Page 131
CHAPTER 3 ND-45492 (E) Pag e 1 14 Revision 2.0 Figure 007-23 MDF Cross Connection for an SN610 ATTCON (3 of 3) NAP 200-007 Sheet 29/56 Termination of Cables on the MDF 1 LTC CONNECTOR2 CN1 CONNECTOR 1 2 3 4TA0 TB0 TA1 TB126 27 28 29RA0 RB0 RA1 RB1 (P)26 27 28 29RA0 RB0 RA1 RB11 2 3 4TA0 TB0 TA1 TB1 LTC0 (J)LEN0000 LEN0001LEN0003 RB3 TB3 RA3 TA3 LEN0002 RB2 TB2 RA2 TA2 CN1
Page 132
ND-45492 (E) CHAPTER 3 Addendum-001 Page 115 JANUARY, 1999 Revision 2.1 (7) SN716 DESKCON (a) When using PN-4DLCA/4DLCD/4DLCM/4DLCQ Figure 007-24 MDF Cross Connection for a SN716 DESKCON (1 of 2) NAP 200-007 Sheet 30/56 Termination of Cables on the MDF MODULAR TERMINAL 6 5 4 3 2 1Note Note Note:When power is supplied by the AC-DC ADAPTER, this connection is not required. TO SN716 DESKCON 29T7294 R7428 T6283 R6327 T12726 T026 2 1 MDF R01 R12 LEN0000 (No. 0) PIM0 P PN-4DLC LT00LTC0 J LEN0001 (No. 1)...
Page 133
CHAPTER 3 ND-45492 (E) Page 116 Addendum-001 Revision 2.1 JANUARY, 1999 (b) When using PN-2DLCB/2DLCN Figure 007-24 MDF Cross Connection for a SN716 DESKCON (2 of 2) NAP 200-007 Sheet 31/56 Termination of Cables on the MDF MODULAR TERMINAL 6 5 4 3 2 1Note Note Note:When power is supplied by the AC-DC ADAPTER, this connection is not required. TO SN716 DESKCON 29294 428 283 327 T12726 T026 2 1 MDF R01 R12 LEN0000 (No. 0) PIM0 PN-2DLC LT00 LEN0001 (No. 1) 1R029T0 2R128T1 327 426 (P) 26 T0 1 R0 27 T1 2 R1...
Page 134
ND-45492 (E) CHAPTER 3 Page 117 Revision 2.0 (8) Day/Night Mode Change by External Key Figure 007-25 MDF Cross Connection for Day/Night Mode Change by External Key NAP 200-007 Sheet 32/56 Termination of Cables on the MDF 29K7294 K6428 K5283 K4327 K32726 K126 2 1 1 K026K1 2K227K3 3K428K5 4K629K7 (P) 26K11K0 27K32K2 28K53K4 29K74K6LEN0000 LEN0002 LTC0 (J)MDF K01 K22LEN0000 PIM0 P PN-DK00 LT00LTC0 J LEN0002 K7 K6 K5 K4 K3 K1 K2 K0 TO KEYS
Page 135
CHAPTER 3 ND-45492 (E) Pag e 1 18 Revision 2.0 (9) External TAS Indicator (a) Outline of the Connection Figure 007-26 Outline of the External TAS Indicator Connection Note: The DK00 card will drive relays; there are no relays provided on the PN-DK00 card. NAP 200-007 Sheet 33/56 Termination of Cables on the MDF MD F PBX PN-DK00 Card PZ-PW86 Card G G IND TAS Indicator with Battery MD F PBX PN-DK00 Card IND TAS Indicator with Battery (Ground Start)
Page 136
ND-45492 (E) CHAPTER 3 Page 119 Revision 2.0 (b) MDF Cross Connection • When using a TAS Indicator with a Battery Figure 007-27 MDF Cross Connection for a TAS Indicator with a Battery NAP 200-007 Sheet 34/56 Termination of Cables on the MDF 29K7294 K6428 K5283 K4327 K32726 K126 2 1 1 K026K1 2 K227K3 3 K428K5 4 K629K7 (P) 26 K1 1 K0 27K32K2 28K53K4 29K74K6LEN0000 LEN0002 LTC0 (J)MDF K01 K22LEN0000 PIM0 P PN-DK00 LT 0 0LT C 0 J LEN0002 TAS INDICATOR WITH BATTERY IND PZ-PW86 -27V G K0
Page 137
CHAPTER 3 ND-45492 (E) Pag e 1 20 Revision 2.0 • When using a TAS Indicator with a Battery (Ground Start) Figure 007-28 MDF Cross Connection for a TAS Indicator with a Battery (Ground Start) NAP 200-007 Sheet 35/56 Termination of Cables on the MDF 29294 428 283 327 2726 26 2 1 1K026K1 2 K227K3 3 K428K5 4 K629K7 (P) 26K11K0 27K32K2 28K53K4 29K74K6LEN0000 LEN0002 LT C 0 ( J )MDF 1 2 P PN-DK00LT C 0J TAS INDICATOR WITH BATTERY (GROUND START) IND K7 K6 K5 K4 K3 K1 K0 K2LEN0000 LT 0 0 LEN0002 PIM0 K0
Page 138
ND-45492 (E) CHAPTER 3 Page 121 Revision 2.0 (10) Paging Equipment The cross connection for a customer owned paging equipment is shown in Figure 007-29 through Figure 007-31, as an example. Requirement for the Paging Equipment • Input Impedance : 600 ohm • Control Method : Start - Ground Start Note : Stop - Ground Off (Open) Note:The current capacity of the relay driver (PN-DK00 card) is 0.125 A. (a) Outline of the Connection Figure 007-29 Outline of the Paging Equipment Connection NAP 200-007 Sheet...
Page 139
CHAPTER 3 ND-45492 (E) Pag e 1 22 Revision 2.0 (b) MDF Cross Connection Figure 007-30 MDF Cross Connection for a Paging Equipment (1 of 2) NAP 200-007 Sheet 37/56 Termination of Cables on the MDF 29K7294 K6428 K5283 K4327 K32726 K126 2 1K01 K22LEN0000 LEN0002 PIM0 P PN-DK00 LT 0 0LT C 0 J 33338 832 327 731 3130 30 6 55 6 PN-4COT PZ-PW86 MDF G Ring TipCONTROL CIRCUIT SPEECH PAT H CIRCUIT PAGING EQUIPMENT SPEAKER G LT 0 1 T3 R3 T2 R2 T1 T0 R0 R1 LEN0004 (No. 0) LEN0005 (No. 1) LEN0006 (No. 2)...
Page 140
ND-45492 (E) CHAPTER 3 Page 123 Revision 2.0 Figure 007-31 MDF Cross Connection for Paging Equipment (2 of 2) NAP 200-007 Sheet 38/56 Termination of Cables on the MDF 26 1 K0 27 2 28 3 29 4 30 T0 5 R0 31 6 32 7 33 8 LTC0 (J) 1K026 227 328 429 5R030T0 631 732 833 (P) LEN0004 LEN0005 LEN0006 LEN0007 LEN0000 LEN0002