Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual
Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual
Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 221
Event Reports Issue 6 June 1997 5-37 Trunk Seized Event Report Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke...
Page 222
Byte Level Messages 5-38Issue 6 June 1997 Call Control Capability Group Call Control: REGister Messages Sent by the Adjunct A REGister message initiates an association on a CRV. All REGister messages have the Protocol Discriminator and the CRV followed by a REG type = 0x64.
Page 223
Call Control Capability Group Issue 6 June 1997 5-39 Third Party Make Call Request (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? assigned value Second CRV Byte0x? assigned value Message Type 0x64 REGister Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility 0x?? computed length Q.932 Supplementary Service 0x91 component type tag = invoke 0xa1 INVOKE component component length 0x?? computed length...
Page 224
Byte Level Messages 5-40Issue 6 June 1997 Third Party Make Call Request — (continued) Byte Description Byte Value Comments * The 1st to N-1 ASCII digits0x?? 0x30 through 0x39 Ext bit | last ASCII digit0x?? 0xb0 through 0xb9 The Domain IE 0x49 present for direct agent call The length of the Domain IE 0x? The Domain type = ACD Split0x81 ACD split * The 1st to N-1 ASCII digits0x?? 0x30 through 0x39 Ext bit | last ASCII digit0x?? 0xb0 through 0xb9 Call Options IE0x4b Length of Call Option IE0x02 Option =...
Page 225
Call Control Capability Group Issue 6 June 1997 5-41 The switch supports only certain combinations of call options. Not all optional bytes can be present. Appendix A describes how the switch validates the various optional Information Elements that may be present in this request and how the switch determines which of the internal call types it will attempt to establish. Service Circuit IE0x4e Length of Service Circuit IE0x01 Tone Detection/Call Classification0x81 Third Party Make Call Request —...
Page 226
Byte Level Messages 5-42Issue 6 June 1997 Third Party Take Control Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? assigned value Second CRV Byte0x? assigned value Message Type 0x64 REGister Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility 0x?? computed length Q.932 Supplementary Service 0x91 component type tag = invoke 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form...
Page 227
Call Control Capability Group Issue 6 June 1997 5-43 Call Control: REGister Messages Sent by the switch None for Call Control. Call Control: FACility Messages Sent by the Adjunct A FACility message is used to initiate an action with an existing association. All FACility messages have the Protocol Discriminator and the CRV followed by a FAC type = 0x62. The Call Control message encodings located in this section are: nThird Party Clear Call Request nThird Party Selective Drop Request nThird Party...
Page 228
Byte Level Messages 5-44Issue 6 June 1997 Third Party Clear Call Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag...
Page 229
Call Control Capability Group Issue 6 June 1997 5-45 Third Party Selective Drop Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke...
Page 230
Byte Level Messages 5-46Issue 6 June 1997 Third Party Selective Hold Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag...