Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies Intuity CONVERSANT System Version 7.0 Guide
Lucent Technologies Intuity CONVERSANT System Version 7.0 Guide
Here you can view all the pages of manual Lucent Technologies Intuity CONVERSANT System Version 7.0 Guide. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 361
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 307 3 Enter Yes to enable or No to disable in the DTMF Muting: field, or press F2 (Choices) to select from a menu. Yes is the default. Enter Yes to use dual-tone multifrequency (DTMF) muting to reduce false DTMF recognitions that sometimes result from the network echoing back sounds that the voice system falsely recognizes as touch tones. Enter No when...
Page 362
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 308 8 Enter addressing to be used with outgoing calls, either DTMF, MF, or DECADIC in the Outgoing Addressing Type: field. The default value is DTMF. 9 Enter addressing to be used with incoming calls, either DTMF, MF, or DECADIC in the Incoming Addressing Type: field. The default value is DTMF. 10 Enter signaling to be used with outgoing calls,...
Page 363
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 309 To decrease the incoming speech volume, multiply by 0.707 to approximately half the value or decrease it by 3 dB. Therefore, a value of 707 in the field reduces the volume by half, 500 by half a second time, etc. See Table 33 on page 338 for the relationship between the volume number and the actual change in volume expressed in decibels. Note:The...
Page 364
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 310 Change T1 A/B Robbed-bit E&M Parameters The circuit card must first be assigned to the T1 A/B Robbed-bit E&M protocol to use this procedure. See Assign T1 A/B Robbed-bit E&M to Digital Circuit Cards on page 304 for more information about making the initial assignment. Note:Before attempting to make any assignment changes to circuit cards, they must be...
Page 365
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 311 Figure 153. Change Parameters: T1 A/B Robbed-bit E&M Window 2 Enter the circuit card number in the Card Number: field, or press F2 (Choices) to select from a menu. Initially, all fields are populated with the default values for the circuit card number entered. The Card Number: field is blank in Figure 153 on page 311 . After you enter the circuit...
Page 366
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 312 3 Change any of the parameters as described in Assign T1 A/B Robbed-bit E&M to Digital Circuit Cards on page 304 . 4 Press F3 (Save). The system changes the protocol parameters on the selected circuit card. Display T1 A/B Robbed-bit E&M Parameters The circuit card must first be assigned to the T1 A/B Robbed-bit E&M protocol to use this procedure....
Page 367
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 313 Figure 154. Display Parameters: T1 A/B Robbed-bit E&M Window 2 Enter the circuit card number in the Card Number: field, or press F2 (Choices) to select from a menu. Initially, all fields are populated with the default values for the circuit card number entered. The Card Number: field is blank in Figure 154 on page 313 . After you enter the...
Page 368
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 314 The system displays the parameter values for the selected circuit card. 3 Press F6 (Cancel) to return to the T1 A/B Robbed-bit E&M menu. Unassign T1 A/B Robbed-bit E&M to Digital Circuit Cards Note:Before attempting to make any assignment changes to circuit cards, they must be in the MANOOS state. See Equipment State on page 150 in Chapter 3,...
Page 369
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 315 Figure 155. Unassign Card: T1 A/B Robbed-bit E&M Screen 2 Enter the circuit card number in the Card Number: field, or press F2 (Choices) to select from a menu. The system displays the current parameter values for the selected circuit card. 3 Press F3 (Save). The system removes the T1 A/B Robbed-bit E&M assignment from the selected circuit...
Page 370
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 316 ISDN-PRI Layer 1 ProtocolAccess the ISDN- PRI Layer 1 Menu Note:All selected options must match the corresponding options on the network switch, otherwise service problems can occur. Use the following procedure to access the ISDN-Primary Rate Interface (ISDN-PRI) Layer 1 menu:1 Start at the Digital Interfaces menu (Figure 129 on page 248 ) and select...