Page 181
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 143 Distinctive Ringing 11. The lamp indication patterns are as follows: • Incoming internal calls Red, 120-ipm flashing • Incoming external calls Green or Red, 120-ipm flashing The lamp color for incoming external calls can be selected to be green or red. 12. The lamp color for incoming external calls can be designated on a per-trunk-route basis. 13. The distinctive lamp indication is valid for Direct Inward...
Page 182
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 144NDA-24158, Issue 2 Do Not Disturb Do Not Disturb General Description This feature restricts incoming calls to a station and can be set by an individual station or from the Attendant Console. Placing a station in Do Not Disturb (DND) does not prevent a station from originating a voice or data call or from receiving a data call. This feature also allows a station to ensure privacy from telephone interrup- tions while on an outgoing...
Page 183
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 145 Do Not Disturb 2. Depress the DD key and the associated LED flashes. 3. Depress the START key. The DD LED lights steady and service set tone is received. 4. Depress the RELEASE key. n To cancel an individual station in DND 1. Dial the desired station number. 2. Depress the DD key and the associated LED flashes. 3. Depress the RESET key and the DD LED goes out. 4. Depress the RELEASE key. n To set a group of...
Page 184
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 146NDA-24158, Issue 2 Do Not Disturb Do Not Disturb-Data Line 10. Only the Attendant has the ability to place a group of stations in Do Not Disturb. There is only one group available and the stations within the group are programmed in system data. There is no limitation on the number of stations in the group. 11. A station included in a DND group, retains the ability to place their particular station in DND. 12. When the Attendant places...
Page 185
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 147 Do Not Disturb Do Not Disturb-Hotel/Motel Do Not Disturb-Hotel/Motel General Description This feature allows the Attendant Console(s), Hotel/Motel Front Desk Instrument(s), guest stations or Property Management System (PMS) terminal(s) to place individual stations into Do Not Disturb. Calls can be placed from stations set in DND. Station Application All stations. Operating Procedure From the Hotel/Motel Front Desk...
Page 186
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 148NDA-24158, Issue 2 Do Not Disturb Do Not Disturb-System 3. Receive service set tone and restore the handset. n To cancel Do Not Disturb 1. Go off-hook and receive dial tone. 2. Dial the Do Not Disturb cancellation code. 3. Receive service set tone and restore the handset. Service Conditions 1. Automatic Wake Up and Timed Reminder will override Do Not Disturb. 2. A station in Do Not Disturb can be called from the Attendant Console or...
Page 187
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 149 Do Not Disturb Do Not Disturb-System 3. Depress the SET key. 4. Depress the RLS key. To cancel Do Not Disturb - System from the Hotel/Motel Front Desk Instrument 1. Depress the DD key. 2. Depress the GROUP key. 3. Depress the RESET key. 4. Depress the RLS key. Service Conditions 1. Stations are assigned to the Do Not Disturb (DND) Group in Class of Service. 2. Calls to extensions whose stations are in Do Not Disturb...
Page 188
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 150NDA-24158, Issue 2 Elapsed Call Timer Elapsed Call Timer General Description This feature provides a display of the elapsed time while a Multiline Terminal with LCD is connected to any trunk. Station Application All Multiline Terminals with LCD. Operating Procedure No manual operation is required. Service Conditions 1. The elapsed time is displayed in the seven upper left-hand positions of the LCD display. 2. The elapsed time can...
Page 189
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Revision 2.3 Addendum-003 Page 150-1October, 1996 Enhanced 911 Enhanced 911 General Description This feature allows the PBX to transmit a callers’ emergency service identification information to an Enhanced 911 Emergency system. Station Application All stations and Attendant Consoles. Operating Procedure 1. Lift the handset and receive a dial tone. 2. Dial the trunk access code and telephone number (e.g. 911). 3. The system...
Page 190
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 151 Executive Calling Executive Calling General Description This feature allows a station to be assigned a VIP class. This provides special ringing to a called station when that station is idle, and automatic sending of three tone bursts to a called station when that station is busy, pro- vided the call was originated from a station assigned as VIP class. Station Application All stations. Operating Procedure To initiate...