NEC Neax 2000 Ivs Installation Procedure Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs Installation Procedure Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 21
CHAPTER 2 ND-45492 (E) Pag e 4 Revision 2.0 Note :Refer to the Circuit Card Manual for details of circuit cards. Table 2-1 Description of Symbols in Trunking Diagram SYMBOL DESCRIPTION SYMBOL DESCRIPTION AM P Amplifier for External Speaker KEY External Key AP00 SMDR/Hotel Application Card LCD Line Circuit Card (for Single Line Telephone) AP01 OAI Interface Card LCI Line Circuit Card for Voice Mail Integra- tor AUC Analog Universal Circuit Card (Long Line Circuit, DID Trunk)MAT Maintenance...
Page 22
ND-45492 (E) CHAPTER 2 Page 5 Revision 2.0 2. SYSTEM CONFIGURATIONS The NEAX2000 IVS system provides four installation methods as follows: • Floor Standing Installation • Wall-Mounting Installation • 19-Inch Rack-Mounting Installation • Desk Top Installation This equipment can only be serviced by a qualified service person. Examples of system configurations for each installation method are shown in Figure 2-2 through 2-7. Figure 2-2 1-PIM Configuration for Floor Standing Installation RACK PARTS PIM...
Page 23
CHAPTER 2 ND-45492 (E) Pag e 6 Revision 2.0 Figure 2-3 2-PIM Configuration for Floor Standing Installation BASE (1) ONE FRAME CONFIGURATION RACK PARTS PIM1 PIM0 BASE BASE RACK PARTS PIM1 FRONT FRONT PIM0 (2) TWO FRAME CONFIGURATION
Page 24
ND-45492 (E) CHAPTER 2 Page 7 Revision 2.0 Figure 2-4 8-PIM Configuration for Floor Standing Installation PIM3 PIM2 PIM1 PIM0PIM7 PIM6 PIM5 PIM4 BASE FRONTRACK PARTS
Page 25
CHAPTER 2 ND-45492 (E) Pag e 8 Revision 2.0 Figure 2-5 1-PIM Configuration for Wall-Mounting Installation PIM RACK PARTS
Page 26
ND-45492 (E) CHAPTER 2 Page 9 Revision 2.0 Figure 2-6 1-PIM Configuration for 19-inch Rack-Mounting Installation PIM 19”BRACKET • • • •
Page 27
CHAPTER 2 ND-45492 (E) Pag e 1 0 Revision 2.0 Figure 2-7 1-PIM Configuration for Desk Top Installation PIM
Page 28
ND-45492 (E) CHAPTER 3 Page 11 Revision 2.0 CHAPTER 3 INSTALLATION PROCEDURE 1. PRECAUTIONS 1.1 GROUNDING REQUIREMENTS The system grounding must have a specific ground resistance and AC noise level, and is to be connected to a pre-determined terminal in the NEAX2000 IVS. Standard grounding requirements are as shown below: • Communication grounding : Less than 10 ohm • Protective ground for PIM: Less than 10 ohm Note:The AC ripple on these various grounds should be less than 0.5 Vp-p. The following...
Page 29
CHAPTER 3 ND-45492 (E) Pag e 1 2 Revision 2.0 1.2 STATIC ELECTRICITY PRECAUTIONS The installer must wear a grounded wrist strap to protect circuit cards from static electricity. Figure 3-1 Static Electricity Precautions (1 of 2) CARD FRONT PBX WRIST STRAP • WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD • WHEN HOLDING A CIRCUIT CARD FRAME GROUND SCREW NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS.
Page 30
ND-45492 (E) CHAPTER 3 Page 13 Revision 2.0 Figure 3-1 Static Electricity Precautions (2 of 2) WHEN CARRYING A CIRCUIT CARD AROUND, KEEP THE CARD IN A CONDUCTIVE POLYETHYLENE BAG. WEAR A WRIST STRAP AND PERFORM THE WORK ON A GROUNDED CONDUCTIVE WORK SURFACE. CIRCUIT CARD CIRCUIT CARDCONDUCTIVE POLYETHYLENE BAG • WHEN MAKING A SWITCH SETTING ON A CIRCUIT CARD • WHEN CARRYING A CIRCUIT CARD