Home > NEC > Communications System > NEC Neax 2000 Ivs Installation Procedure Manual

NEC Neax 2000 Ivs Installation Procedure Manual

Here you can view all the pages of manual NEC Neax 2000 Ivs Installation Procedure Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 111

CHAPTER 3 ND-45492 (E)
Pag e 9 4
Revision 2.0
(f) PIM5 (LTC0 ~ LTC2)
Figure 007-9  LTC Connector Pin Arrangement (6 of 8)
NAP 200-007
Sheet 9/56
Termination of Cables on the MDF
LTC2
26 1 LEN0368
LT12/AP2 27 2 0369
28 3 0370
29 4 0371
30 5 0372
LT13/AP3 31 6 0373
32 7 0374
33 8 0375
34 9 0376
LT14/AP4 35 10 0377
36 11 0378
37 12 0379
38 13 0380
LT15/AP5 39 14 0381
40 15 0382
41 16 LEN0383
42 17
AP6
Note43 18
44 19
45 20
46 21
47 22
48 23
49 24
50 25
LTC0
26 1 LEN0320
LT00 27 2 0321
28 3 0322
29 4 0323
30...

Page 112

ND-45492 (E) CHAPTER 3
Page 95
Revision 2.0
(g) PIM6 (LTC0 ~ LTC2)
Figure 007-10  LTC Connector Pin Arrangement  (7 of 8)
NAP 200-007
Sheet 10/56
Termination of Cables on the MDF
LTC2
26 1 LEN0432
LT12/AP2 27 2 0433
28 3 0434
29 4 0435
30 5 0436
LT13/AP3 31 6 0437
32 7 0438
33 8 0439
34 9 0440
LT14/AP4 35 10 0441
36 11 0442
37 12 0443
38 13 0444
LT15/AP5 39 14 0445
40 15 0446
41 16 LEN0447
42 17
AP6
Note43 18
44 19
45 20
46 21
47 22
48 23
49 24
50 25
LTC0
26 1 LEN0384
LT00 27 2 0385
28 3 0386
29 4 0387...

Page 113

CHAPTER 3 ND-45492 (E)
Pag e 9 6
Revision 2.0
(h) PIM7 (LTC0 ~ LTC2)
Figure 007-11  LTC Connector Pin Arrangement (8 of 8)
NAP 200-007
Sheet 11/56
Termination of Cables on the MDF
LTC2
26 1 LEN0496
LT12/AP2 27 2 0497
28 3 0498
29 4 0499
30 5 0500
LT13/AP3 31 6 0501
32 7 0502
33 8 0503
34 9 0504
LT14/AP4 35 10 0505
36 11 0506
37 12 0507
38 13 0508
LT15/AP5 39 14 0509
40 15 0510
41 16 LEN0511
42 17
AP6
Note43 18
44 19
45 20
46 21
47 22
48 23
49 24
50 25
LTC0
26 1 LEN0448
LT00 27 2 0449
28 3 0450
29 4 0451...

Page 114

ND-45492 (E) CHAPTER 3
Page 97
Revision 2.0
2. MDF Cross Connections
Cross connections on the MDF for LTC0 through LTC2 are shown in Table 007-2 through Table 007-5.
NAP 200-007
Sheet 12/56
Termination of Cables on the MDF
Table 007-2  LTC0-LTC2 MDF Cross Connection Information (1 of 4)
PINRUNNING
CABLESTATION
CABLESLOTSTYPE OF INTERFACE
CO
(4COT)CO
(2COT)2-WIRE 
E&M TIE 
LINE 
(2ODT)4-WIRE 
E&M TIE 
LINE 
(2ODT)DID
(AUC)SLT
 (4LC)SLT
(AUC)
26 WH-BL GN
1T0 T0 T0 TxT0 T0 T0 T0
1 BL-WH RD R0 R0 R0 TxR0 R0...

Page 115

CHAPTER 3 ND-45492 (E)
Pag e 9 8
Revision 2.0
* Major and minor alarm connections for external indications are located on LTC0 of PIM0, only.
NAP 200-007
Sheet 13/56
Termination of Cables on the MDF
Table 007-3  LTC0-LTC2 MDF Cross Connection Information (2 of 4)
PINRUNNING
CABLESTATION
CABLESLOTSTYPE OF INTERFACE
COT
(4COT)COT
(2COT)2-WIRE 
E&M TIE 
LINE 
(2ODT)4-WIRE 
E&M TIE 
LINE 
(2ODT)DID
(AUC)SLT
 (4LC)SLT
(AUC)
38 BK-GN GN
4T0 T0 T0 TxT0 T0 T0 T0
13 GN-BK RD R0 R0 R0 TxR0 R0 R0 R0
39 BK-BR BK T1...

Page 116

ND-45492 (E) CHAPTER 3
Page 99
Revision 2.0
Note 1:2 wire type for Multiline Terminal/DSS Consol/SN716 DESKCON.
Note 2:4 wire type for Multiline Terminal/SN610 ATTCON.
NAP 200-007
Sheet 14/56
Termination of Cables on the MDF
Table 007-4  LTC0-LTC2 MDF Cross Connection Information (3 of 4)
PINRU NN ING
CABLESTATION
CABLESLOTSTYPE OF INTERFACE
D
term/
SN716 
DESKCON 
(4DLC) 
Note 1Dterm/
SN716 
DESKCON 
(2DLC) 
Note 1Dterm 
(4DLC) 
Note 2SN610 
AT T C O N  
(2DLC) 
Note 2EXT. KEY/
EXT.
RELAY
(DK00)EXT.
PAG...

Page 117

CHAPTER 3 ND-45492 (E)
Pag e 1 00
Revision 2.0
* Major and minor alarm connections for external indications are located on LTC0 of PIM0, only.
Note 1:2 wire type for Multiline Terminal/DSS Consol/SN716 DESKCON.
Note 2:4 wire type for Multiline Terminal/SN610 ATTCON.
NAP 200-007
Sheet 15/56
Termination of Cables on the MDF
Table 007-5  LTC0-LTC2 MDF Cross Connection Information (4 of 4)
PINRUNNING
CABLESTATION
CABLESLOTSTYPE OF INTERFACE
D
term/
SN716 
DESKCON 
(4DLC) 
Note 1Dterm/
SN716 
DESKCON 
(2DLC)...

Page 118

ND-45492 (E) CHAPTER 3
Page 101
Revision 2.0
(1) C.O. Trunk
(a) 4 Line C.O. Trunk (PN-4COT)
Figure 007-12  MDF Cross Connection for a 4 Line C.O. Trunk Card (PN-4COT)
NAP 200-007
Sheet 16/56
Termination of Cables on the MDF
29T3294
R3428
T2283
R2327
T12726
T026
2
1
1R0 26T0
2R127T1
3
R228T2
4
R329T3
(P)
26 T0 1 R0
27T12R1
28
T23R2
29
T34R3
LEN0000
LEN0001
LEN0002
LEN0003
LTC0 (J)MDF
R01
R12
LEN0000      (No. 0)
LEN0001      (No. 1)
LEN0002      (No. 2)
LEN0003      (No. 3)
TO C.O. L INE
TO C.O. L INE
TO...

Page 119

CHAPTER 3 ND-45492 (E)
Pag e 1 02
Revision 2.0
(2) Tie Line Trunk
(a) 4W E&M (PN-2ODT)
Figure 007-13  MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT) (1 of 2)
NAP 200-007
Sheet 17/56
Termination of Cables on the MDF
Note 1:Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT card.
Note 2:When connecting the E and M, make the installation cable by using the connector attached with the 
PN-2ODT card.
PIM0
08 
07 
06 
05 
04 
03 
02 
01M1 
E1 
M0 
E0
LEN0001...

Page 120

ND-45492 (E) CHAPTER 3
Page 103
Revision 2.0
Figure 007-14  MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT) (2 of 2)
NAP 200-007
Sheet 18/56
Termination of Cables on the MDF
M1
E1
M0
E0LEN0001
LEN0000
CN1
1 LTC CONNECTOR2 CN1 CONNECTOR
(FRONT CONNECTOR)
LEN0000
LEN00011 TxR0 26 TxT0
2 RcvR0 27 RcvT0
3 TxR1 28 TxT1
4 RcvR1 29 RcvT1
(P)
26 TxT0 1 TxR0
27 RcvT0 2 RcvR0
28 TxT1 3 TxR1
29 RcvT1 4 RcvR1
LTC0 (J) 
Start reading NEC Neax 2000 Ivs Installation Procedure Manual

Related Manuals for NEC Neax 2000 Ivs Installation Procedure Manual

All NEC manuals