NEC Neax 2000 Ivs Installation Procedure Manual
Here you can view all the pages of manual NEC Neax 2000 Ivs Installation Procedure Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 111
CHAPTER 3 ND-45492 (E) Pag e 9 4 Revision 2.0 (f) PIM5 (LTC0 ~ LTC2) Figure 007-9 LTC Connector Pin Arrangement (6 of 8) NAP 200-007 Sheet 9/56 Termination of Cables on the MDF LTC2 26 1 LEN0368 LT12/AP2 27 2 0369 28 3 0370 29 4 0371 30 5 0372 LT13/AP3 31 6 0373 32 7 0374 33 8 0375 34 9 0376 LT14/AP4 35 10 0377 36 11 0378 37 12 0379 38 13 0380 LT15/AP5 39 14 0381 40 15 0382 41 16 LEN0383 42 17 AP6 Note43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25 LTC0 26 1 LEN0320 LT00 27 2 0321 28 3 0322 29 4 0323 30...
Page 112
ND-45492 (E) CHAPTER 3 Page 95 Revision 2.0 (g) PIM6 (LTC0 ~ LTC2) Figure 007-10 LTC Connector Pin Arrangement (7 of 8) NAP 200-007 Sheet 10/56 Termination of Cables on the MDF LTC2 26 1 LEN0432 LT12/AP2 27 2 0433 28 3 0434 29 4 0435 30 5 0436 LT13/AP3 31 6 0437 32 7 0438 33 8 0439 34 9 0440 LT14/AP4 35 10 0441 36 11 0442 37 12 0443 38 13 0444 LT15/AP5 39 14 0445 40 15 0446 41 16 LEN0447 42 17 AP6 Note43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25 LTC0 26 1 LEN0384 LT00 27 2 0385 28 3 0386 29 4 0387...
Page 113
CHAPTER 3 ND-45492 (E) Pag e 9 6 Revision 2.0 (h) PIM7 (LTC0 ~ LTC2) Figure 007-11 LTC Connector Pin Arrangement (8 of 8) NAP 200-007 Sheet 11/56 Termination of Cables on the MDF LTC2 26 1 LEN0496 LT12/AP2 27 2 0497 28 3 0498 29 4 0499 30 5 0500 LT13/AP3 31 6 0501 32 7 0502 33 8 0503 34 9 0504 LT14/AP4 35 10 0505 36 11 0506 37 12 0507 38 13 0508 LT15/AP5 39 14 0509 40 15 0510 41 16 LEN0511 42 17 AP6 Note43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25 LTC0 26 1 LEN0448 LT00 27 2 0449 28 3 0450 29 4 0451...
Page 114
ND-45492 (E) CHAPTER 3 Page 97 Revision 2.0 2. MDF Cross Connections Cross connections on the MDF for LTC0 through LTC2 are shown in Table 007-2 through Table 007-5. NAP 200-007 Sheet 12/56 Termination of Cables on the MDF Table 007-2 LTC0-LTC2 MDF Cross Connection Information (1 of 4) PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE CO (4COT)CO (2COT)2-WIRE E&M TIE LINE (2ODT)4-WIRE E&M TIE LINE (2ODT)DID (AUC)SLT (4LC)SLT (AUC) 26 WH-BL GN 1T0 T0 T0 TxT0 T0 T0 T0 1 BL-WH RD R0 R0 R0 TxR0 R0...
Page 115
CHAPTER 3 ND-45492 (E) Pag e 9 8 Revision 2.0 * Major and minor alarm connections for external indications are located on LTC0 of PIM0, only. NAP 200-007 Sheet 13/56 Termination of Cables on the MDF Table 007-3 LTC0-LTC2 MDF Cross Connection Information (2 of 4) PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE COT (4COT)COT (2COT)2-WIRE E&M TIE LINE (2ODT)4-WIRE E&M TIE LINE (2ODT)DID (AUC)SLT (4LC)SLT (AUC) 38 BK-GN GN 4T0 T0 T0 TxT0 T0 T0 T0 13 GN-BK RD R0 R0 R0 TxR0 R0 R0 R0 39 BK-BR BK T1...
Page 116
ND-45492 (E) CHAPTER 3 Page 99 Revision 2.0 Note 1:2 wire type for Multiline Terminal/DSS Consol/SN716 DESKCON. Note 2:4 wire type for Multiline Terminal/SN610 ATTCON. NAP 200-007 Sheet 14/56 Termination of Cables on the MDF Table 007-4 LTC0-LTC2 MDF Cross Connection Information (3 of 4) PINRU NN ING CABLESTATION CABLESLOTSTYPE OF INTERFACE D term/ SN716 DESKCON (4DLC) Note 1Dterm/ SN716 DESKCON (2DLC) Note 1Dterm (4DLC) Note 2SN610 AT T C O N (2DLC) Note 2EXT. KEY/ EXT. RELAY (DK00)EXT. PAG...
Page 117
CHAPTER 3 ND-45492 (E) Pag e 1 00 Revision 2.0 * Major and minor alarm connections for external indications are located on LTC0 of PIM0, only. Note 1:2 wire type for Multiline Terminal/DSS Consol/SN716 DESKCON. Note 2:4 wire type for Multiline Terminal/SN610 ATTCON. NAP 200-007 Sheet 15/56 Termination of Cables on the MDF Table 007-5 LTC0-LTC2 MDF Cross Connection Information (4 of 4) PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE D term/ SN716 DESKCON (4DLC) Note 1Dterm/ SN716 DESKCON (2DLC)...
Page 118
ND-45492 (E) CHAPTER 3 Page 101 Revision 2.0 (1) C.O. Trunk (a) 4 Line C.O. Trunk (PN-4COT) Figure 007-12 MDF Cross Connection for a 4 Line C.O. Trunk Card (PN-4COT) NAP 200-007 Sheet 16/56 Termination of Cables on the MDF 29T3294 R3428 T2283 R2327 T12726 T026 2 1 1R0 26T0 2R127T1 3 R228T2 4 R329T3 (P) 26 T0 1 R0 27T12R1 28 T23R2 29 T34R3 LEN0000 LEN0001 LEN0002 LEN0003 LTC0 (J)MDF R01 R12 LEN0000 (No. 0) LEN0001 (No. 1) LEN0002 (No. 2) LEN0003 (No. 3) TO C.O. L INE TO C.O. L INE TO...
Page 119
CHAPTER 3 ND-45492 (E) Pag e 1 02 Revision 2.0 (2) Tie Line Trunk (a) 4W E&M (PN-2ODT) Figure 007-13 MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT) (1 of 2) NAP 200-007 Sheet 17/56 Termination of Cables on the MDF Note 1:Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT card. Note 2:When connecting the E and M, make the installation cable by using the connector attached with the PN-2ODT card. PIM0 08 07 06 05 04 03 02 01M1 E1 M0 E0 LEN0001...
Page 120
ND-45492 (E) CHAPTER 3 Page 103 Revision 2.0 Figure 007-14 MDF Cross Connection for a 4W E&M Trunk Card (PN-2ODT) (2 of 2) NAP 200-007 Sheet 18/56 Termination of Cables on the MDF M1 E1 M0 E0LEN0001 LEN0000 CN1 1 LTC CONNECTOR2 CN1 CONNECTOR (FRONT CONNECTOR) LEN0000 LEN00011 TxR0 26 TxT0 2 RcvR0 27 RcvT0 3 TxR1 28 TxT1 4 RcvR1 29 RcvT1 (P) 26 TxT0 1 TxR0 27 RcvT0 2 RcvR0 28 TxT1 3 TxR1 29 RcvT1 4 RcvR1 LTC0 (J)