Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 211

Event Reports
Issue 6  June 1997
5-27
Entered Digits Event Report
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Octet 0x?
Second CRV Octet0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke identifier tag 0x02...

Page 212

Byte Level Messages
5-28Issue 6  June 1997 
Hold Event Report
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke identifier tag 0x02
invoke...

Page 213

Event Reports
Issue 6  June 1997
5-29
Login Event Report — 
Domain (ACD Split/Skill) Control Association
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Octet 0x?
Second CRV Octet0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component...

Page 214

Byte Level Messages
5-30Issue 6  June 1997 
NOTE:
The last Domain IE listed (Logical Extension) is present only if Expert Agent Selection 
is used.Login Event Report — Domain (ACD Split/Skill) Control Association
(continued)
Byte DescriptionByte 
Value Comments
The Domain IE 0x49 Physical Extension
The length of the Domain IE  0x?
The Domain type = Extension 0x83
* The 1st to N-1 ASCII digits 0x?? 0x30 through 0x39
Ext bit | last ASCII digit  0x?? 0xb0 through 0xb9
The Domain IE 0x49
The length of the...

Page 215

Event Reports
Issue 6  June 1997
5-31
Logout Event Report —
Domain (ACD Split/Skill) Control Association
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component...

Page 216

Byte Level Messages
5-32Issue 6  June 1997 
 
1.The Domain IE listed for Logical Extension is present only if Expert Agent Selection
is used.
2.The reason codes Domain IE is present only if the System-Parameter Features field,
Logout Reason Codes, is “forced” or “requested” and the agent logs out with a valid
reason code (1-9).Logout Event Report — Domain (ACD Split/Skill) Control Association
(continued)
Byte Description Byte Value Comments
The Domain IE0x49 Logical Extension
Note1
The length of the...

Page 217

Event Reports
Issue 6  June 1997
5-33
Queued Event Report
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke identifier...

Page 218

Byte Level Messages
5-34Issue 6  June 1997 
NOTE:
The value takes up two bytes if the value is greater than 127. The high order bits are 
first followed by 0x80 | low order bits.Queued Event Report — (continued)
Byte Description Byte Value Comments
The Specific Event IE 0x47
The length of the Specific Event IE 0x01
Event value = Queued  0x87
The Domain IE  0x49
The length of the Domain IE  0x?
The Domain type = ACD Split 0x81 ACD split
* The first to N-1 extension digits 0x?? 0x30 thru 0x39
The last...

Page 219

Event Reports
Issue 6  June 1997
5-35
Reconnected Event Report
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke identifier tag 0x02
invoke...

Page 220

Byte Level Messages
5-36Issue 6  June 1997 
Reorder/Denial Event Report
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke identifier tag 0x02...
Start reading Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

All Lucent Technologies manuals