Page 321

5  
Switch Interface Administration  Digital Interfaces
Intuity™ CONVERSANT® System Version 7.0 Administration 
585-313-501 Issue 3 January 2000 267
Figure 134. Display Parameters:  Line Side DEFINITY Window
2  
Enter the circuit card number in the 
Card Number:
 field, or press 
F2
 
(Choices) to select from a menu.
The 
Card Number:
 field is blank in Figure 134 on page 267
. After you 
enter the circuit card number, certain fields disappear depending on the 
configuration of the selected circuit card;...

Page 322

5  
Switch Interface Administration  Digital Interfaces
Intuity™ CONVERSANT® System Version 7.0 Administration 
585-313-501 Issue 3 January 2000 268
The LSE1-specific fields are:~
Idle Code
~
A-LAW or MU-LAW
~
CRC
The LST1-specific field is:
~
CSU Distance
3  
Press 
F6
 (Cancel) to return to the Line Side DEFINITY menu.
Unassign Line Side DEFINITY Protocol to Digital Circuit CardsNote:Before attempting to make any assignment changes to circuit 
cards, they must be in the “manoos” state. See Equipment...

Page 323

5  
Switch Interface Administration  Digital Interfaces
Intuity™ CONVERSANT® System Version 7.0 Administration 
585-313-501 Issue 3 January 2000 269
Figure 135. Unassign Card:  Line Side DEFINITY Window
2  
Enter the circuit card number in the 
Card Number:
 field, or press 
F2
 
(Choices) to select from a menu.
The 
Card Number:
 field is blank in Figure 135 on page 269
. After you 
enter the circuit card number, certain fields disappear depending on the 
configuration of the selected circuit card;...

Page 324

5  
Switch Interface Administration  Digital Interfaces
Intuity™ CONVERSANT® System Version 7.0 Administration 
585-313-501 Issue 3 January 2000 270
The LST1-specific fields are:~
CSU Distance
3  
Press 
F3
 (Save).
The system removes the Line Side DEFINITY assignment from the 
selected circuit card.
4  
Press 
F6
 (Cancel) repeatedly to return to the Digital Interfaces menu.
Line Side Galaxy 
Protocol
The Line Side Galaxy protocol is supported on the Rockwell Galaxy switch for 
use with T1 digital...

Page 325

5  
Switch Interface Administration  Digital Interfaces
Intuity™ CONVERSANT® System Version 7.0 Administration 
585-313-501 Issue 3 January 2000 271
Figure 136. Line Side Galaxy Menu  Use the following procedures to assign/unassign the Line Side Galaxy 
protocol to digital circuit cards, and administer Galaxy switch interface 
parameters.Assign Line Side Galaxy Protocol to Digital Circuit CardsNote:Before a new protocol can be assigned to a circuit card, any 
existing protocol must first be “unassigned.”...

Page 326

5  
Switch Interface Administration  Digital Interfaces
Intuity™ CONVERSANT® System Version 7.0 Administration 
585-313-501 Issue 3 January 2000 272
Use the following procedure to assign the Line Side Galaxy protocol to a T1 
circuit card:1  
Start at the Line Side Galaxy menu (Figure 136 on page 271
) and select
The system displays the Assign Card: Line Side Galaxy window (Figure 
137 on page 273
).
> Assign Card 

Page 327

5  
Switch Interface Administration  Digital Interfaces
Intuity™ CONVERSANT® System Version 7.0 Administration 
585-313-501 Issue 3 January 2000 273
Figure 137. Assign Card:  Line Side Galaxy Window  2  
Enter the circuit card number in the 
Card Number:
 field, or press 
F2
 
(Choices) to select from a menu. Initially, all fields are populated with the 
default values for the circuit card number entered.
The 
Card Number:
 field is blank in Figure 137 on page 273
. After you 
enter the circuit card...

Page 328

5  
Switch Interface Administration  Digital Interfaces
Intuity™ CONVERSANT® System Version 7.0 Administration 
585-313-501 Issue 3 January 2000 274
3  
Enter Yes to enable or No to disable in the
 DTMF Muting:
 field, or press 
F2
 (Choices) to select from a menu. Yes is the default.
Enter Yes to use dial-tone multifrequency (DTMF) muting to reduce false 
DTMF recognitions that sometimes result from the network echoing back 
sounds that the voice system falsely recognizes as touch tones. Yes then 
turns...

Page 329

5  
Switch Interface Administration  Digital Interfaces
Intuity™ CONVERSANT® System Version 7.0 Administration 
585-313-501 Issue 3 January 2000 275
Any adjustment occurs before the system processes the incoming speech 
for coding it later for playback.  The value in the 
Incoming Speech 
Volume:
 field represents a gain applied to the speech input using a  
logarithmic scale.  A value of 1000 equals no gain; that is, the input is 
coded at the same level as it is received.  Multiplying by 1.414 (the...

Page 330

5  
Switch Interface Administration  Digital Interfaces
Intuity™ CONVERSANT® System Version 7.0 Administration 
585-313-501 Issue 3 January 2000 276
8  
(Optional) Enter the outgoing volume of speech in the 
Outgoing Text 
Volume:
 field. Valid values are 0–32000 (-30 to +30 dB). The default 
value is 1000.
Note:The optional Text-to-Speech feature package must be installed on 
your system for this field to be visible.
9  
Enter the time from when the flash ends until control is returned to the 
script in...