Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 401

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-139 Add MCC Port Carriers 
6
Figure 6-55. TDM/LAN Bus Connections for Critical-Reliability EPN
ICCB
PORT CARRIER
PORT CARRIER
ICCA
SLOT 02
ICCBICCACABLES A AND B
H600-204 G1
B
EXPANSIONCONTROL CARRIER
SLOT 21
PORT CARRIER
SLOT 21
REAR VIEW PORT CARRIER SLOT 21(ZAHF4)
C
SLOT 21
D
E
J58890BB
J58890BB SEE NOTE
SEE NOTE
SEE NOTE
SEE NOTE TDM/LAN BUS...

Page 402

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-140 Add MCC Port Carriers 
6
Table 6-11. TDM/LAN Cable Connections
“J” Number Carrier Type LHS Slot RHS Slot
J58890B-1 Port 21 02
J58890B-2 Port 21 01
J58890B-3 Port 21 01
J58890AP PPN Control “A” or “B” 20 03
J58890AF AC EPN Control “ A” 21 02
J58890AF DC EPN Control “ A” 21 02 

Page 403

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-141 DEFINITY AUDIX Power Procedures 
6
DEFINITY AUDIX Power Procedures
Power Down the AUDIX System
A yellow c aution stic ker on the system’s power unit notifies tec hnic ians to shut 
d own the DEFINITY AUDIX System p rior to p owering  d own the system.
1. Log  into the AUDIX System as craft
. 
2. Type reset system shutdown
. Press 
En te r onc e....

Page 404

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-142 Installing an Integrated Channel Service Unit (ICSU) Module 
6
Installing an Integrated Channel
Service Unit (ICSU) Module
The integ rated c hannel servic e unit (ICSU) is a c omb ination of a 120A CSU 
mod ule integ rated  with a DS1 c irc uit p ac k. Use this d evic e with the 700A DS1 
loop b ac k jac k when testing  the DS1 sp an. 
Checking...

Page 405

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-143 Installing an Integrated Channel Service Unit (ICSU) Module 
6
Figure 6-56. 120A Channel Service Unit Module
!CAUTION:
Do not p lug  the 120A into any c irc uit p ac k other than a TN474F or TN777E 
or later release/vintag e. Do not c onnec t the 120A to any interfac e other than 
a network smart jac k.
Be sure the DS1 c irc uit p ac k is set for...

Page 406

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-144 Installing an Integrated Channel Service Unit (ICSU) Module 
6
4. Sec ure the 4C retainer around  the 120A.
5. Attac h the sup p lied  H600-383 c able to the 120A and to the network smart 
jac k. 
This c ab le is d irec tional. To determine the end  that c onnec ts to the 120A, 
p erform a c ontinuity test b etween pins 3 and  7. The end  with...

Page 407

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-145 Installing an Integrated Channel Service Unit (ICSU) Module 
6
Table 6-12 p rovid es the H600-383 c ab le p inouts. Table 6-13 p rovid es the c ab le 
leng ths for eac h c ab le g roup  numb er.
Table 6-12. H600-383 cable Pin Assignments
Pin ColorChannel Service 
Unit DesignationNetwork 
Designation Function
1BK Line in 0 R1 RCV
2 Y Line in 1 T1...

Page 408

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-146 Installing a 3150/3170 Channel Service Unit 
6
Installing a 3150/3170 
Channel Service Unit
1. Install the CSU as shown in Figure 6-57. For some installations (suc h as a 
DS1 c onverter), use a Y-c ab le to c onnec t the DEFINITY System to the 
q uad  c ab le. Table 6-14
 shows the Y-c ab le lengths. Be sure to lab el all 
cables. 
Figure 6-57...

Page 409

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-147 Installing a 3150/3170 Channel Service Unit 
6
Figure 6-58. DS1 Converter Connections Using Double-Headed cable
1. Port c arrier
2. DS1 c onverter c onnec tor
3. 50-p air female c onnec tor to DEFINITY System
4. 14-Inc h (35.57 c m) “ Y”  c ab le5. 50-Pin Male/50-p in female d ouble-headed   
c onnec tor c ab le
6. Quad c ab le (with 50-pin male...

Page 410

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-148 Installing a 3150/3170 Channel Service Unit 
6 
Start reading Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual