Page 121

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 91
Call Park
Call Park - System
4. Dial the Call Park location number (00-19) and receive service set tone. (If Call Park-System number is
busy, dial another location number using the Step Call feature until an idle park location is accessed.)
5. Restore the handset.
n  From an Attendant Console
1. Dial Call Park-System feature access code. The first available Call Park location is selected by the system
and displayed in...

Page 122

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 92NDA-24158, Issue 2
Call Park
Call Park - Tenant
8. A call can be retrieved from Call Park-System while receiving feature dial tone.
9. If a station other than the station that originally parked the call retrieves the call, Station Message Detail
Recording (SMDR) will record a transfer.
10. Parked calls receive Music On Hold, if provided.
11. When a Call Park-System recalls to an Attendant Console, no LED indication is provided. However,...

Page 123

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 93
Call Park
Call Park - Tenant
To retrieve a call from Call Park-Tenant
n  From a Single Line Telephone
1. Go off hook and receive internal dial tone.
2. Dial the Call Park-Tenant retrieval access code.
3. Dial the Call Park-Tenant location number (1-8).
4. Converse.
n  From a Multiline Terminal with Call Park - Tenant feature key
1. Go off hook and receive dial tone.
2. Depress the Call Park - Tenant feature key...

Page 124

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 94Addendum-001 NDA-24158, Revision 2.1
February, 1996
Call Pickup
Call Pickup - Direct
Call Pickup
General Description
This feature enables a station user to answer any call directed to another station, to a station within their own
Call Pickup Group, or to a station within a different Call Pickup Group. Three Call Pickup methods are avail-
able: Call Pickup - Direct, Call Pickup - Group, and Call Pickup - Designated Group.
Call Pickup -...

Page 125

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Revision 2.1 Addendum-001
Page 94-1February, 1996
Call Pickup
Call Pickup - Direct
Service Conditions
1. All ringing calls directed to an extension, including voice calls, can be picked up by this feature, except for
Trunk Queuing - Outgoing and Call Back.
2. This feature can be activated from feature dial tone.
3. This feature may be allowed or denied based on station Class of Service.
4. A fully restricted station cannot pickup an...

Page 126

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 95
Call Pickup
Call Pickup - Group
Call Pickup - Group
General Description
This method permits a station user to answer any calls directed to other extensions in their preset pickup group
by dialing a Call Pickup - Group feature access code.
Station Application
All stations.
Operating Procedure
Ringing telephone in your Call Pickup Group:
1. Go off hook on an extension line and receive internal dial tone.
2. Dial the...

Page 127

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 96NDA-24158, Issue 2
Call Pickup
Call Pickup - Designated Group
4. Converse.
Service Conditions
1. All ringing calls directed to an extension in a Call Pickup Group can be picked up by this feature, except for
Trunk Queuing - Outgoing and Call Back.
2. This feature can not be activated from feature dial tone.
3. A fully restricted station cannot pickup an incoming Central Office call.
4. If more than one station within the group is...

Page 128

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Revision 2.6 Addendum-006
Page 96-1November, 1997
Call Redirect
Call Redirect
General Description
Without answering incoming calls or held calls which terminates to the line keys of a Multiline Terminal, the
calls can be transferred to a pre-programmed station or Voice Mail System. Two transferring destination number
can be designated per tenant, in system data programming. This feature can be used together with the Caller ID
Display...

Page 129

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 96-2Addendum-006 NDA-24158, Revision 2.6
November, 1997
Call Redirect
6. On the following conditions, the call cannot be transferred by the CRD key because the destination is re-
garded as busy state.
• When the call is a Camp-On call, and the destination is a UCD queue.
• When the call is held on an extension line/trunk access key, and the destination 
is a UCD queue.
• When the call is terminating to or held on a trunk access key, and...

Page 130

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 97
Call Transfer
Call Transfer - All Calls
Call  Transfer
General Description
This feature permits a station user to transfer a call to another station in the system directly, or with assistance
from the attendant.
Call Transfer - All Calls
General Description
This feature permits a station user to transfer incoming or outgoing calls to another station within the system
without attendant assistance.
Station Application...