Page 311
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 257 Assign Line Side DEFINITY Protocol to Digital Circuit CardsNote:Before a new protocol can be assigned to a circuit card, any existing protocol must first be “unassigned.” See Unassign Line Side DEFINITY Protocol to Digital Circuit Cards on page 268 for more information. Before attempting to make any assignment changes to circuit cards, they must be in...
Page 312
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 258 Figure 132. Assign Card: Line Side DEFINITY Window 2 Enter the circuit card number in the Card Number: field, or press F2 (Choices) to select from a menu. Initially, all fields are populated with the default values for the circuit card number entered. The Card Number: field is blank in Figure 132 on page 258 . After you enter the circuit card...
Page 313
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 259 The LSE1-specific fields are:~ Idle Code ~ A-LAW or MU-LAW ~ CRC The LST1-specific field is: ~ CSU Distance 3 Enter the name of the country in the Country: field, or press F2 (Choices) to select from a menu. 4 Enter Yes to enable or No to disable in the DTMF Muting: field, or press F2 (Choices) to select from a menu. Yes is the default. Enter...
Page 314
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 260 6 Enter the duration of the on-hook signal used to initiate a transfer in the Switch Hook Flash Duration: field. Valid values are multiples of 10 ranging from 10–2550. If you enter a value that is not a multiple of 10, the value is rounded down. The default is 700 milliseconds. 7 Enter the volume adjustment for all incoming speech on analog...
Page 315
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 261 Note:The incoming speech volume value is set on a per card basis for digital circuit cards, versus on a system wide basis for analog circuit cards.8 Enter the volume adjustment for all outgoing speech played on the circuit card in the Outgoing Speech Volume: field. Valid values range from 0–32000. The default is 707. The value in this field and its...
Page 316
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 262 Note:For blind transfers to work with the Line Side DEFINITY protocol, you must set the To Initiate Transfer: field to “FW”, and the To Complete Transfer: field to “H,” in the Analog Interface window. See Set Analog Interfaces Parameters on page 238 for more information. U.S. and Canada: Intelligent transfer (full call classification analysis –...
Page 317
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 263 12 (LSE1 only) Enter the 8-digit code generated when the channel is idle in the Idle Code: field. 13 (LSE1 only) Enter A-LAW or MU-LAW in the A-LAW or MU-LAW: field. 14 (LSE1 only) Enter Yes to enable the cyclical redundancy check error checking or No to disable the error checking in the CRC: field. 15 Press F3 (Save). The system saves the...
Page 318
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 264 Use the following procedure to change the Line Side DEFINITY parameters:1 Start at the Line Side DEFINITY menu (Figure 131 on page 256 ) and select The system displays the Change Parameters: Line Side DEFINITY window (Figure 133 on page 264 ). Figure 133. Change Parameters: Line Side DEFINITY Window> Change Parameters
Page 319
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 265 2 Enter the circuit card number in the Card Number: field, or press F2 (Choices) to select from a menu. Initially, all fields are populated with the current values for the circuit card number entered. The Card Number: field is blank in Figure 133 on page 264 . After you enter the circuit card number, certain fields disappear depending on the...
Page 320
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 266 Display Line Side DEFINITY ParametersThe digital circuit card must first be assigned to the Line Side DEFINITY protocol to use this procedure. See Assign Line Side DEFINITY Protocol to Digital Circuit Cards on page 257 , for more information about making the initial assignment. Use the following procedure to display the Line Side DEFINITY parameters of a...