Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 201

Event Reports
Issue 6  June 1997
5-17
Call Redirected Event Report
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke identifier tag 0x02
invoke...

Page 202

Byte Level Messages
5-18Issue 6  June 1997 
Call Transferred Event Report
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)...

Page 203

Event Reports
Issue 6  June 1997
5-19
NOTES:
The Call Identity IE containing the “other” call ID before the transfer operation 
must precede the Call Identity IE that contains the “resulting” call ID after the transfer 
operation.
There must be the same number of Party ID IEs, Old Party ID IEs, and Connected 
Number IEs.
The Nth Party ID IE and the Nth Old Party ID IE correspond to the Nth Connected 
Number IE (and thereby associate an extension with that party).
To preserve a 1:1 correspondence, if the...

Page 204

Byte Level Messages
5-20Issue 6  June 1997 
Charging Event Report
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Octet 0x?
Second CRV Octet 0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length 0x?? long form (length > 127)...

Page 205

Event Reports
Issue 6  June 1997
5-21
Charging Event Report — (continued)
Byte Description Byte Value Comments
Called Party Number IE 0x70
length of Called Party Number IE 0x?? computed length
Address type & numbering plan 0x?? 0x80
* Address digits 0x?? 0x30 through 0x39, 0x23 (#), 0x2a (*)
Locking Shift to Code 6 0x96
Trunk Identification IE 0x0a Outgoing trunk
length of IE 0x?? computed length
Direction 0x80 No direction
* Trunk Group Number 0x?? binary-encoded value
* Trunk Group Member Number 0x??...

Page 206

Byte Level Messages
5-22Issue 6  June 1997 
Connected Event Report
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke...

Page 207

Event Reports
Issue 6  June 1997
5-23
NOTE:
The Calling Party Number IE and Trunk Identifier IE are mutually exclusive.Connected Event Report — (continued)
Byte Description Byte Value Comments
Address Type & numbering Plan Id0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
0xa1
*Address digits 0x?? 0x30 through 0x39, 0x23(#), 
0x2a(*)
Called Party Number IE 0x70
Length of Called Party Number 0x? computed length
Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
0xa1
* Address digits 0x??  0x30...

Page 208

Byte Level Messages
5-24Issue 6  June 1997 
Cut-Through Event Report  
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke identifier tag 0x02...

Page 209

Event Reports
Issue 6  June 1997
5-25
Disconnect/Drop Event Report
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke...

Page 210

Byte Level Messages
5-26Issue 6  June 1997 
Disconnect/Drop Event Report — (continued)
Byte Description Byte Value Comments
Locking Shift to Code Set 6 0x96
The Party Identifier IE 0x44
Length of the IE  0x01 or 0x02
Ext bit | Party ID 0x??
Ext bit | Party ID (second byte)0x??
The Specific Event IE 0x47
The length of the Specific Event IE 0x01
Event value = Drop  0x84 
Start reading Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual