Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 191

Event Reports
Issue 6  June 1997
5-7
Answered Event Report — (continued)
Byte Description Byte Value Comments
Called Party Number IE 0x70
Length of Called Party Number 0x? computed length
Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
0xa1
* Address digits 0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
Locking Shift to Code Set 6 0x96
The Party Identifier IE 0x44
Length of the IE  0x01 or 0x02
Ext bit | Party ID 0x?? 
Ext bit | Party ID (second byte)0x??
The Specific Event IE 0x47
The...

Page 192

Byte Level Messages
5-8Issue 6  June 1997 
Busy/Unavailable Event Report
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke identifier tag 0x02...

Page 193

Event Reports
Issue 6  June 1997
5-9
Call Conferenced Event Report 
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke...

Page 194

Byte Level Messages
5-10Issue 6  June 1997 
NOTES:
The Call Identity IE containing the “other” call ID before the conference operation 
must precede the Call Identity IE that contains the “resulting” call ID after the 
conference operation.
There must be the same number of Party ID IEs, Old Party ID IEs, and Connected 
Number IEs.
The Nth Party ID IE and the Nth Old Party ID IE correspond to the Nth Connected 
Number IE (and thereby associate an extension with that party).
To preserve a 1:1...

Page 195

Event Reports
Issue 6  June 1997
5-11
Call Initiated Event Report
Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length > 127)
invoke identifier tag 0x02
invoke...

Page 196

Byte Level Messages
5-12Issue 6  June 1997 
Call Offered to Domain Event Report
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Byte 0x?
Second CRV Byte0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component length0x?? long form (length >...

Page 197

Event Reports
Issue 6  June 1997
5-13
Call Offered To Domain Event Report — (continued)
Byte Description Byte Value Comments
User-User IE 0x7e User-to-User information
length of user-user
0x?? computed length
protocol discriminator0x??
*user information0x??
Locking Shift to Code Set 60x96
Originating Line IE0x01
Length of OLI0x?? computed length
* II-Digits0x??
User Code IE0x02 User Entered Data IE
length of user data0x?? computed length
type of user data0x85 Call Prompter Data
collected data...

Page 198

Byte Level Messages
5-14Issue 6  June 1997 
NOTE:
The Calling Number IE and the Trunk Identification IE are mutually exclusive. One or 
the other is present.
Ext bit | Time Stamp - hours0x80 | 0x?? from PRI
Ext bit | Time Stamp - minutes0x80 | 0x?? from PRI
Ext bit | Time Stamp - seconds0x80 | 0x?? from PRI
*Ext bit | first n-1 ASCII characters 0x00 | 0x?? ASCII data from PRI
Ext bit | last ASCII character0x80 | 0x?? ASCII data from PRI Call Offered To Domain Event Report — (continued) 

Page 199

Event Reports
Issue 6  June 1997
5-15
Call Originated Event Report
NOTE:
Not supported in G3V4 or Release 5.
(Continued on next page) Byte Description Byte Value Comments
Protocol Discriminator 0x08 BRI
CRV Length 0x01 or 0x02
First CRV Octet 0x?
Second CRV Octet0x?
Message Type 0x62 FACility
Locking Shift to Code Set 6 0x96
Facility IE 0x1c
Length of Facility IE 0x?? computed length
Q.932 Supplementary Service 0x91
component type tag 0xa1 INVOKE component
component length 0x?? computed length
component...

Page 200

Byte Level Messages
5-16Issue 6  June 1997 
NOTE:
Not supported in G3V4 or Release 5.Call Originated Event Report — (continued)
Byte Description Byte Value Comments
* Call identifier (2 octets) 0x?? switch-assigned value
Calling Party Number 0x6c
Length of Calling Party IE 0x? computed length
Address Type & Numbering Plan ID 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, 
or 0xa1
* ASCII Address digits 0x??  0x30 through 0x39, 0x23 (#), 
0x2a (*)
Called Party Number IE 0x70
Length of Called Party Number 0x? computed...