Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 251
Call Control Capability Group Issue 6 June 1997 5-67 Call Control: RELease COMplete Messages Sent by Both the switch and the Adjunct A RELease COMplete message terminates an association on an existing CRV. All RELease COMplete messages have the Protocol Discriminator and the CRV followed by a REL COM type = 0x5a. Call Control: Normal Clearing Terminates Call Control Association Call Control: A Message is Not Understood — Association Aborted Byte Description Byte Value Comments Protocol Discriminator...
Page 252
Byte Level Messages 5-68Issue 6 June 1997 Call Control: Endpoint Rejects an Invalid/Protocol Violation FIE — Terminates Association Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa4 REJECT component length 0x?? computed length invoke...
Page 253
Call Control Capability Group Issue 6 June 1997 5-69 Call Control: Endpoint Aborts an Association NOTE: The switch always supplies a cause value when it aborts an association; the adjunct may optionally supply a cause value. Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary...
Page 254
Byte Level Messages 5-70Issue 6 June 1997 Domain Control Capability Group Domain Control: REGister Messages Sent by the Adjunct A REGister message initiates an association on a CRV. All REGister messages have the Protocol Discriminator and the CRV followed by a REG type = 0x64. Domain Control (Station/ACD Split) Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? assigned value Second CRV Byte0x? assigned value Message Type 0x64...
Page 255
Domain Control Capability Group Issue 6 June 1997 5-71 Domain Control: REGister Messages Sent by the switch None for Domain Control. Domain Control: FACility Messages Sent by the Adjunct A FACility message is used to initiate an action with an existing association. All FACility messages have the Protocol Discriminator and the CRV followed by a FAC type = 0x62. The message encodings located in this section are: nThird Party Selective Drop Request nThird...
Page 256
Byte Level Messages 5-72Issue 6 June 1997 Third Party (Domain) Selective Drop Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke...
Page 257
Domain Control Capability Group Issue 6 June 1997 5-73 Third Party (Domain) Selective Hold Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127)...
Page 258
Byte Level Messages 5-74Issue 6 June 1997 Third Party (Domain) Reconnect Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier...
Page 259
Domain Control Capability Group Issue 6 June 1997 5-75 Third Party (Domain) Merge Request NOTE: The call_id for the held call, when present, must follow the call_id for the active call. Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE...
Page 260
Byte Level Messages 5-76Issue 6 June 1997 Third Party (Domain) Answer Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier...