Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 261
Domain Control Capability Group Issue 6 June 1997 5-77 Third Party Auto Dial Request for an Extension (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component...
Page 262
Byte Level Messages 5-78Issue 6 June 1997 NOTE: Use of the “return-ack” option is not recommended.Third Party Auto Dial Request for an Extension — (continued) Ext bit | last ASCII digit0x?? 0xb0 through 0xb9 Call Options IE0x4b Length of Call Option IE0x01 Option = priority call0x83 Call Options IE0x4b Length of Call Option IE0x01 Option = return ack flag0x8c
Page 263
Domain Control Capability Group Issue 6 June 1997 5-79 Third Party (Domain) Relinquish Control Request The adjunct invokes Relinquish control to terminate a Domain (Station/ACD Split) Control Request. Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag...
Page 264
Byte Level Messages 5-80Issue 6 June 1997 Third Party (Domain) Send DTMF Digits Request The adjunct invokes Send_DTMF_digits to request that DTMF tones be sent on a call to selected parties. (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91...
Page 265
Domain Control Capability Group Issue 6 June 1997 5-81 NOTE: The Party ID list can have up to five Party IDs.Third Party (Domain) Send DTMF Digits Request — (continued) Byte Description Byte Value Comments User Entered Code IE 0x02 User Entered Digit(s) Length of IE 0x?? calculated length Type 0x91 Customer-provided collected data indicator 0xc0 Already Collected * first n-1 digits 0x?? ACSII 0x30-0x39, 0x23(#), 0x2a(*) * last (nth) digit 0x?? ACSII 0xb0-0xb9, 0xa3(#), 0xaa(*) Call Options IE0x4b...
Page 266
Byte Level Messages 5-82Issue 6 June 1997 Redirect Call (Domain) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Octet 0x? Second CRV Octet0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02...
Page 267
Domain Control Capability Group Issue 6 June 1997 5-83 Domain Control: FACility Messages Sent by the switch A FACility message is used to initiate an action within an existing association on an active CRV. All FACility messages have the Protocol Discriminator and the CRV followed by a FAC type = 0x62.
Page 268
Byte Level Messages 5-84Issue 6 June 1997 Acknowledgment of Domain (Station) Control Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa2 RETURN RESULT component component length 0x?? computed length component length0x?? long form (length >...
Page 269
Domain Control Capability Group Issue 6 June 1997 5-85 NOTES: All bytes of this message from the sequence tag forward are present if, and only if, there are calls at the domain-controlled station. The presence of such calls results in parameters (call identity, party identity, and state) in this return result component. A return result component only contains a sequence tag and operation value when parameters are present. There is an association of the Nth call ID, party ID, and specific event....
Page 270
Byte Level Messages 5-86Issue 6 June 1997 Acknowledgment of Third Party Auto Dial Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke...