Page 431
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Managing data calls 407 Data Call Setup 15 3. On the Modem Pool Group screen, administer the Circuit Pack Assignments field. Refer to ‘‘ Modem Pool Group’’ on page 829 for more information. Depending on the hardware used, assign ports to the following: nData modules n7400D-series or CALLMASTER digital telephones n7500D-series telephones with asynchronous data module (ADM) nAnalog modems (port is assigned using 2500...
Page 432
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Managing data calls 408 Data Call Setup 15 Examples of dialing are: nDIAL: 3478 nDIAL: 9+(201) 555-1212 nDIAL: 8, 555-2368 nDIAL: 9+555-2368+%9999+123 (remote access) The following call-progress messages and their meanings are provided for DCP and ISDN-BRI modules. Table 5. Call-progress messages Message Application Meaning DIAL: DCP Equivalent to dial tone. Enter the desired number or FAC followed by Enter. CMD BRI...
Page 433
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Managing data calls 409 Data Call Setup 15 FORWARDED DCP, BRI Equivalent to redirection-notification signal. Called terminal activates Call Forwarding and receives a call, and call is forwarded. INCOMING CALLDCP, BRI Equivalent to ringing. INVALID ADDRESSDCP Entered name is not in alphanumeric-dialing table. WRONG ADDRESSBRI Entered name is not in alphanumeric-dialing table. PLEASE ANS- DCP, BRI Originating...
Page 434
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Managing data calls 410 Data Call Setup 15 DCP data modules Data-terminal dialing DCP data-terminal dialing allows a user to set up and disconnect data calls directly from a data terminal as follows. 1. At the DIAL: prompt, the user types the data number. The message RINGING displays. 2. If the call is queued, the message WAIT, XX IN QUEUE displays. The queue position XX updates as the call moves up in queue. 3. To...
Page 435
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Managing data calls 411 Data Call Setup 15 nData Call Preindication A user, before dialing a data endpoint, can reserve the associated data module by pressing the data-extension button. This ensures that a conversion resource, if needed, and the data module are reserved for the call. Use of Data Call Preindication before 1-button transfer to data is recommended for data calls that use toll-network facilities. Data Call...
Page 436
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Managing data calls 412 Data Call Setup 15 In a passive-bus multipoint configuration, the system supports two BRI endpoints per port, thus doubling the capacity of the BRI circuit pack. When you change the configuration of a BRI from point-to-point to multipoint, the original endpoint does not need to reinitialize. Only endpoints that support service profile identifier (SPID) initialization can be administered in a...
Page 437
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Managing data calls 413 Default Dialing 15 nWorld-Class Tone Detection Multiple-line data-terminal dialing is supported if the administered level of tone detection is precise. You can administer tone-detection options. The message that Data Call Setup sends to users varies according to the option. If the option is not set to precise, and a data call is set up over an analog trunk, messages describing the status of the...
Page 438
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Managing data calls 414 Alphanumeric Dialing 15 Alphanumeric Dialing Alphanumeric Dialing enhances data-terminal dialing by allowing users to place data calls by entering an alphanumeric name rather than a long string of numbers. For example, a user could type 9+1-800-telefon instead of 9+1-800-835-3366 to make a call. Users need to remember only the alpha-name of the far-end terminating point. Alphanumeric Dialing...
Page 439
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Managing data calls 415 Data Hotline 15 Data Hotline Data Hotline provides for automatic-nondial placement of a data call preassigned to an endpoint when the originating switch goes off-hook. Use for security purposes. Administering Data Hotline 1. You can use an abbreviated dialing list for your default ID. Refer to ‘‘ Abbreviated Dialing’’ on page 1139 for more information. 2. On the Station screen, administer the...
Page 440
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Managing data calls 416 Data Privacy 15 Data Privacy Data Privacy protects analog data calls from being disturbed by any of the system’s overriding or ringing features. Administering Data Privacy 1. Choose either of the following: nOn the Feature Access Code screen, administer the Data Privacy Access Code field. Refer to ‘‘ Feature Access Code’’ on page 633 for more information. nOn the Class of Service screen,...