Home > NEC > Communications System > NEC Neax 2000 Ivs Installation Procedure Manual

NEC Neax 2000 Ivs Installation Procedure Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs Installation Procedure Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER 3 ND-45492 (E)
    Pag e 1 04
    Revision 2.0
    (b) 2W E&M (PN-2ODT)
    Figure 007-15  MDF Cross Connection for a 2W E&M Trunk Card (PN-2ODT) (1 of 2)
    NAP 200-007
    Sheet 19/56
    Termination of Cables on the MDF
    Note 1:Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT card.
    Note 2:When connecting the E and M, make the installation cable by using the connector attached with the 
    PN-2ODT card. 
    PIM0
    08 
    07 
    06 
    05 
    04 
    03 
    02 
    01M1 
    E1 
    M0 
    E0
    LEN0001 (No. 1)
    LEN0000 (No. 0)
    R0 
    T0 
    R1 
    T1 1 
    26 
    3 
    28 
    LT00
    LEN0001 (No. 1) LEN0000 (No. 0)
    PN-2ODT
    CN1
    TO-10 
    TO-9
    1 
    26 
    3 
    28 (Ring) 
    (Tip) (M) 
    (E)
    JPLTC0
    TO TIE LINE
    INSTALLATION CABLE
    MDF 
    						
    							ND-45492 (E) CHAPTER 3
    Page 105
    Revision 2.0
    Figure 007-16  MDF Cross Connection for a 2W E&M Trunk Card (PN-2ODT) (2 of 2)
    NAP 200-007
    Sheet 20/56
    Termination of Cables on the MDF
    M1
    E1
    M0
    E0LEN0001
    LEN0000
    CN1
    1 LTC CONNECTOR2 CN1 CONNECTOR
    (FRONT CONNECTOR)
    LEN0000
    LEN00011R026T0
    227
    3R228T2
    429
    (P)
    26 T0 1 R0
    27 2
    28 T2 3 R2
    29 4
    LTC0 (J) 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 1 06
    Revision 2.0
    (3) DID Trunk
    (a) 2 Line DID Trunk (PN-AUCA)
    Figure 007-17  MDF Cross Connection for a 2 Line DID Trunk Card (PN-AUCA)
    NAP 200-007
    Sheet 21/56
    Termination of Cables on the MDF
    Note:The PN-AUCA card can also be used as a long line circuit with the Power Failure Transfer (PFT)
    function.
    R0 
    T0 
    R1 
    T11 
    26 
    2 
    27 
    3 
    28 
    4 
    29
    LT00
    LEN0001 (No. 1) LEN0000 (No. 0)1 
    26 
    2 
    27 
    3 
    28 
    4 
    29TO DID LINETO DID LINE PIM0
    PN-AUCAJPLTC0
    MDF
    1 
    2 
    3 
    4R0 
    R126 
    27 
    28 
    29T0 
    T1 (P)26 
    27 
    28 
    29T0 
    T11 
    2 
    3 
    4R0 
    R1 LTC0 (J)LEN0000
    LEN0001 
    						
    							ND-45492 (E) CHAPTER 3
    Page 107
    Revision 2.0
    (a) 4 Line DID Trunk (PN-4DITB)
    Figure 007-18  MDF Cross Connection for a 4 Line DID Trunk Card (PN-4DITB)
    NAP 200-007
    Sheet 22/56
    Termination of Cables on the MDF
    R0 
    T0 
    R1 
    T11 
    26 
    2 
    27 
    3 
    28 
    4 
    29
    LT00
    LEN0001 (No. 1) LEN0000 (No. 0)1 
    26 
    2 
    27 
    3 
    28 
    4 
    29TO DID LINETO DID LINE PIM0
    PN-4DITBJPLTC0
    MD F
    1 
    2 
    3 
    4R0 
    R1 
    R2 
    R326 
    27 
    28 
    29T0 
    T1 
    T2 
    T3 (P)26 
    27 
    28 
    29T0 
    T1 
    T2 
    T31 
    2 
    3 
    4R0 
    R1 
    R2 
    R3 LTC0 (J)
    LEN0000 
    LEN0001 
    LEN0002 
    LEN0003
    R2 
    T2 
    R3 
    T3
    LEN0003 (No. 3) LEN0002 (No. 2)
    TO DID LINE
    TO DID LINE 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 1 08
    Revision 2.0
    (4) Single Line Telephone
    (a) Standard Line (PN-4LC)
    Figure 007-19  MDF Cross Connection for a Single Line Telephone (Standard Line)
    NAP 200-007
    Sheet 23/56
    Termination of Cables on the MDF
    29T3294
    R3428
    T2283
    R2327
    T12726
    T026
    2
    1
    1R026T0
    2R127T1
    3R228T2
    4R329T3
    (P)
    26 T0 1 R0
    27 T1 2 R1
    28 T2 3 R2
    29 T3 4 R3LEN0000
    LEN0001
    LEN0002
    LEN0003
    LTC0 (J)MDF
    R01
    R12
    LEN0000       (No. 0)
    PIM0
    P PN-4LC
    LT 0 0LT C 0
    J
    LEN0001       (No. 1)
    LEN0002       (No. 2)
    LEN0003       (No. 3)
    TO SINGLE
    LINE TELEPHONE 
    						
    							ND-45492 (E) CHAPTER 3
    Page 109
    Revision 2.0
    (b) Long Line (PN-AUCA)
    Figure 007-20  MDF Cross Connection for a Single Line Telephone (Long Line) 
    NAP 200-007
    Sheet 24/56
    Termination of Cables on the MDF
    29294
    428
    283
    327
    2726
    26
    2
    1
    LEN0000
    LEN0001MDF
    1
    2
    PIM0
    P PN-AUCA
    LT 0 0LT C 0
    J
    T1
    R1
    T0
    R0
    LEN0000   (No. 0)
    LEN0001   (No. 1)
    TO SINGLE LINE 
    TELEPHONE
    (FOR LONG LINE)
    1 R026T0
    2 R127T1
    328
    429
    (P)
    26 T0 1 R0
    27 T1 2 R1
    28 3
    29 4
    LTC0 (J)
    Note 1:The PN-AUCA card can also be used as a DID Trunk card.
    Note 2: For the cross connection for the Power Failure Transfer (PFT), see item (12) in this NAP.
    TO SINGLE LINE 
    TELEPHONE
    (FOR LONG LINE) 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 1 10
    Revision 2.0
    (5) Dterm /DSS Console
    (a) Standard Line (PN-4DLCA)
    Figure 007-21  MDF Cross Connection for a Dterm/DSS Console (Standard Line)
    NAP 200-007
    Sheet 25/56
    Termination of Cables on the MDF
    29294
    428
    283
    327
    2726
    26
    2
    1
    1R029T0
    2R128T1
    3R227T2
    4R326T3
    (P)
    26 T0 1 R0
    27 T1 2 R1
    28 T2 3 R2
    29 T3 4 R3LEN0000
    LEN0001
    LEN0002
    LEN0003
    LTC0 (J)MDF
    1
    2
    MODULAR TERMINAL
    PIM0
    P PN-4DLCA
    LT 0 0LT C 0
    J
    T3
    R3
    T2
    R2
    T1
    T0
    R0
    R1
    LEN0000   (No. 0)
    LEN0001   (No. 1)
    LEN0002   (No. 2)
    LEN0003   (No. 3)
    TO Dterm/DSS 
    CONSOLE 
    						
    							ND-45492 (E) CHAPTER 3
    Page 111
    Revision 2.0
    (b) Long Line (PN-2DLCB)
    Figure 007-22  MDF Cross Connection for a Dterm/DSS Console (Long Line)
    NAP 200-007
    Sheet 26/56
    Termination of Cables on the MDF
    29294
    428
    283
    327
    2726
    26
    2
    1
    1R029T0
    2R128T1
    327
    426
    (P)
    26 T0 1 R0
    27 T1 2 R1
    28 3
    29 4LEN0000
    LEN0001
    LTC0 (J)MDF
    1
    2
    MODULAR TERMINAL
    PIM0
    P PN-2DLCB
    LT 0 0LT C 0
    J
    T1
    T0
    R0
    R1
    LEN0000   (No. 0)
    LEN0001   (No. 1)
    TO Dterm/DSS 
    CONSOLE 
    						
    							CHAPTER 3 ND-45492 (E)
    Pag e 1 12
    Revision 2.0
    (6) SN610 ATTCON
    (a) When using PN-2DLCC
    Figure 007-23  MDF Cross Connection for an SN610 ATTCON (1 of 3)
    NAP 200-007
    Sheet 27/56
    Termination of Cables on the MDF
    26
    27
    28
    29TA 0
    TB0
    TA 1
    TB11
    2
    3
    4RA0
    RB0
    RA1
    RB1TA 0
    TB0
    TA 1
    TB11
    2
    3
    4RA0
    RB0
    RA1
    RB126
    27
    28
    29
    BLACK
    YELLOW
    GREEN
    LT 0 0
    PN-2DLCC
    PIM0
    LEN0000 (No. 0)
    LEN0001 (No. 1)
    TA 0
    RA0
    TB0
    RB0
    TA 1
    RA1
    TB1
    RB1
    1
    26
    2
    27
    3
    28
    4
    29
    1
    26
    2
    27
    3
    28
    4
    29
    MDF
    RED
    MODULAR TERMINAL
    TO SN610 ATTCON
    LEN0001
    LEN0000
    LTC0 (J) (P) 
    						
    							ND-45492 (E) CHAPTER 3
    Page 113
    Revision 2.0
    (b) When using PN-4DLCF
    Figure 007-23  MDF Cross Connection for an SN610 ATTCON (2 of 3)
    NAP 200-007
    Sheet 28/56
    Termination of Cables on the MDF
    Note:When using the No. 2 and No. 3 circuits of PN-4DLCF card, make the installation cable by using
    the connector attached with the PN-4DLCF card.
    PIM0
    08 
    07 
    06 
    05 
    04 
    03 
    02 
    01
    LEN0003 (No. 3)
    LEN0002 (No. 2)
    TA0 
    RA0 
    TB0 
    RB0 
    TA1 
    RA1 
    TB1 
    RB1 
     1 
    26 
    2 
    27 
    3 
    28 
    4 
    29
    LT00
    LEN0001 (No. 1) LEN0000 (No. 0)
    PN-4DLCF
    CN1
    1 
    26 
    2 
    27 
    3 
    28 
    4 
    29
    RED 
    GREEN 
    YELLOW 
    BLACK
    JPLTC0
    TO SN610 
    ATTCON
    RED 
    GREEN 
    YELLOW 
    BLACK
    MDF
    RB3 
    TB3 
    RA3 
    TA3 
    RB2 
    TB2 
    RA2 
    TA2
    TO SN610 
    ATTCON
    MODULAR TERMINAL MODULAR TERMINAL
    INSTALLATION CABLE 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs Installation Procedure Manual