CHAPTER 3 ND-45492 (E)
Pag e 8 4
Revision 2.0
3. Cable Running to the MDFM
(1) Connect the champ connector of each MDF cable to an LTC connector located on a PIM using the screws
provided, as shown in Figure 006-5.
(2) Pare the sheath of each MDF cable and secure the shield to the front bracket on the PIM using tie wraps,
as shown in Figure 006-5.
Figure 006-5  Cable Running to the MDFM
NAP 200-006
Sheet 6/7
Cable Running to the MDF
25 ~ 30 mm 
(1.0 ~ 1.2 inch) MDF CABLE
TIE WRAP SHIELDPIM
FRONT
TO...

Page 102

ND-45492 (E) CHAPTER 3
Page 85
Revision 2.0
(3) Connect the MDF cables to the MDF connectors in the MDFM, as shown in Figure 006-6.
Figure 006-6  Example of MDF Cable Connection to the MDFM
NAP 200-006
Sheet 7/7
Cable Running to the MDF
LTC0
LTC1
LTC2
LOCAL SIDE PBX SIDEMDF CABLE
MDF CONNECTOR
MDFM PIMBWB 

Page 103

CHAPTER 3 ND-45492 (E)
Pag e 8 6
Revision 2.0
1. Cable Connection to the MDF
(1) Connect the cables to the MDF referring to Figure 007-1 and Table 007-1.
Figure 007-1  Location of the Card Slots and the LTC Connectors
NAP 200-007
Sheet 1/56
Termination of Cables on the MDF
Table 007-1  LTC Connector Accommodation
LTC CONNECTOR CARD SLOT NUMBER REMARKS
LT C 0 LT 0 0  ~  LT 0 5
LT C 1 LT 0 6  ~  LT 0 9 ,  LT 1 0 / A P 0 ,  LT 1 1 / A P 1
LTC2 LT12/AP2 ~ LT15/AP5, AP6
LT09LT08LT07
LTC1LTC0LTC2
BWB
PIM
0 ~...

Page 104

ND-45492 (E) CHAPTER 3
Page 87
Revision 2.0
(2)Figure 007-2 shows the relationship between each Line Equipment Number (LEN) and each Card Slot
Number (LT Number).
(a) LEN 0000 ~ 0255
Figure 007-2  Location of each LEN (1 of 2)
NAP 200-007
Sheet 2/56
Termination of Cables on the MDF
0195
0194
0193
0192
(LT00)0199
0198
0197
0196
(LT01)0203
0202
0201
0200
(LT02)0211
0210
0209
0208
(LT04)0215
0214
0213
0212
(LT05)0219
0218
0217
0216
(LT06)0223
0222
0221
0220
(LT07)0227
0226
0225
0224
(LT08)0231
0230
0229...

Page 105

CHAPTER 3 ND-45492 (E)
Pag e 8 8
Revision 2.0
(b) LEN0256 ~ 0511
Figure 007-3  Location of each LEN (2 of 2)
NAP 200-007
Sheet 3/56
Termination of Cables on the MDF
0451
0450
0449
0448
(LT00)0455
0454
0453
0452
(LT01)0459
0458
0457
0456
(LT02)0467
0466
0465
0464
(LT04)0471
0470
0469
0468
(LT05)0475
0474
0473
0472
(LT06)0479
0478
0477
0476
(LT07)0483
0482
0481
0480
(LT08)0487
0486
0485
0484
(LT09)0491
0490
0489
0488
(LT10)0495
0494
0493
0492
(LT11)0499
0498
0497
0496
(LT12)0503
0502
0501
0500
(LT13)0507...

Page 106

ND-45492 (E) CHAPTER 3
Page 89
Revision 2.0
(3)Figure 007-4 shows the LTC Connector Pin Arrangement.
(a) PIM0 (LTC0 ~ LTC2)
Figure 007-4  LTC Connector Pin Arrangement (1 of 8)
NAP 200-007
Sheet 4/56
Termination of Cables on the MDF
LTC2
26 1 LEN0048
LT12/AP2 27 2 0049
28 3 0050
29 4 0051
30 5 0052
LT13/AP3 31 6 0053
32 7 0054
33 8 0055
34 9 0056
LT14/AP4 35 10 0057
36 11 0058
37 12 0059
38 13 0060
LT15/AP5 39 14 0061
40 15 0062
41 16 LEN0063
42 17
AP6
Note43 18
44 19
45 20
46 21
47 22
48 23
49 24
50 25...

Page 107

CHAPTER 3 ND-45492 (E)
Pag e 9 0
Revision 2.0
(b) PIM1 (LTC0 ~ LTC2)
Figure 007-5  LTC Connector Pin Arrangement (2 of 8)
NAP 200-007
Sheet 5/56
Termination of Cables on the MDF
LTC2
26 1 LEN0112
LT12/AP2 27 2 0113
28 3 0114
29 4 0115
30 5 0116
LT13/AP3 31 6 0117
32 7 0118
33 8 0119
34 9 0120
LT14/AP4 35 10 0121
36 11 0122
37 12 0123
38 13 0124
LT15/AP5 39 14 0125
40 15 0126
41 16 LEN0127
42 17
AP6
Note43 18
44 19
45 20
46 21
47 22
48 23
49 24
50 25
LTC0
26 1 LEN0064
LT00 27 2 0065
28 3 0066
29 4 0067
30...

Page 108

ND-45492 (E) CHAPTER 3
Page 91
Revision 2.0
(c) PIM2 (LTC0 ~ LTC2)
Figure 007-6  LTC Connector Pin Arrangement (3 of 8)
NAP 200-007
Sheet 6/56
Termination of Cables on the MDF
LTC2
26 1 LEN0176
LT12/AP2 27 2 0177
28 3 0178
29 4 0179
30 5 0180
LT13/AP3 31 6 0181
32 7 0182
33 8 0183
34 9 0184
LT14/AP4 35 10 0185
36 11 0186
37 12 0187
38 13 0188
LT15/AP5 39 14 0189
40 15 0190
41 16 LEN0191
42 17
AP6
Note43 18
44 19
45 20
46 21
47 22
48 23
49 24
50 25
LTC0
26 1 LEN0128
LT00 27 2 0129
28 3 0130
29 4 0131
30 5...

Page 109

CHAPTER 3 ND-45492 (E)
Pag e 9 2
Revision 2.0
(d) PIM3 (LTC0 ~ LTC2)
Figure 007-7  LTC Connector Pin Arrangment (4 of 8)
NAP 200-007
Sheet 7/56
Termination of Cables on the MDF
LTC2
26 1 LEN0240
LT12/AP2 27 2 0241
28 3 0242
29 4 0243
30 5 0244
LT13/AP3 31 6 0245
32 7 0246
33 8 0247
34 9 0248
LT14/AP4 35 10 0249
36 11 0250
37 12 0251
38 13 0252
LT15/AP5 39 14 0253
40 15 0254
41 16 LEN0255
42 17
AP6
Note43 18
44 19
45 20
46 21
47 22
48 23
49 24
50 25
LTC0
26 1 LEN0192
LT00 27 2 0193
28 3 0194
29 4 0195
30...

Page 110

ND-45492 (E) CHAPTER 3
Page 93
Revision 2.0
(e) PIM4 (LTC0 ~ LTC2)
Figure 007-8  LTC Connector Pin Arrangement (5 of 8)
NAP 200-007
Sheet 8/56
Termination of Cables on the MDF
LTC2
26 1 LEN0304
LT12/AP2 27 2 0305
28 3 0306
29 4 0307
30 5 0308
LT13/AP3 31 6 0309
32 7 0310
33 8 0311
34 9 0312
LT14/AP4 35 10 0313
36 11 0314
37 12 0315
38 13 0316
LT15/AP5 39 14 0317
40 15 0318
41 16 LEN0319
42 17
AP6
Note43 18
44 19
45 20
46 21
47 22
48 23
49 24
50 25
LTC0
26 1 LEN0256
LT00 27 2 0257
28 3 0258
29 4 0259
30 5...
Start reading NEC Neax 2000 Ivs Installation Procedure Manual

Related Manuals for NEC Neax 2000 Ivs Installation Procedure Manual

All NEC manuals