    							RS-232 Maintenance Terminal 
    APPENDIX B 
    MAINTENANCE TERMllNAL ERROR MESSAGES 
    81.01 The following Table lists all of the status and error messages 
    which may appear at the maintenance terminal during a main- 
    tenance session: 
    TABLE 81-l 
    MAINTENANCE TERMINAL ERROR MESSAGES 
    SHOW STATUS command to check the status 
    Use SHOW CONFIG command to check the 
    The specified sub-circuit number is invalid for 
    this particular device type. Use SHOW STATUS 
    command to verify card type and number of 
    Device could not be returned to service The device was already in service. Use SHOW 
    S command to verify the circuit’s 
    and press CANCEL.. 
    m software. New diskette may be 
    Page B-l  
    						
    							RS-232 Maintenance Terminal 
    TABLE al-1 (CONT’D) 
    MAINTENANCE TERMINAL ERROR MESSAGES 
    DATABASE sequence - try again when the 
    system is less busy. May be problem with 
    communication with diskette - check the 
    connections to the disk drive. Verify that there 
    is a diskette in the drive. Repeated failure 
    indicates a problem - refer to Section 
    MITL9108-093-350-NA, Troubleshooting. 
    IC measurement 
    is collecting data. 
    Specifically, these are: 
    from the console, the diskette is first updated. 
    This indicates failure of this stage. Check for 
    presence of a diskette in the drive. Ensure the 
    disk drive door is closed. 
    Page B-2  
    						
    							RS-232 Maintenance Terminal 
    TABLE al-1 (CONT’D) 
    MAINTENANCE TERMINAL ERROR MESSAGES 
    - disk drive door is open 
    - there is no diskette installed. 
    TENANCE-PORT 
    when ready an an error 
    ears when changing the speed 
    ort while on the 
    Bay/Slot/Cct. of entering def 
    and SUBCIRCUI 
    “XX” in Bay/Slot/Cct. 
    Circuit XX does not exist on this card. 
    out of range ( 1 - 4 ). module number is out of range (i.e., not 
    between 1 and 4). 
    Universal Card. Sub-circuit X does does not 
    exist on module YY. The user has chosen a Universal card; the 
    module number is valid and exists but the i 
    sub-circuit number specified does not. 
    Page B-3  
    						
    							RS-232 Maintenance Terpinal 
    TABLE B.l-1 (CONT’D) 
    MAINTENANCE TERMINAL ERROR MESSAGES 
    mmands both the bay a 
    specified explicitly. 
    to check range. 
    TIMEOUT PERIOD EXPIRED. Press Return to 
    login. 
    Copy failed. Disk is write protected. a copy-protected 
    rotect tab, or insert 
    Page B-4/4  
    						
    							RS-232 Maintenance Terminal 
    APPENDIX C 
    lNSTALLAl-ION OF NEW SOFTWARE 
    Cl.01 This Appendix outlines the procedures involved in the installa- 
    tion of new or upgraded software. Additional information may 
    be found in Section MITL9108-093-200-NA, Shipping, Receiving 
    and 
    Installation. The SX-200’ DIGITAL PABX software is stored on a single 
    5 l/4 inch floppy diskette; the database is also stored here. When 
    upgraded software is procurred, it is desirable to simply copy the 
    customized database from the old software diskette onto ttie new 
    software diskette, rather that re-entering the database manually. The 
    procedures for this are outlined below. 
    Procedure 
    Cl.02 It is important to note that these procedures involve a complete 
    reset of the system (needed to initialize the new software). 
    Therefore, this procedure should be done only at night, or during a 
    period of low traffic to ensure minimum effect upon system users. To 
    install new software, follow the following procedures in Table Cl-l.. -- 
    TABLE Cl-l 
    -. NEW SOFTWARE INSTALLATION 
    i L : i :’ ‘.. 
    Step Procedure (“;, ;-,’ 
    ,y’, ‘:“..y .’ .- 
    1 Select the MAINTENANCE application at the maintenance terminal, and log in. See 
    Paragraph 2.05 of this Section. 
    I 2 1 Press the SYSTEM softkey to access the System Level in the Maintenance Application. 1 
    3 
    4 To record the database, enter the following softkeys: 
    COPY 
    DATABASE 
    ENTER 
    Wait for the database to be read into DRAM; this is complete when the following 
    message is presented at the maintenance terminal: 
    Insert new disk, close door and press CONTINUE. 
    I 5 ( Remove the original floppy diskette from the disk drive. 
    I 
    6 Insert the new software diskette into the disk drive, and move the latch into the closed 
    position. 
    9 Press the CONTINUE softkey to write the database on to the new floppy diskette. 
    8 Wait for the write to complete; this is indicated by the following message: 
    Copy successful. Press CANCEL to continue. 
    Page C-l  
    						
    							RS-232 Maintenance Terminal 
    TABLE Cl-l (CONT’D) 
    NEW SOFTWARE INSTALLATION 
    I I I 
    Step Procedure 
    9 
    ress the CANCEL softkey, and 
    software. 
    Note: It will be possible to log into the maintenance terminal approximately 2 minutes 
    after pressing the SYSTEM RESET pushbutton. 
    Page C-2/2  
    						
    							MITEL STANDARD PRACTICE SECTION MITL9108-093-353-NA 
    issue 2, September 1986 
    SX-200” DIGITAL 
    PRIVATE AUTOMATIC BRANCH EXCHANGE (PABX) 
    GENERAL MAINTENANCE INFORMATION 
    Copyright of MITEL Corporation 1986 
    TM - Trademark of MITEL Corporation 
    @Registered Trademark of MITEL Corporation  
    						
    							General Maintenance information 
    CONTENTS 
    PAGE 
    1. INTRODUCTION ................................... l-l 
    General ........... . ............................. l-l 
    Reasonforlssue ................................. l-l 
    The SUPERSET qTM Set ............................. l-l 
    The SUPERSET 3TM Set ............................. l-l 
    2. SYSTEM OVERVIEW ................................ 2-l 
    General ......................................... 2-1 
    Maintenance ..................................... 2-l 
    Physical Description ............................... 2-l 
    Control Equipment Cabinet ......................... 2-l 
    Peripheral Equipment Cabinet ....................... 2-6 
    Digital Equipment Bays ............................ 2-6 
    Analog Equipment Bays ............................ 2-6 
    Main Control Card ................................ 2-6 
    Technical/Electrical Characteristics ................... 2-6 
    Attendant Console ................................ 2-6 
    3. MAINTENANCE AIDS ............................... 3-l 
    The Maintenance Terminal .......................... 3-l 
    Control Cabinet Maintenance Panel .................... 3-l 
    -Peripheral Cabinet Maintenance Panel ................. 3-6 
    System Maintenance Log ........................... 3-6 
    4.ALARMS ........................................ 4-l 
    General ......................................... 4-l 
    Alarm Levels ..................................... 4-l 
    Alarm Categories ................................. 4-l 
    Alarm Types ..................................... 4-1 
    Alarm Thresholds ................................. 4-2 
    Alarm Totals ..................................... 4-2 
    5. THE MAINTENANCE MANAGER ....................... 5-l 
    General ......................................... 5-l 
    Diagnostic Test Queues ............................ 5-l 
    Testing ......................................... 5-2 
    Fault Recovery ......................... . ......... 5-3 
    The Maintenance Database ......................... 5-3 
    6. DIAGNOSTIC TESTS ................................ 6-l 
    General ......................................... 6-l 
    Main Control Card Tests ........................... 6-2 
    Bay Control Card Tests ............................ 6-3 
    Peripheral Control Complex Tests ...... ; ............. 6-3 
    Peripheral Device Tests ............................ 6-3 
    7. TEST LINE m..m 0 m . . . ..s.m . . ..m ..o.m m .a m n ..r.o..... 7-l 
    General ..- ..m...........D ....D..........,......O 7-l 
    Connection to Test Line . . . . . D 0 e s D p . . D . n . . 0 . . . . . . . m . 7-l 
    . . . 
    III  
    						
    							General Maintenance information 
    COiTENTS (CONT’D) PAGE 
    Programming . . . . . . . . . . . . . . . . . . . . 0 . . . . a . . . . . n e . , . . 7-l 
    Test Line Access 
    . . . . . . . . . . . . . . . . . . . . . . . 0 . . . e . . . a m 7-1 
    Test Line indicator LEDs . . . , . . . . . . . . . . . . . . . . . . . . . . . . 7-2 
    Test LineTones . ..~.....~D.........~............. 7-2 
    Command input . . . . . . . . . . . . . . . . ..-......-........ 7-2 
    Commands Available D . . . . a . . . . . . . . . . . a n . 0 . . e . m . .:-7-4 
    Specifying Equipment . . . . . , . . m . . . . . . . D . . m e . . . D m s D n . 7-4 
    Normal Extension Calls . . . . . . , . . . . . . . . . . . . . . 0 . n . . . . 7-5 
    Direct Trunk Select Command (DT) . 0 . . . s . . . . V . e . 0 0 s m s 7-5 
    Busy-Out Command (BO) . . s . s . . e . . . e . . . . a a m m . . . , . . . 7-5 
    Return Device To Service Command (RS) s n . 0 0 D . e e m m . m ti 0 7-5 
    Busy-Out Junctor Command (BJ) 
    Q e . 0 0 0 D . m D s II 0 a n . . . D . 7-5 
    Return Junctor To Service Command (RJ) n . m a m m . . . n m . . . 7-6 
    Test Device Command (TD) . , 0 e s D D . . a D V e B . s D s . . 0 . . . . 7-6 
    Test Junctor Command (TJ) D . . s 0 Q . . m . 0 0 0 . . , m . . . e . 0 . = 7-6 
    Dump Logs Command (DL) I -. . . 0 O.. 0 -. -. c . . s n.. . . -. . 7-6 
    Test Printer Command (TP) I r 0 s s 0 D 0 . II r m r a . . . , s D . s . D m 7-6 
    Copy Database Command (CD) 0 . 0 0 . 0 a e m . r e D m 0 r . n 0 . 0 n n 7-6 
    8. MAINTENANCE CONTROLS AND INDICATORS . . I.. e.. . m 0 0 8-1 
    General .q ..........D m..D.s.s.m..s s O.s ..- r D..D -.- 8-l 
    Maintenance Panels . . . . . . . e . . I . . . . 0 . s D . s . s n a . . s s s D 8-l 
    Main Control Card . . . . . . . I n D I . . . . . 0 e 0 . . D . a e z s s 0 D . m 8-l 
    Bay Control Card 
    . s e m D . m o 0 LI . . II . m . . D 0 n D . 0 s D . . D D s D n . 8-3 
    Peripheral Control Card D . D 0 m s . . a . m f . 0 s m 0 . r D V m s . c e LI e 8-4 
    Digital Interface Card . . . . . . . e . . a . . . . . 0 . . . 0 0 Ij . . 0 s . D n 8-4 
    Scanner Card . . . ..- e n *..-.....-...- o s a *.- D.D D O..r 8-6 
    Peripheral Circuit Cards . . . n s . . . . . . . D m n . s m . . s . . . m . e n 8-7 
    Attendant Console ..n..............O..O.....,.n D s n 8-7 
    Power Supplies .....n....ti -........- m *.-.- e -...- D 8-10 
    Floppy Disk Drive . . . . . . . . . . . . . . . . . . . 0 . . . m r D D D q . a m 8-10 
    Power Fail Transfer Card . . . . 0 . 0 m . 0 . . 0 0 s D . m . Q m s . . D . 8-10 
    APPENDIX A 
    ROUTINE MAINTENANCE . . . s . . . n s 0 s s . . . . 0 . . m . 0 m n s v m e A-l 
    LIST OF ILLUSTRATIONS 
    FIGURE TITLE PAGE 
    2-l System Block Diagram (336-Port Configuration) m e . D 2-2 
    2-2 System Block Diagram (480-Port Configuration) 0 . . a 2-3 
    2-3 SX-200@ DIGITAL Equipment Cabinets (336-Port 
    Configuration, Universal SX-200@ DIGITAL Control 
    Cabinet) D 0 es m..s D m .m n D s m D 0 s D 0 0 D D D e 0 s D D D a n m 2-4 
    2-4 SX-200@ DIGITAL Equipment Cabinets (480-Port 
    Configuration, Standard SX-200@ DIGITAL Control 
    Cabinet) O........O......s D s 0 m s O.Q s s ..O m D 0 s 2-5 
    iv  
    						
    							General Maintenance Information 
    FIGURE TITLE PAGE 
    2-5 Attendant Console . . . . . . . D . . . . . . . . . . . . . . . . . . . 2-7 
    3-1 Maintenance Terminal Connection (Universal SX-200@ 
    3-2 
    3-3 
    3-4 
    3-5 
    8-l 
    8-2 
    8-3 
    8-4 ’ 
    8-5 
    8-6 
    8-7 
    8-8 
    8-9 DIGITAL Control Cabinet) . . . . . . n . . . . . s m . . . . . . . 3-2 
    Maintenance Terminal Connection (Standard SX-200@ 
    DIGITAL Control Cabinet) n . . . . . . . . . . . . . . . . . . n . 3-3 
    SX-200@ DIGITAL Control Cabinet Maintenance Panel 
    (Universal SX-200@ DIGITAL Control Cabinet) . . . m . 3-4 
    SX-200@ DIGITAL Control Cabinet Maintenance Panel 
    (Standard SX-200@ DIGITAL Control Cabinet) . . . . . 3-5 
    Peripheral Cabinet Maintenance Panel . D . , . . D . . . . . 3-7 
    Control Card Front Panels . s 0 . 0 u 0 . . . m D . . a . . s . s r 8-2 
    Peripheral Card Front Panels . . , . 0 . . . . . . . . s . . . . . 8-8 
    Attendant Console Keyboard . . . e . . . . . . . . . = . . . . . 8-9 
    Rear Door Power Supply Indicators m n . . . . D . . . . . . 8-11 
    BayPowerSupply . . . . . DI . . ...* De.0 . . . . . . . . . . 8-12 
    SX-200@ DlGlTALDiskDrive ...OOODn.n..nDa.... 8-13 
    Power Fail Transfer Card Location - Peripheral 
    Cabinet.. s D m ...e.n.O ..r..*0 s ...m s.e 0 s ..O. 8-14 
    Power Fail Transfer Card Location - Universal 
    Control Cabinet = . . . 0 . 0 n . e a . . . a . . . . m s . m . . . . 8-15 
    Power Fail Transfer Card (480-Port Configuration) . 8-16 
    LIST OF TABLES 
    TABLE 
    1-l 
    4-l 
    5-l 
    5-2 
    6-l 
    6-2 
    6-3 
    6-4 
    6-5 
    6-6 
    6-7 
    6-8 
    6-9 
    7-1 
    7-2 
    7-3 
    8-l 
    8-2 
    8-3 
    8-4 
    8-5 
    8-6 
    8-7 TITLE PAGE 
    SX-200@ DIGITAL Practices . s D e . . . m a . a 0 . . s s . . . . . l-l 
    Alarm Thresholds 0 0 . s D . . . s . . . . . m e . . a . . s . e . . . . 4-2 
    Diagnostic Test Queues . . . . . . . s e m . . . D . . . . . . 0 0 . 5-l 
    The Maintenance Device Work Area . . . . . . . . . . e . e . 5-4- 
    Diagnostic Types e . e . . . . s . . . . . . . e . . e . . . . . . . . . 6-l 
    Diagnostic Coverage s . D . . D . . . . . s . . s . . . . . s . s . . . 6-2 
    ONS/OPS Line Diagnostic Sequence . . . n i . . m . . . . . 6-5 
    LS/GS Trunk Diagnostic Sequence s r . 0 . . B m . . . D . . 0 6-5 
    DTMF Receiver Diagnostic Sequence . . . . . . . . . . . . . 6-5 
    Console Diagnostic Sequence . . . . . . . . e . 0 . D . s m . . 6-6 
    Analog Voice Path (Junctor) Diagnostic Sequence . . 6-6 
    COV Line/E&M Trunk Diagnostic Sequence 0 . . . . . . . 6-6 
    DID Trunk Diagnostic Sequence Q . . . . m . 0 0 . s . . . . B . 6-6 
    Test Line Command Codes . . . . . . . . . . . . . . n . 0 . . . 7-2 
    Test Line Status indicator Codes . . . . . . . 0 D s . . . . . . 7-3 
    Test Line Status Tones . . . . . . . . . . . . . D D . D . . . . . . 7-4 
    Main Control Card Test Status Codes . . s 0 . . . . . . . . 8-3 
    Diskette Error Codes . . . . . . . . . . . . . . . . . . . 0 . . . . . 8-4 
    Bay Control Card Status LEDs . . . . . . 0 . s . . . . . s . . . 8-5 
    Peripheral Control Card Test Status Indicators . 0 . . . 8-5 
    Digital Interface Card Test Status Indicators , . . . . . . 8-6 
    Attendant Console Maintenance LED indicators . . . . 8-7 
    Attendant Console LCD Display Messages D D . . . . . 8-10  LIST OF ILLUSTRATIONS (CONT’D) 