Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 201
Event Reports Issue 6 June 1997 5-17 Call Redirected Event Report Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke...
Page 202
Byte Level Messages 5-18Issue 6 June 1997 Call Transferred Event Report (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127)...
Page 203
Event Reports Issue 6 June 1997 5-19 NOTES: The Call Identity IE containing the “other” call ID before the transfer operation must precede the Call Identity IE that contains the “resulting” call ID after the transfer operation. There must be the same number of Party ID IEs, Old Party ID IEs, and Connected Number IEs. The Nth Party ID IE and the Nth Old Party ID IE correspond to the Nth Connected Number IE (and thereby associate an extension with that party). To preserve a 1:1 correspondence, if the...
Page 204
Byte Level Messages 5-20Issue 6 June 1997 Charging Event Report (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Octet 0x? Second CRV Octet 0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length 0x?? long form (length > 127)...
Page 205
Event Reports Issue 6 June 1997 5-21 Charging Event Report — (continued) Byte Description Byte Value Comments Called Party Number IE 0x70 length of Called Party Number IE 0x?? computed length Address type & numbering plan 0x?? 0x80 * Address digits 0x?? 0x30 through 0x39, 0x23 (#), 0x2a (*) Locking Shift to Code 6 0x96 Trunk Identification IE 0x0a Outgoing trunk length of IE 0x?? computed length Direction 0x80 No direction * Trunk Group Number 0x?? binary-encoded value * Trunk Group Member Number 0x??...
Page 206
Byte Level Messages 5-22Issue 6 June 1997 Connected Event Report (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke...
Page 207
Event Reports Issue 6 June 1997 5-23 NOTE: The Calling Party Number IE and Trunk Identifier IE are mutually exclusive.Connected Event Report — (continued) Byte Description Byte Value Comments Address Type & numbering Plan Id0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 0xa1 *Address digits 0x?? 0x30 through 0x39, 0x23(#), 0x2a(*) Called Party Number IE 0x70 Length of Called Party Number 0x? computed length Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 0xa1 * Address digits 0x?? 0x30...
Page 208
Byte Level Messages 5-24Issue 6 June 1997 Cut-Through Event Report Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02...
Page 209
Event Reports Issue 6 June 1997 5-25 Disconnect/Drop Event Report (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke...
Page 210
Byte Level Messages 5-26Issue 6 June 1997 Disconnect/Drop Event Report — (continued) Byte Description Byte Value Comments Locking Shift to Code Set 6 0x96 The Party Identifier IE 0x44 Length of the IE 0x01 or 0x02 Ext bit | Party ID 0x?? Ext bit | Party ID (second byte)0x?? The Specific Event IE 0x47 The length of the Specific Event IE 0x01 Event value = Drop 0x84