Home > NEC > Communications System > NEC Neax 2000 Ivs Business/Hotel/Data Features And Specifications

NEC Neax 2000 Ivs Business/Hotel/Data Features And Specifications

Here you can view all the pages of manual NEC Neax 2000 Ivs Business/Hotel/Data Features And Specifications. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 141

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 104NDA-24158, Issue 2
Check In / Check Out
Check In / Check Out
General Description
When this feature is activated, the following operations occur:
•Check In
Room Cutoff is cleared.
•Check Out
Room Status printout is supplied.
Do Not Disturb is reset.
Room Cutoff is set.
Message Waiting is reset.
Automatic Wake Up is cleared.
Station Application
Multiline Terminals with LCD assigned as Hotel/Motel Front Desk Instruments.
Operating...

Page 142

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 105
Class of Service
Class  of  Service
General Description
This feature permits all stations to be assigned a Class of Service in accordance with the degree of system use
desired.  The Class of Service is used to assign restrictions for trunk access and feature access.
Station Application
All stations.
Operating Procedure
Normal operating procedures apply.  Restrictions are automatically applied by the system based on...

Page 143

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 106NDA-24158, Issue 2
Class of Service
Speed Calling - System
Speed Calling - Station
External Paging
Automatic Wake Up/Timed Reminder - self
Automatic  Wake Up/Timed Reminder - for others
Call Pickup Direct 
Camp-On (Transfer)
Camp-On (Call Waiting) - Originate/Receive
Do Not Disturb from Station/Return Schedule Message Display
Priority Call 
Trunk to Trunk Transfer
Message Wait- Set/Reset
Timed Queue
Account Code Entry
Authorization...

Page 144

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 107
Class of Service
c) Camp-On (Call Waiting)
d) Hunting
5. Separately from the above, each station can be assigned to have the following options:
6. Authorization Codes can be used to temporarily change the trunk route restriction class (incoming, outgo-
ing, and code restrictions) and the feature service class (A, B, C) when a station is used.  Refer to the Au-
thorization Code feature.
7. Two assignments, one for day...

Page 145

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 108NDA-24158, Issue 2
Code Restriction
Code  Restriction
General Description
This feature allows the NEAX2000 IVS to be programmed to restrict outgoing calls according to specific area
and/or Central Office codes.  This restriction is controlled on the basis of a three digit area code or six digit area
and office code numbering plan.
Station Application
All stations.
Operating Procedure
No manual operation is required.
Service Conditions...

Page 146

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 109
Conference (Three/Four Party)
Conference (Three/Four Party)
General Description
This feature provides a station user the ability to add-on another party (trunk or station) to a call already in
progress.  Single Line Telephone users can add up to one additional party and Multiline Terminal users can add
up to two additional parties.
Station Application
All stations.
Operating Procedure
To add a third party
n  From a...

Page 147

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 110NDA-24158, Issue 2
Conference (Three/Four Party)
5. Multiline Terminals may allow other Multiline Terminals with the same line button appearance to enter the
conversation (and therefore establish a Conference) by using the Privacy feature.  Refer to the Privacy Fea-
tures and Specifications for more information.
6. Once the second party answers, and prior to depressing the CNF key, Multiline Terminals may use the TRF
or ANS key to...

Page 148

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Revision 2.1 Addendum-001
Page 111February, 1996
Conference (Six/Ten Party)
Conference (Six/Ten Party)
General Description
This feature permits a station user or Attendant (conference leader) to establish a Conference among as many
as six or ten parties (including the Conference leader).
Station Application
All stations and Attendant Consoles
Operating Procedure
Using the access code
n  To make a Conference Call
1. The Conference...

Page 149

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 112Addendum-001 NDA-24158, Revision 2.1
February, 1996
Conference (Six/Ten Party)
3. After the party answers, press the HOLD key.
4. Call all desired parties (station or C.O./tie line) sequentially, using other line keys, and placing each on hold
after the party answers.
5. After holding the last party, press the Conference feature key.  The line key associated with the last party
lights green.  The last party is connected to the CFT...

Page 150

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Revision 2.1 Addendum-001
Page 112-1February, 1996
Conference (Six/Ten Party)
Service Conditions
1. Access codes A, B and C must be different numbers.  A is used to reserve the Conference board.  B is used
to add Conference member.  C is used to force release a member from the Conference.
2. Up to four CFT trunks (PN-CFTA) can be accommodated in the system.
3. The maximum number of participants which can be connected in a Conference...
Start reading NEC Neax 2000 Ivs Business/Hotel/Data Features And Specifications

Related Manuals for NEC Neax 2000 Ivs Business/Hotel/Data Features And Specifications

All NEC manuals