Page 161

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 123
Diagnostics
Diagnostics
General Description
To assist maintenance personnel, the NEAX2000 IVS provides diagnostic capabilities such as fault code gen-
eration, device status information and alarm information recording which can be accessed from the Maintenance
Administration Terminal (MAT) or Customer Administration Terminal (CAT).
Station Application
Not applicable.
Operating Procedure
Refer to the NEAX2000 IVS...

Page 162

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 124NDA-24158, Issue 2
Dial Conversion
Dial Conversion
General Description
The system can be assigned to use rotary Dial Pulse (DP) or Dual Tone Multifrequency (DTMF) trunks and sta-
tions.  This feature provides for the repeating of digits dialed by the station user onto the C.O. trunks.
Station Application
All stations.
Operating Procedure
Normal call handling procedures apply.
Service Conditions
1. Trunks are assigned for DP and/or DTMF...

Page 163

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 125
Direct Data Entry
Direct Data Entry
General Description
This feature allows a maid or other hotel personnel to enter numeric data to the PMS (Property Management
System), using the guest room station for entry through dial operation. The same numerical data can be output
to a Hotel/Motel Printer by system data programming.
Station Application
All stations.
Operating Procedure
1. Lift the handset and receive dial...

Page 164

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 126NDA-24158, Issue 2
Direct Data Entry
8. There are two types of printout format for the Hotel/Motel Printer. The printout format can be selected by
the system data programming. The following figure shows examples of the printout format 1 and 2.
Example: Input data = 001*002*12345*3# (* is used to separate  the input data. * is not printed out but
sent out to  the PMS.)
1) The maximum number of characters per line is 20.
2) The maximum...

Page 165

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 127
Direct Data Entry
3) In Printout Format 2, even if the data corresponding QUANTITY is not entered, the system does not 
recognize that the data entry is an error (no reorder tone is received).
  Example: Input data = 1*2*3*#
1995 04/10 17:20 MON
NO.        220
CODE1              1
CODE2              2
CODE3              3
Printout format 1
1995 04/10 17:20 MON
NO.        220
CODE1              1
QUANTITY           2...

Page 166

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 128NDA-24158, Issue 2
Direct Digital Interface
Direct Digital Interface
General Description
This service feature provides the capability to connect trunks from the NEAX2000 IVS directly to T1 carrier
links using either a private or public network.
Operating Procedure
No manual operation is required.
Service Conditions
1. Each Office Heirarchy is defined as follows:
a) Master office
One center will operate as the Master Office.  This...

Page 167

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2 Addendum-007
Page 129August, 1998
Direct Digital Interface
6. The DTI can be provided with circuit cards to interface with T1 carrier.
7. The DTI boards are mounted in the AP board slot of the Port Interface Module (PIM).  
8. The following two methods may be used for network synchronization (see Figure 2 below):
a) Master - Slave System (Master)
b) Master - Slave System (Slave) 
9. The maximum number of trunks for DTI is 120...

Page 168

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 130NDA-24158, Issue 2
Direct Inward Dialing (DID)
Direct Inward Dialing (DID)
General Description
 This feature provides for incoming calls from the exchange network (except FX or WATS) to reach any station
within the system without attendant assistance.
Station Application
Not applicable.
Operating Procedure
The calling party outside the system dials the appropriate telephone number.  The call will ring directly at the
called station,...

Page 169

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 131
Direct Inward Dialing (DID)
DID Call Waiting
DID Call Waiting
General Description
 This feature allows an incoming call on a DID trunk or a tie line to automatically be Camped-On to the desti-
nation station if the destination station is busy.
Station Application
All stations.
Operating Procedure
The camp-on occurs automatically once this feature is assigned.  For details on how to respond to the camp-on,
refer to...

Page 170

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 132NDA-24158, Issue 2
Direct Inward System Access (DISA)
Direct Inward System Access (DISA)
General Description
This feature allows an outside caller to access the system using an exchange network connection without Atten-
dant or station assistance.  The outside user may originate calls over any or all of the systems facilities such as
WATS, FX, Tie Line or CCSA.  The outside user can also directly call stations and access miscellaneous...
Start reading NEC Neax 2000 Ivs Business/Hotel/Data Features And Specifications