Managing data calls 
407 Data Call Setup 
15
3. On the Modem Pool Group screen, administer the Circuit Pack 
Assignments field. Refer to ‘‘
Modem Pool Group’’ on page 829 for more 
information.
Depending on the hardware used, assign ports to the following:
nData modules
n7400D-series or CALLMASTER digital telephones
n7500D-series telephones with asynchronous data module (ADM)
nAnalog modems (port is assigned using 2500...

Page 432

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Managing data calls 
408 Data Call Setup 
15
Examples of dialing are:
nDIAL: 3478
nDIAL: 9+(201) 555-1212
nDIAL: 8, 555-2368
nDIAL: 9+555-2368+%9999+123 (remote access)
The following call-progress messages and their meanings are provided for DCP 
and ISDN-BRI modules.
Table 5. Call-progress messages
Message Application Meaning
DIAL: DCP Equivalent to dial tone. Enter the desired 
number or FAC followed by Enter.
CMD BRI...

Page 433

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Managing data calls 
409 Data Call Setup 
15
FORWARDED DCP, BRI Equivalent to redirection-notification 
signal. Called terminal activates Call 
Forwarding and receives a call, and call 
is forwarded.
INCOMING 
CALLDCP, BRI Equivalent to ringing.
INVALID 
ADDRESSDCP Entered name is not in 
alphanumeric-dialing table.
WRONG 
ADDRESSBRI Entered name is not in 
alphanumeric-dialing table.
PLEASE ANS- DCP, BRI Originating...

Page 434

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Managing data calls 
410 Data Call Setup 
15
DCP data modules
Data-terminal dialing 
DCP data-terminal dialing allows a user to set up and disconnect data calls 
directly from a data terminal as follows.
1. At the DIAL: prompt, the user types the data number. The message 
RINGING displays.
2. If the call is queued, the message WAIT, XX IN QUEUE displays. The 
queue position XX updates as the call moves up in queue.
3. To...

Page 435

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Managing data calls 
411 Data Call Setup 
15
nData Call Preindication
A user, before dialing a data endpoint, can reserve the associated data 
module by pressing the data-extension button. This ensures that a 
conversion resource, if needed, and the data module are reserved for the 
call. Use of Data Call Preindication before 1-button transfer to data is 
recommended for data calls that use toll-network facilities. Data Call...

Page 436

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Managing data calls 
412 Data Call Setup 
15
In a passive-bus multipoint configuration, the system supports two BRI endpoints 
per port, thus doubling the capacity of the BRI circuit pack. When you change the 
configuration of a BRI from point-to-point to multipoint, the original endpoint 
does not need to reinitialize. Only endpoints that support service profile identifier 
(SPID) initialization can be administered in a...

Page 437

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Managing data calls 
413 Default Dialing 
15
nWorld-Class Tone Detection
Multiple-line data-terminal dialing is supported if the administered level of 
tone detection is precise. You can administer tone-detection options. The 
message that Data Call Setup sends to users varies according to the option.
If the option is not set to precise, and a data call is set up over an analog 
trunk, messages describing the status of the...

Page 438

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Managing data calls 
414 Alphanumeric Dialing 
15
Alphanumeric Dialing
Alphanumeric Dialing enhances data-terminal dialing by allowing users to place 
data calls by entering an alphanumeric name rather than a long string of numbers.
For example, a user could type 9+1-800-telefon instead of 9+1-800-835-3366 to 
make a call. Users need to remember only the alpha-name of the far-end 
terminating point.
Alphanumeric Dialing...

Page 439

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Managing data calls 
415 Data Hotline 
15
Data Hotline
Data Hotline provides for automatic-nondial placement of a data call preassigned 
to an endpoint when the originating switch goes off-hook. Use for security 
purposes.
Administering Data Hotline
1. You can use an abbreviated dialing list for your default ID. Refer to 
‘‘
Abbreviated Dialing’’ on page 1139 for more information.
2. On the Station screen, administer the...

Page 440

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Managing data calls 
416 Data Privacy 
15
Data Privacy
Data Privacy protects analog data calls from being disturbed by any of the 
system’s overriding or ringing features.
Administering Data Privacy
1. Choose either of the following:
nOn the Feature Access Code screen, administer the Data Privacy 
Access Code field. Refer to ‘‘
Feature Access Code’’ on page 633 for 
more information.
nOn the Class of Service screen,...