Page 141
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 104NDA-24158, Issue 2 Check In / Check Out Check In / Check Out General Description When this feature is activated, the following operations occur: •Check In Room Cutoff is cleared. •Check Out Room Status printout is supplied. Do Not Disturb is reset. Room Cutoff is set. Message Waiting is reset. Automatic Wake Up is cleared. Station Application Multiline Terminals with LCD assigned as Hotel/Motel Front Desk Instruments. Operating...
Page 142
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 105 Class of Service Class of Service General Description This feature permits all stations to be assigned a Class of Service in accordance with the degree of system use desired. The Class of Service is used to assign restrictions for trunk access and feature access. Station Application All stations. Operating Procedure Normal operating procedures apply. Restrictions are automatically applied by the system based on...
Page 143
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 106NDA-24158, Issue 2 Class of Service Speed Calling - System Speed Calling - Station External Paging Automatic Wake Up/Timed Reminder - self Automatic Wake Up/Timed Reminder - for others Call Pickup Direct Camp-On (Transfer) Camp-On (Call Waiting) - Originate/Receive Do Not Disturb from Station/Return Schedule Message Display Priority Call Trunk to Trunk Transfer Message Wait- Set/Reset Timed Queue Account Code Entry Authorization...
Page 144
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 107 Class of Service c) Camp-On (Call Waiting) d) Hunting 5. Separately from the above, each station can be assigned to have the following options: 6. Authorization Codes can be used to temporarily change the trunk route restriction class (incoming, outgo- ing, and code restrictions) and the feature service class (A, B, C) when a station is used. Refer to the Au- thorization Code feature. 7. Two assignments, one for day...
Page 145
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 108NDA-24158, Issue 2 Code Restriction Code Restriction General Description This feature allows the NEAX2000 IVS to be programmed to restrict outgoing calls according to specific area and/or Central Office codes. This restriction is controlled on the basis of a three digit area code or six digit area and office code numbering plan. Station Application All stations. Operating Procedure No manual operation is required. Service Conditions...
Page 146
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 109 Conference (Three/Four Party) Conference (Three/Four Party) General Description This feature provides a station user the ability to add-on another party (trunk or station) to a call already in progress. Single Line Telephone users can add up to one additional party and Multiline Terminal users can add up to two additional parties. Station Application All stations. Operating Procedure To add a third party n From a...
Page 147
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 110NDA-24158, Issue 2 Conference (Three/Four Party) 5. Multiline Terminals may allow other Multiline Terminals with the same line button appearance to enter the conversation (and therefore establish a Conference) by using the Privacy feature. Refer to the Privacy Fea- tures and Specifications for more information. 6. Once the second party answers, and prior to depressing the CNF key, Multiline Terminals may use the TRF or ANS key to...
Page 148
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Revision 2.1 Addendum-001 Page 111February, 1996 Conference (Six/Ten Party) Conference (Six/Ten Party) General Description This feature permits a station user or Attendant (conference leader) to establish a Conference among as many as six or ten parties (including the Conference leader). Station Application All stations and Attendant Consoles Operating Procedure Using the access code n To make a Conference Call 1. The Conference...
Page 149
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 112Addendum-001 NDA-24158, Revision 2.1 February, 1996 Conference (Six/Ten Party) 3. After the party answers, press the HOLD key. 4. Call all desired parties (station or C.O./tie line) sequentially, using other line keys, and placing each on hold after the party answers. 5. After holding the last party, press the Conference feature key. The line key associated with the last party lights green. The last party is connected to the CFT...
Page 150
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Revision 2.1 Addendum-001 Page 112-1February, 1996 Conference (Six/Ten Party) Service Conditions 1. Access codes A, B and C must be different numbers. A is used to reserve the Conference board. B is used to add Conference member. C is used to force release a member from the Conference. 2. Up to four CFT trunks (PN-CFTA) can be accommodated in the system. 3. The maximum number of participants which can be connected in a Conference...