    							Programming
    51
    Programming
    DATASET Printer Port
    1. DNI Circuit Assignment form
    !Assign DS110x or DS210x against channel #2 of the 
    required PLID.
    2. Dataset Circuit Descriptor Assignment form
    !Create a circuit descriptor.
    !Set Device Class = DS1100s or DS2100s.
    !Set Defaults = Yes.
    3. Dataset Assignment form
    !Assign Port = YES against the dataset’s PLID.
    !Assign the circuit descriptor to the dataset.
    !Assign an interconnect number to the dataset.
    4. System Port Assignment form
    !Assign a port name to the PLID of the DATASET’s 
    output channel (channel #2).
    5. Application Logical Port Assignment form
    !Assign the port name to each application from which 
    you would like to print reports. 
    						
    							Technician’s Handbook
    52
    Programming Peripheral Devices
    Single Line Telephones
    Before You Begin
    Program Class of Service, Interconnect Restriction, and 
    Intercept Handling (see page 47).
    1. System Configuration form
    !For standard telephones, add an ONS, ONS 
    CLASS/CLIP, or OPS line card.
    !For SUPERSET 401+ or SUPERSET 4001 
    telephones, add a DNI line card.
    2. For SUPERSET 401+ and SUPERSET 4001 
    telephones:
    DNI Circuit Assignment form
    !Program the set type to channel #1 of the circuit.
    For standard telephones:
    ONS/OPS Circuit Descriptor form
    !Change the circuit descriptor contents (if required).
    !For OPS circuits, change the transmission parameter 
    to LONG.
    !For ONS circuits, change the transmission 
    parameter to SHORT.
    Note:The SUPERSET 401 telephone does not have a 
    descriptor. 
    						
    							Programming
    53
    Programming
    3. Single Line Set Assignment form
    !Assign a directory number, circuit descriptor number, 
    and interconnect number to the circuit.
    4. (Optional) Default Account Code Definition form 
    !Create a default account code number that will 
    appear in all SMDR records for the station.
    5. Station Service Assignment form
    !Assign the telephone’s directory number a class of 
    service, class of restriction, and intercept number.
    !(Optional) Assign a default account code index 
    number. 
    						
    							Technician’s Handbook
    54
    Analog Devices Connected to an AIM
    Before You Begin
    Program Class of Service, Interconnect Restriction, and 
    Intercept Handling (see page 47).
    To program analog devices connected to a Mitel Networks 
    5422 Analog Interface Module:
    1. System Configuration form
    !Program a DNI line card.
    2. DNI Circuit Assignment form
    !Program set type against channel #1 of the circuit.
    !Program the AIM against channel #2 of the circuit.
    3. ONS/OPS Circuit Descriptor Assignment form
    !Change circuit descriptor contents (if required).
    !Change the transmission parameter to SHORT.
    4. Single Line Set Assignment form
    !Assign a directory number, circuit descriptor number, 
    and interconnect number to the circuit.
    5. Default Account Code Definition form (Optional)
    !Create a default account code number that will 
    appear in all SMDR records for the station.
    6. Station Service Assignment form
    !Assign the telephone’s directory number a Class of 
    Service, Class of Restriction, and Intercept Number.
    !(Optional) Assign a Default Account Code Index 
    Number. 
    						
    							Programming
    55
    Programming
    Multiline Telephones
    Before You Begin
    Program Class of Service, Interconnect Restriction, and 
    Intercept Handling (see page 47).
    1. System Configuration form
    !Program a COV or DNI line card.
    2. DNI Circuit Assignment form
    Note:This step does not apply to SUPERSET 4 telephones.
    !Program the set type to channel #1 of the circuit.
    !If the telephone connects to a PKM, program the 
    PKM to channel #2. If the telephone connects to an 
    analog device, program the AIM to channel #2.
    If you program the AIM to channel #2, you must also 
    program the connected analog devices. See Analog 
    Devices Connected to an AIM on page 54.
    3. Multiline Set Assignment form
    !Program a prime directory number and an 
    interconnect number to a line circuit.
    4. Multiline Set Key Assignment form (Optional)
    !Assign a directory number (line appearance) or 
    feature to each key.
    !Assign each line appearance a ring type.
    5. Multiline Set Group Assignment form (Optional)
    !Change the ring type at each telephone where the 
    number appears.
    !Change the group type from “key system” to 
    “multicall” or vice versa. 
    						
    							Technician’s Handbook
    56
    6. Default Account Code Definition form (Optional)
    !Create a default account code number that will 
    appear in all SMDR records for the station.
    7. Station Service Assignment form
    !Assign the telephone’s directory number a class of 
    service, class of restriction, and intercept number.
    !(Optional) Assign a default account code index 
    number.
    Programmable Key Module
    The PKM12, PKM48, and Dual PKM are programmed in the 
    same way. You can only program the first 12 keys on a 
    PKM12.
    1. DNI Circuit Assignment form
    !Locate the PLID of the device to which the PKM is 
    connected.
    !Select PKM12, PKM48, or Dual PKM in the 
    Channel #2 field.
    2. Multiline Set Key Assignment form
    !Program the keys.
    Upgrade a PKM
    To change your PKM12 to PKM48, Dual PKM, or add a 
    second PKM48 to a SUPERSET 4025 or SUPERSET 4150:
    1. DNI Circuit Assignment form
    !Locate the PLID of the PKM-connected device.
    !Change the PKM type in the Channel #2 field.
    2. Multiline Set Key Assignment form
    !Program the additional keys. 
    						
    							Programming
    57
    Programming
    Attendant Consoles
    Before You Begin
    Program Class of Service, Interconnect Restriction, and 
    Intercept Handling (see page 47).
    1. System Configuration form
    !Add a DNI line card.
    2. DNI Circuit Assignment form
    !For a SUPERCONSOLE 1000 or SUPERSET 7000, 
    program the set type to channel #1 of a DNI circuit.
    !For a SUPERSET 700, program SUPERSET 7 to 
    channels #1 and #2 of a DNI circuit.
    !For a SUPERCONSOLE 2000, program SC2000 to 
    channels #1 and #2 of a DNI circuit.
    3. Attendant Assignment form
    !Assign a prime directory number to the console 
    circuit PLID and a key appearance.
    4. Attendant Softkey Assignment form
    !Recall the prime directory number of the console.
    !Assign directory numbers to the console softkeys 
    (key #1 is reserved for recall functions).
    5. Telephone Directory form
    !Assign names to the console softkey directory 
    numbers.
    6. (Optional) Default Account Code Definition form 
    !Create a default account code number that will 
    appear in all SMDR records for the station. 
    						
    							Technician’s Handbook
    58
    7. Station Service Assignment form
    !Assign the console’s directory number a class of 
    service, class of restriction, and intercept number.
    !(Optional) Assign a default account code index 
    number. 
    						
    							Programming
    59
    Programming
    Programming the Telephone Directory
    Telephone Directory form
    !Assign a name to the telephone’s directory number.
    !If more than one name is assigned to the same 
    telephone number, enter “Y” in the Prime Name field 
    to indicate the prime name.
    !If the telephone number is not to appear on the 
    display of other telephones during a call, enter “Y” in 
    the Prv # field.
    !(Optional) Assign a department and location name to 
    the telephone’s directory number. 
    						
    							Technician’s Handbook
    60
    Changing a Telephone’s Attributes
    1. Change Attribute Assignment form
    !Enter the directory number of the device and recall 
    the form.
    2. Change any of the following database parameters:
    !Department name for the user
    !Location of the user
    !Default account code index number
    !Intercept number
    !Interconnect number
    !Circuit descriptor
    !Class of service and class of restriction
    !Maximum number of speedcalls available
    !Pickup group number
    !Station hotline number
    !Associated dataline number
    !1st, 2nd, and Always call rerouting numbers
    To move a user from one telephone to another, or to 
    exchange telephones between two users, use the MOVE 
    command, rather than the Change Attribute Assignment 
    form. See Moving a Telephone User on page 61. 
    						
    All Mitel manuals Comments (0)

    Related Manuals for Mitel Sx-2000 Llightware 32, Release 1.0 Technicians Handbook