Page 51
CHAPTER 3 ND-45492 (E) Pag e 3 4 Revision 2.0 (9) Confirm the connection of the PWR CNT CA-A and power output cables as shown in Figure 003-10 (These cables are pre-installed). Figure 003-10 Cable Connection between the PZ-PW86 and the BWB NAP 200-003 Sheet 12/37 Installation of Main Equipment LTC CONNECTOR AREA PIM BWB (Back Wiring Board)PZ-PW86 PWR0B PWR0A RS PWR1 PWR CNT CA-A POWER OUTPUT CABLE (CR,E) POWER OUTPUT CABLE (+5V, -27V, E)CARD SLOT AREA
Page 52
ND-45492 (E) CHAPTER 3 Page 35 Revision 2.0 (10) AC CORD-B and AC Power Cable Wiring (a) The AC CORD-B and the AC Power Cable Wiring to the FG, NEUTRAL and LINE terminals inside the BASE are shown in Figure 003-11 (for details of wiring to the terminals, see Figure 003-12). Figure 003-11 AC CORD-B and AC Power Cable Wiring NAP 200-003 Sheet 13/37 Installation of Main Equipment TO GROUND TERMINAL FRONTSEE FIGURE 003-12AC CORD-B 3P AC POWER CABLE PIM PIM BASE
Page 53
CHAPTER 3 ND-45492 (E) Pag e 3 6 Revision 2.0 (b) Secure the AC CORD-B cables to the FG, NEUTRAL and LINE terminals as shown in Figure 003- 12. The 3P AC Power Cable and the FG Cable are pre-installed with the BASE. Figure 003-12 Screwing the AC CORD-B to the Terminals NAP 200-003 Sheet 14/37 Installation of Main Equipment FG NEUTRAL LINE BASE 3P AC POWER CABLE TO 120/240 V AC SOURCE POWER AC POWER KNOCK OUT HOLE (PROVIDED WITH BASE) FG CABLE (PROVIDED WITH BASE) PIMAC CORD-B TO PZ-PW86 IN PIM...
Page 54
ND-45492 (E) CHAPTER 3 Page 37 Revision 2.0 (c) When the system is a two-frame configuration, the 3P AC Power Cable of the left side frame can go through the BASE of the right side frame, as shown in Figure 003-12. Figure 003-13 AC Power Cable Wiring for Two-Frame Configuration NAP 200-003 Sheet 15/37 Installation of Main Equipment FGNEUTRALLINEFGNEUTRALLINE 3P AC POWER CABLE TO 120/240 V AC SOURCE POWER SUPPLEMENTARY GROUND (TO COLD WATER PIPE, ETC.)
Page 55
CHAPTER 3 ND-45492 (E) Pag e 3 8 Revision 2.0 (11) When the system is a multiple-PIM configuration, connect the PZ-PW86 Cards to each other using PWR CA-A cables, as shown in Figure 003-14 and Figure 003-15. Figure 003-14 PWR CA-A NAP 200-003 Sheet 16/37 Installation of Main Equipment 550mm (21.7 inch) PWR CA-A
Page 56
ND-45492 (E) CHAPTER 3 Page 39 Revision 2.0 (a) When using an External Battery or the BATTM Figure 003-15 Connection of PWR CA-A Cables (1 of 2) NAP 200-003 Sheet 17/37 Installation of Main Equipment PIM7 PIM6 PIM5 PIM4 PIM3 PIM2 PIM1 PIM0PWR CA-APZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 TO BATTERYPZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 TO BATTERY PWR CA-A Note:For details of battery connection, see NAP- 200-005. PWR CA-A PWR...
Page 57
CHAPTER 3 ND-45492 (E) Pag e 4 0 Revision 2.0 (b) When using an Internal Battery Figure 003-15 Connection of PWR CA-A Cables (2 of 2) NAP 200-003 Sheet 18/37 Installation of Main Equipment PIM7 PIM6 PIM5 PIM4 PIM3 PIM2 PIM1 PIM0PZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1PZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 PZ-PW86 BATT2 BATT1 TO BATTERY PWR CA-A TO BATTERY TO BATTERY PWR CA-A TO BATTERY TO BATTERY PWR CA-A TO BATTERY TO BATTERY PWR CA-A TO...
Page 58
ND-45492 (E) CHAPTER 3 Page 41 Revision 2.0 (12) When the system is a multiple-PIM configuration, mount the PN-BS00 Card in the BUS slot of PIM0. Also, mount the PN-BS01 Card in each BUS slot of PIM1 through PIM7. When the system is a single PIM configuration, neither PN-BS00 nor PN-BS01 is needed. Figure 003-16 Mounting of the BUS Cards NAP 200-003 Sheet 19/37 Installation of Main Equipment B S 0 1 B S 0 1 B S 0 1 B S 0 0 B S 0 1 B S 0 1 B S 0 1 B S 0 1 PIM3 PIM2 PIM1 PIM0PIM7 PIM6 PIM5 PIM4 BUS SLOT
Page 59
CHAPTER 3 ND-45492 (E) Pag e 4 2 Revision 2.0 (13) When the system is a multiple-PIM configuration, connect all the BUS Cards (PN-BS00/PN-BS01) to each other using BUS cables, as shown in Figure 003-17 and Figure 003-18. Figure 003-17 BUS Cable NAP 200-003 Sheet 20/37 Installation of Main Equipment 700mm (27.6 inch) 48-TW-0.7 CONN CA
Page 60
ND-45492 (E) CHAPTER 3 Page 43 Revision 2.0 Figure 003-18 Connection of the BUS Cables NAP 200-003 Sheet 21/37 Installation of Main Equipment PIM7 PIM6 PIM5 PIM4 PIM3 PIM2 PIM1 PIM0BS01 CN2 CN1 CN2 CN1 CN2 CN1 CN2 CN1BS01 CN2 CN1 CN2 CN1 CN2 CN1 CN2 CN1 48-TW-0.7 CONN CA BS01 BS01 BS00BS01 BS01 BS01