Page 141

CP 6267Page3 of5
VoiceMemo Release 6.OA and later
StepReference
6.The system displayed the installed disks and the current configuration. If the
configuation is correct, continue with the reload.
Prompt: * * *INSTALLED
DISKS 
***
BUS 0Disk 0
----__
2049 MB
.TION
******CONFIGURA
Drive 1+-----------+---------+
1 Active 1  0:O+-----------+---------+
(C) - CONTINUE
configuration is correct
(S) 
- SCAN all disks
installed disks
(X) - EXIT disk configuration
configuration
Enter desired option (C/S/X/?Response:...

Page 142

 rCl? 6267
Page 4 of 5VoiceMemo Release 6.OA and later
Step
9.The server then requests the remaining diskettes. Insert the diskettes when
prompted.
Prompt: When drive light goes out insert disk 2 and press
return
Response: Insert the specified diskette then press Enter to continue.
10. After all the software diskettes have been loaded, load the prompts.
Prompt: Do you want to install prompts to the system Y/N:
Response: Y8.11. Load the prompts diskettes.
Prompt:Insert the 1st diskette containing the...

Page 143

Cl’ 6267
Page 5 of 5VoiceMemo Release 6.OA and later
StepReference15. To complete the update process, you must load the Module Enable diskette and all
the optional features.
Prompt:Does the system have Optional Features?
Response: Y16. Load the Module Enable diskette or the optional feature.
Prompt: Insert Optional Feature Setup diskette in the
floppy drive
Biter  when ready :
Response: Insert the diskette, then press Enter.17. The server loads the feature and asks if there are more.
Prompt: XXX Optional...

Page 144

Shut Down a Systemcp 6268Page 1 of 2
VoiceMemo Release 6.OA and later
This procedure describes how to shut down a module running Release 6.0. You should
use this procedure before turning off the power to a Series 6 server module, as the
shutdown command halts call processing in a clean and orderly fashion.
FOR THE MODEL 120 AND MODEL 70 ONLY: Some system prompts in this
procedure may contain generic references to other multiple-module Centigram Series 6
products. In such cases, shaded areas indicate a...

Page 145

CP 6268Page 2 of 2
VoiceMemo Release 6.OA and later
StevResponse: Y to wait for the queue to clear,
N to continue immediately with the shutdown.
5.When the Series 6 server has taken all lines of the specified modules off-hook, it
continues by asking if a verify is to be executed.
Prompt:
Perform Offline System Verification? (Y/N):Response: Y to execute the verify,
N to skip verify and continue with the shut down.
6.Specify if changes to the status of each module are to be made.
1.
prompt: Enable or...

Page 146

cp 628 1Redundant Disk Addition (make.redundant)Page 1 of 5
VoiceMemo Release 6.OA and later
This procedure describes how to add storage redundancy by adding another disk to a
non-redundant Centigram Series 6 server. The new disk is called the redundant disk
and stores a mirror image of all data on the primary (original) disk. This procedure can
be performed while the server is online.For instructions describing how to increase the
storage capacity to a server by adding another primary disk, see CP 6282,...

Page 147

 rCl? 6281
Page 2 of 5VoiceMemo Release 6.OA and later
steb
CGl3 Prepare the New Disk
1.Determine how to jumper the new hard disk as an IDE “slave” disk.
2.Jumper the new hard disk. If there are two hard disks in one server, one must be
configured as master and the other must be configured as slave. If there is one hard
disk in the server, it must be configured as master. IDE hard disks are shipped from
Centigram configured as master.
CC9 Prepare the System3.Reach the Hard Disk Utilities Menu, then go to...

Page 148

Cl? 6281
Page 3 of 5VoiceMemo Release 6.OA and later
Step
GD Run the Make Redundant Program From the Hardware
Configuration Menu10. Turn on the power to the system, and boot from the hard disk.
11. Reach the 
VoiceMemo Hardware Configuration Menu, then to go the Disk
Configuration Menu.
12. Add the redundant disk.
Select:(M) Make a Disk Redundant
r.
Ib?ip t:Please insert service diskette3 into floppy
drive,hit  when ready
Response: Insert the Service Diskette, and press Enter.
Prompt: Active Disk:...

Page 149

Cl’ 6281
Page 4 of 5
VoiceMemo Release 6.OA and later
Step16. The server reads from the diskette, and asks which process you want to execute.
Prompt: Enter one of the names:
Response: make.redundant
17. The server reads from the diskette, and issues a warning about the pending process.
Prompt: *****WARNING: REDUNDANT PROGRAM*******
REDUNDANT program is used to make a primary
disk have a mirror-image secondary disk. Any
data on the primary disk will also be recorded
on the secondary disk.You must have the...

Page 150

Cl? 6281
Page 5 of 5VoiceMemo Release 6.OA and later
StepReference19. Acknowledge the end of the process.
Prompt BUILD REDUNDANT DISK DONE. ENTER A CARRIAGE
RETURN TO REBOOT THE SYSTEM
Response: Press Enter.
20. Reach the System Maintenance Menu, then go to the Module Maintenance Menu.
2 1. Update the redundancy of the new disk and all other disks that were affected by the
shutdown.
,,Menu Map 12
cl? 7015 