Page 41
CHAPTER 3 ND-45492 (E) Pag e 2 4 Revision 2.0 (2) In a Multiple-PIM Configuration (a) When the system is a multiple-PIM configuration, connect the RACK PARTS to each other as shown in Figure 003-2. Figure 003-2 Connection of RACK PARTS NAP 200-003 Sheet 2/37 Installation of Main Equipment REARBASE RACK PARTS RACK PARTS
Page 42
ND-45492 (E) CHAPTER 3 Page 25 Revision 2.0 (b) For each PIM to be installed, install the 4 screws into the RACK PARTS on which the PIM(s) will be mounted as shown in Figure 003-3. Figure 003-3 Installation of Screws onto RACK PARTS NAP 200-003 Sheet 3/37 Installation of Main Equipment REARBASE
Page 43
CHAPTER 3 ND-45492 (E) Pag e 2 6 Revision 2.0 (3) Attaching the BASE to the floor. • Position the BASE over the holes drilled as per Figure 002-1. • Secure the BASE to the floor using anchor bolts. Figure 003-4 Securing of the BASE NAP 200-003 Sheet 4/37 Installation of Main Equipment FRONTBASE INSTALLATION HOLEANCHOR BOLT
Page 44
ND-45492 (E) CHAPTER 3 Page 27 Revision 2.0 (4) Secure the PIM to the RACK PARTS as shown in Figure 003-5 by tightening the 4 screws already mounted in the RACK PARTS. When the system is a multiple-PIM configuration, secure all PIMs and RACK PA RT S . Figure 003-5 Connection of the PIM and the RACK PARTS NAP 200-003 Sheet 5/37 Installation of Main Equipment REARBASE PIM Note:The Battery Module (BATM) and/or the MDF Module (MDFM) can be in- stalled in the same manner as the PIM.
Page 45
CHAPTER 3 ND-45492 (E) Pag e 2 8 Revision 2.0 (5) Mount the PIM on the BASE, and connect them together using 3 bolts (provided). Refer to Figure 003-6. Note:The PIM must be mounted over the 4 RACK PART screws previously installed in step 2(b). Figure 003-6 Mounting of the PIM NAP 200-003 Sheet 6/37 Installation of Main Equipment FRONT BASE PIM Note Note:The Battery Module (BATM) and/or the MDF Module (MDFM) can be installed in the same man- ner as the PIM.
Page 46
ND-45492 (E) CHAPTER 3 Page 29 Revision 2.0 (6) When the system is a multiple-PIM configuration, connect PIMs to each other with 3 bolts provided, as shown in Figure 003-7. Note:Each PIM must be installed over the 4 RACK PART screws previously installed in step 2(b). Figure 003-7 Connection of PIMs NAP 200-003 Sheet 7/37 Installation of Main Equipment PIM PIM FRONT
Page 47
CHAPTER 3 ND-45492 (E) Pag e 3 0 Revision 2.0 (7) Position the TOP COVER on the top PIM, and connect them together with 4 screws (provided). Figure 003-8 Mounting of the TOP COVER NAP 200-003 Sheet 8/37 Installation of Main Equipment FRONT PIM RACK PARTS TOP COVER
Page 48
ND-45492 (E) CHAPTER 3 Addendum-001 Page 31 JANUARY, 1999 Revision 2.1 (8) The cable connections on the PZ-PW86 card are shown in Figure 003-9. (a) PZ-PW86 (A) Figure 003-9 Cable Connection on the PZ-PW86 (1 of 3) NAP 200-003 Sheet 9/37 Installation of Main Equipment PZ-PW86(A) MJ MN ON BATTERY MODE SWITCH GND Note FG –27V PWR CNT CA-A PWR CA-A BATTERY CABLE/PWR CA-A TO PWR1 TO OTHER AC CORD-A TO AC MAINS INPUT TO POWER OUTPUT POWER OUTPUT TO PWR0A CONNECTOR TO PWR0B CONNECTOR CABLE (+5V, –27V,E)...
Page 49
CHAPTER 3 ND-45492 (E) Page 32 Addendum-001 Revision 2.1 JANUARY, 1999 (b) PZ-PW86 (C) Figure 003-9 Cable Connection on the PZ-PW86 (2 of 3) NAP 200-003 Sheet 10/37 Installation of Main Equipment PZ-PW86(C) MJ MN ON BATTERY MODE SWITCH GND Note 2 FG –27V PWR CNT CA-A PWR CA-A BATTERY CABLE/PWR CA-A TO PWR1 TO OTHER AC CORD-A TO AC MAINS INPUT TO POWER OUTPUT POWER OUTPUT TO PWR0A CONNECTOR TO PWR0B CONNECTOR CABLE (+5V, –27V,E) CABLE (CR, E) CONNECTOR PZ-PW86 TO AUXILIARY BATTERY CONNECTOR (BATT2)...
Page 50
ND-45492 (E) CHAPTER 3 Addendum-001 Page 33 JANUARY, 1999 Revision 2.1 (c) PZ-PW86 (D) Figure 003-9 Cable Connection on the PZ-PW86 (3 of 3) NAP 200-003 Sheet 11/37 Installation of Main Equipment PZ-PW86(D) MJ MN ON BATTERY MODE SWITCH GND Note 2 FG –27V PWR CNT CA-A TO P WR1 AC CORD-A TO AC MAINS INPUT TO POWER OUTPUT POWER OUTPUT TO PWR0A CONNECTOR TO PWR0B CONNECTOR CABLE (+5V, –27V,E) CABLE (CR, E) CONNECTOR TO AUXILIARY BATTERY CONNECTOR (BATT2) ON OFF 100/120V 240V EQUIPMENT GREEN WHITE BLACK...