    ROUTINE MAIINYENANCE 
    Al.01 The procedures described in the following paragraphs, are the 
    only routines required for the SX-200@ DIGITAL PABX, and are 
    necessary due to the mechanical nature or limited operational life of 
    the components concerned. 
    Air Filter 
    Al.02 An air filter is positioned in the SX-200@ DIGITAL PABX control 
    cabinet to remove dust and particles from the air flow so as to 
    maintain a clean environment within the cabinet. It is important that 
    the filter be checked frequently, and cleaned regularly, since failure to 
    do so will cause a reduction in the airflow, and a consequent buildup 
    of excess heat within the cabinet, leading ultimately to component 
    failure. 
    AI.03 The air filter is located on the inside of the control cabinet front 
    door, 
    at the bottom. It is held over the intake vent by a velcro 
    strip bordering the vent. To remove the filter, simply pull it from the 
    velcro strip border. To install the filter, simply place it over the vent, 
    and firmly press the edges onto the velcro border: 
    Al.04 The filter may be cleaned by washing in hot water and deter- 
    gent. After several washings, the filter may begin to deteriorate; 
    at this point, it should be replaced. 
    Al.05 The intervals at which this should be done will depend upon the 
    environment in which the SX-200@ DIGITAL PABX is located. 
    Regardless of environmental considerations, however, the filter should 
    be changed at least every 6 months. 