NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 188NDA-24158, Issue 2 Least Cost Routing - 3/6 Digit Least Cost Routing - 3/6 Digit General Description This service feature allows the NEAX2000 IVS to be programmed to route outgoing calls over the most eco- nomical facility (WATS, FX, DDD). Based on the individual area code and office code dialed (6-digit analysis), the system examines the programmed tables and uses the trunk in the order specified. Station Application All stations....
Page 232
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Revision 2.8 Addendum-008 Page 189 February, 1999 Least Cost Routing - 3/6 Digit entries are required, up to 8 entries can be provided by combining two route pattern tables. • LCR Pattern Table - Up to 256 tables are available for assignment of digits to be added or deleted. Also, the office code dialed can be checked to determine whether service is available for a specific office code, and whether a prefix 1 should be added....
Page 233
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 190NDA-24158, Issue 2 Least Cost Routing - 3/6 Digit Is first digit an LCR access code? START NoNormal operation (no LCR) Get LCR code to digit code development pattern Is an LCR code to digit development pattern as- NoReorder tone signed?Yes Yes Receive next digit Check assignment for matched pattern Is a match found?No Yes Is a digit code development pattern as-YesCheck new digit code development pattern table signed? No Is a day of...
Page 234
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 191 Least Cost Routing - 3/6 Digit Is a time of day pattern assigned?Yes No Is a tenant pattern assigned?Yes Get route pattern to be used No Is a route pattern Yes Reorder tone assigned? No A B Check time of day assignment D What pattern is assigned? Get first priority route and go to assigned LCR/TR table TenantRouteNone C Is a trunk restriction pattern as- signed?Yes No Is trunk route busy?Yes No Is a 6 digit...
Page 235
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 192NDA-24158, Issue 2 Least Cost Routing - 3/6 Digit Is a digit addition pattern as- signed?Yes No E Check digit addition pattern; add digits accordingly Delete area code?Yes NoDelete area code Delete all digits?Yes NoSeize a trunk in first trunk route Number of digits to be deleted?Yes NoDelete digits accordingly Seize a trunk in selected priority trunk route and dial
Page 236
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 193 Line Lockout Line Lockout General Description This feature automatically releases a station from the common equipment if the station remains off-hook for longer than a programmed interval before dialing. Howler tone may be programmed to be sent to the station in Line Lockout. Station Application All stations. Operating Procedure For Line Lockout 1. The station user goes off-hook and receives dial tone. 2. f the user...
Page 237
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 194NDA-24158, Issue 2 Line Preselection Line Preselection General Description This feature provides the station user with two ways to select an idle, held, recalling, or ringing line before going off-hook. Station Application All Multiline Terminals. Operating Procedure 1. Press the desired line key. 2. Lift the handset or press the SPKR key and receive dial tone or answer the incoming call. OR 1. Press the line key and receive dial tone...
Page 238
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 195 Maid Status Maid Status General Description This feature allows the Hotel/Motel (H/M) Front Desk Instrument, Property Management System (PMS) termi- nal, or guest room station (using special access code) to register the condition of each guest room. Station Application All stations except House Phones. Operating Procedure To set Maid Status from the Hotel/Motel Front Desk Instrument 1. Depress the STS key. 2. Dial...
Page 239
NEAX2000 IVS Business/Hotel/Data Features and Specifications Page 196NDA-24158, Issue 2 Maid Status Service Conditions 1. There are a maximum of 8 types of room conditions as follows: 2. Although the system provides for a maximum of 8 types of room conditions, the 8 codes (1-8) provided are not fixed for a given condition. This provides the end user with the flexibility to select any code (1-8) to serve as the Maid Status code for any condition. When Maid Status is displayed, or printed out, the...
Page 240
NEAX2000 IVS Business/Hotel/Data Features and Specifications NDA-24158, Issue 2 Page 197 Maintenance Administration Terminal (MAT) Maintenance Administration Terminal (MAT) General Description The Maintenance Administration Terminal (MAT) is a Personal Computer (PC) used for programming and maintenance of the NEAX2000 IVS. The MAT can provide a Maintenance Printout, Peg Count information and fault message output. Additionally, the MAT can be used to Remove and Restore to Service any station in the...