Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies Intuity CONVERSANT System Version 7.0 Guide
Lucent Technologies Intuity CONVERSANT System Version 7.0 Guide
Here you can view all the pages of manual Lucent Technologies Intuity CONVERSANT System Version 7.0 Guide. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 381
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 327 The list below shows the LSE1-specific fields:~ Idle Code ~ A-LAW or MU-LAW ~ CRC The list below shows the LST1-specific fields: ~ CSU Distance 3 Change any of the parameters as described in Assign an ISDN-PRI Layer 1 to Digital Circuit Cards on page 317 . 4 Press F3 (Save). The system changes the specified parameters for the selected circuit card....
Page 382
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 328 Use the following procedure to display the ISDN-PRI Layer 1 parameters:1 Start at the ISDN-PRI Layer 1 menu (Figure 156 on page 316 ) and select The system displays the Display Parameters: ISDN-PRI Layer 1 window (Figure 159 on page 328 ). Figure 159. Display Parameters: ISDN-PRI Layer 1 Window> Display Parameters
Page 383
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 329 2 Enter the circuit card number in the Card Number: field, or press F2 (Choices) to select from a menu. Initially, all fields are populated with the default values for the circuit card number entered. The Card Number: field is blank in Figure 159 on page 328 . After you enter the circuit card number, certain fields disappear depending on the...
Page 384
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 330 Unassign ISDN-PRI Layer 1 Card Note:Before attempting to make any assignment changes to circuit cards, they must be in the MANOOS state. See Equipment State on page 150 in Chapter 3, Voice System Administration , for additional information. If you change digital protocol assignments on the voice system, you must make the change on the switch as...
Page 385
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 331 Figure 160. Unassign Card: ISDN-PRI Layer 1 Window 2 Enter the circuit card number in the Card Number: field, or press F2 (Choices) to select from a menu. The system displays the current parameter values for the selected circuit card. 3 Press F3 (Save). The system removes the ISDN-PRI Layer 1 assignment from the selected circuit card. 4...
Page 386
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 332 E1 PRI Using the ACULAB Protocol Converter With the use of the ACULAB protocol converter card to support the United Kingdom’s DASS2 and DPNSS protocols, it is no longer necessary to assign an SP card to PRI for use with the E1 PRI protocol. The D-channel processing can now be performed on the AYC21 circuit card leaving the SP circuit card available for...
Page 387
5 Switch Interface Administration Digital Interfaces Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 333 Figure 161. Aculab Converter Card ConnectionsWhen using the Aculab protocol converter, it is necessary to set the FLAGS and NPI_TOA parameters in the /vs/data/pri/pri.rc file as described in the /vs/man/cat4/pri.rc.4 manual page. This administration must be performed manually. RX TX RX TX RX TX B A C K P L A N E Network ACULAB converter card AYC21 EI...
Page 388
5 Switch Interface Administration T1 Configuration for the Intuity CONVERSANT System Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 334 T1 Configuration for the Intuity CONVERSANT System for 4ESS Applications The following options should be used when connecting an Intuity CONVERSANT system to a 4ESS via an E1/T1 line when using the E&M protocol. Note:Some parameters on the switch side may require that you stop and restart the voice system once you have made...
Page 389
5 Switch Interface Administration T1 Configuration for the Intuity CONVERSANT System Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 335 • E1/T1 E&M Fixed Parameters:~ Framing/Line Coding: D4/ZCS• Signaling: A or AB Robbed-bit E&M protocol • Incoming/Outgoing Start Dialing: wink/wink • Incoming/Outgoing Addressing: DTMF/DTMF ~ Timing Source: Looped Timed • 4ESS Options The following information is requested by AT&T when provisioning the 4ESS for a E1/T1...
Page 390
5 Switch Interface Administration T1 Configuration for the Intuity CONVERSANT System Intuity™ CONVERSANT® System Version 7.0 Administration 585-313-501 Issue 3 January 2000 336 • ADDRESS SIGNALING (TYPE OF PULSING) TO CPE: DTMF(TT) • ADDRESS SIGNALING TT DELAY: 70MS • ADDRESS SIGNALING from CPE: DTMF(TT) • START DIAL SIGNALING PROVIDED BY CPE: WK • START DIAL SIGNALING PROVIDED TO CPE: WK (senderized operation) • CPE DOES NOT SUPPORT DIFFERENT SIGNALING BIDIRECTIONALLY • NUMBER OF DIGITS OUTPULSED...