Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 231
Call Control Capability Group Issue 6 June 1997 5-47 Third Party Reconnect Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke...
Page 232
Byte Level Messages 5-48Issue 6 June 1997 Third Party Merge Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02...
Page 233
Call Control Capability Group Issue 6 June 1997 5-49 Third Party Relinquish Control Request The adjunct invokes Relinquish_control to terminate a call control association. Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component...
Page 234
Byte Level Messages 5-50Issue 6 June 1997 Third Party Listen Disconnect Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier...
Page 235
Call Control Capability Group Issue 6 June 1997 5-51 Third Party Listen Reconnect Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke...
Page 236
Byte Level Messages 5-52Issue 6 June 1997 Third Party Send DTMF Digits Request The adjunct invokes Send_DTMF_digits to request that DTMF tones be sent on a call to selected parties. (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type...
Page 237
Call Control Capability Group Issue 6 June 1997 5-53 NOTE: The first Party ID on the list is the tone “sender.” The Party ID list may optionally contain up to five additional members (who will hear the tones) on a Call Control Association Send DTMF request.Third Party Send DTMF Digits Request — (continued) Byte Description Byte Value Comments Call Options IE0x4b Length of Call Option IE0x02 Option = tone duration0x8a Value = tone duration0x8X seconds = value * 0.01 Call Options IE0x4b Length of Call...
Page 238
Byte Level Messages 5-54Issue 6 June 1997 Redirect Call Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Octet 0x? Second CRV Octet0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke...
Page 239
Call Control Capability Group Issue 6 June 1997 5-55 Call Control: FACility Messages Sent by the switch A FACility message is used to initiate an action within an existing association on an active CRV. All FACility messages have the Protocol Discriminator and the CRV followed by a FAC type = 0x62. Acknowledgment of Third Party Make Call Request (Continued on next page) 1. The Connected Number IE is only sent in Third Party Make Call ACKnowledgements for EAS. It is not sent for non-EAS (physical...
Page 240
Byte Level Messages 5-56Issue 6 June 1997 Acknowledgment of Third Party Make Call Request — (continued) Byte Description Byte Value Comments Length of Call identity 0x02 computed value * Call identifier (2 bytes) 0x?? switch-assigned value Locking Shift to Code Set 6 0x96 The Party Identifier IE 0x44 Length of the IE 0x01 or 0x02 Ext bit | Party ID 0x?? Ext bit | Party ID (second byte)0x??