objects of any kind into this product through cabinet slots as they may touch danger- ous voltage points or shor t out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product. (16) To reduce the risk of electric shock, do not disassemble this product, but take it to a qualified ser- viceman when some service or repair work is required. Opening or removing covers may expose you to dangerous voltages or other risks. Incorrect reassembly can cause electric shock when the appliance is subsequently used. (17) Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: (a) When the power supply cord or plug is damaged or frayed. (b) If liquid has been spilled into the product. (c) If the product has been exposed to rain or water. (d) If the product does not operate normally by following the operating instructions. Adjust only those controls, that are covered by the operating instructions because improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation. (e) If the product has been dropped or the cabinet has been damaged. (f) If the product exhibits a distinct change in performance. (18) Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. (19) Do not use the telephone to report a gas leak in the vicinity of the leak.
ND-45492 (E) REGULATORY INFORMATION Page ix Revision 2.0 REGULATORY INFORMATION 1. Regulatory Requirements The Federal Communications Commission (FCC) has established rules that permit the NEAX2000 IVS to be directly connected to the telephone network. A jack is provided on party lines or coin lines. The telephone company may make changes in its technical operations and procedures. If such changes affect the compatibility or use of the NEAX2000 IVS, the telephone company is required to give adequate notice of the changes. This equipment complies with the requirements in Part 15 of FCC Rules for a Class A computing device. Op- eration of this equipment in a residential area may cause unacceptable interference to radio and TV reception requiring the operator to take whatever steps are necessary to correct this interference. 2. FCC Part 15 Requirements In compliance with FCC Part 15 Rules, the following statement is provided: 3. FCC Part 68 Registration 3.1 Company Notification Before installing the NEAX2000 IVS to the telephone network, the telephone company must be provided with the following: • Your telephone number • The FCC registration numbers: JA PA N U S A • PBX: AY5JPN-20542-PF-E AY5USA-21582-PF-E • Hybrid: AY5JPN-20543-MF-E AY5USA-21583-MF-E • Key system: AY5JPN-20586-KF-E AY5USA-21584-KF-E The Ringer Equivalence Number is 1.6B; the required USOC jacks are RJ21X, RJ2EX, and RJ2GX.WARNING This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause in- terference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interfer- ence when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to cor- rect the interference.
REGULATORY INFORMATION ND-45492 (E) Pag e x Revision 2.0 NOTE: Limitations on features exist if the system is registered as a KF system. Refer to Features and Specifi- cations for details. 3.2 Service Requirements In the event of equipment malfunction, all repairs will be performed by NEC or an authorized distributor of NEC. It is the responsibility of users requiring service to report the need for service to NEC or to one of their authorized distributors. If the equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications in order to maintain uninterrupted service. If trouble is experienced with this equipment, please contact NEC America, Inc.’s Oregon plant at (503) 648- 5000 for repair and/or warranty information. If the trouble is causing harm to the telephone network, the tele- phone company may request that you remove the equipment from the network until the problem is resolved. NO REPAIRS CAN BE DONE BY THE CUSTOMER. 3.3 Location of FCC Compliance Labels Labels stating the NEAX2000 IVS FCC registration number and compliance with FCC Parts 15 and 68 are at- tached to the Base Unit. If the unit is in a table-top configuration, the labels are located on the side of the enclo- sure. The appearance of the labels is as shown below: 4. Direct-Inward Dialing (DID) Calls Allowing this equipment to be operated in such a manner as to not provide for proper answer supervision is a violation of Part 68 of the FCC’s rules. PROPER ANSWER SUPERVISION IS WHEN: (a) This equipment returns answer supervision to the PSTN when DID calls are: • Answered by the called station • Answered by the attendant NEAX2000 IVS COMPLIES WITH PART 68 FCC RULES FCC registration numbers: AY5USA-21582-PF-E AY5USA-21583-MF-E AY5USA-21584-KF-E Ringer Equivalence : 1.6B NEC NEC America Made In U.S.A.
ND-45492 (E) REGULATORY INFORMATION Page xi Revision 2.0 • Routed to a recorded announcement that can be administered by the CPE user • Routed to a dial prompt (b) This equipment returns answer supervision on all DID calls forwarded to the PSTN. Permissible ex- ceptions are: • A call is unanswered • A busy tone is received • A reorder tone is received. EQUAL ACCESS REQUIREMENTS This equipment is capable of providing users access to interstate providers of operator services through the use of access codes. Modification of this equipment by call aggregators to block access dialing codes is a violation of the Telephone Operator Consumers Act of 1990. 5. Regulatory Information on Single-Line Analog Telephones NEC single-line telephones comply with Part 68 of FCC Rules. On the bottom of the equipment is a label that states, among other information, the FCC registration number and ringer equivalence number (REN) for the equipment. If requested, this information should be provided to the telephone company. The equipment uses the following USOC jacks: RJ11C. The equipment should be used only behind a PBX or KTS. The REN is used to determine the quantity of devices that may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all, areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area. 6. Hearing Aid Compatibility The D term terminals provided for the NEAX2000 IVS are hearing aid compatible. FCC rules prohibit the use of non-hearing aid compatible telephones. NEC-type single-line telephone sets used in conjunction with the NEAX2000 IVS are hearing aid compatible. If other than NEC-type single-line telephone sets are to be used with this system, ensure that these are hearing aid compatible. CAUTION:The act of monitoring or recording telephone conversations under certain circumstances may vi- olate federal or state statutes. Consultation with your legal counsel prior to engaging in such prac- tices would be advisable. 7. Industry Canada CS-03 Certification number: 140 5976A Load Number of the equipment: 21
REGULATORY INFORMATION ND-45492 (E) Pag e x ii Revision 2.0 NOTICE: The Industry Canada label identifies certified equipment. The certification means that the equipment meets certain telecommunications network protective operational and safety requirements. The department does not guarantee the equipment will operate to the user’s satisfaction. Before installing the equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of con- nection. In some cases, the company’s inside wiring associated with a single line individual service may be ex- tended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or installations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request that the user disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, tele- phone lines, and internal metallic water pipe system, if present, are connected together. This protection may be particularly important in rural areas. CAUTION:Users should not attempt to make such connections themselves, but should contact the appropri- ate electric inspection authority, or electrician, as appropriate. NOTICE: The Load Number assigned to each terminal device denotes the percentage of the total load to be con- nected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the load numbers of all the devices does not exceed 100. 8. Safety Certifications This equipment has been listed by Underwriters Laboratories and found to comply with all the applicable re- quirements of the standard for telephone equipment U.L. 1459. This equipment complies with Canadian Stan- dards Association’s standard C 22.2 No. 225. 8.1 Safety Considerations When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury, including the following: 1. Never install telephone wiring during a lightning storm. 2. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. 3. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. 4. Use caution when installing or modifying telephone lines. NOTE: Also follow the precautionary items listed under “Safety Considerations” on the previous pages.
ND -4 5492 ( E) CHAPTER 1 CHAPTER 1 INTRODUC TION C IRCUIT CARD MAN UAL M AINTEN ANCE MAN UAL COM MAND MAN UA L SYS TEM D ATA S HEET CIRCUIT CAR D DESCR IPTION D ESCRIP TION
CHAPTER 1 ND-45492 (E) Pag e 2 Revision 2.0 3. HOW TO FOLLOW THIS MANUAL The Installation Procedure is shown by means of flowcharts with NEC Action Procedure (NAP) numbers. The details of each step are described in the NAPs. 3.1 SCOPE OF INSTALLATION PROCEDURES This manual covers the installation shown in Figure 1-2. Figure 1-2 Scope of Installation Works NAP- 200-003: INSTALLATION OF MAIN EQUIPMENT NAP- 200-008: MOUNTING OF CIRCUIT CARDSNAP- 200-004: INSTALLATION OF PERIPHERAL EQUIPMENT SN610 ATTCON MDF MDF CABLE NAP- 200-006: CABLE RUNNING TO MDF NAP- 200-007: TERMINATION OF CABLES ON MDF Dterm TO C.O. LINE, TIE LINE SINGLE LINE TELEPHONE TO TAS INDICATOR, ALM INDICATOR BATTERY NAP- 200-005: CONNECTION OF BATTERY SN716 DESKCON
ND-45492 (E) CHAPTER 2 Page 3 Revision 2.0 CHAPTER 2 GENERAL INFORMATION 1. TRUNKING DIAGRAM A typical trunking diagram for the PBX is shown in Figure 2-1. Figure 2-1 PBX Trunking Diagram MODEM Note 1:An external Modem is not required when the Built-In Modem on the MP is used. Note 2:The equipment marked with (*) is provided by the customer. Note 3:The MP functions marked with (**) are included in the PN-CP03 card only. 4W E&M 2W E&M RS 232C V. 1 1 TCP/IP V. 1 1 RS-232C RS 232C LONG LINE STATION SINGLE LINE TELEPHONE VOICE MAIL SYSTEM Dterm DSS Dterm LONG LINE DSS SN610 ATTCON SMDR PMS HOTEL PRINTER PC FOR OAI AND ACD-MIS PC FOR OAI DTE MAT FROM LC (FOR REMOTE MAINTENANCE) Note 1 DPC ETHER AP01 AP00 DLCC/DLCF DLCB/DLCN DLC LCJ LCD AU C PFT MP INCLUDING SW DTG PBSND 16CFT MLDT PLO MEM MODEM PBR** TNT** SMDR**COT AUC/DIT OD T OD T DTI CCH DCH PBR DAT PLO MFR CFT DK COT COT COT COT/TNT TNT EXTERNAL HOLD TONE(*)(*)SPEAKER(*) AMP(*) EXTERNAL HOLD TONE(*) ANNOUNCEMENT MACHINE(*) KEY(*)6/10 PARTY CONFERENCE DIGITAL LINK ISDN NETWORK TIE LINE DID LINE C.O. LINE SN716 DESKCONDLC