Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 171

Codeset 6 Information Elements
Issue 6  June 1997
4-65
Resource Status
The Resource Status IE shown in Figure 4-35 gives status information about a 
resource.
.
Figure 4-35. Resource Status Information Element8 7 6 5 4 321
Resource status
0 0 0 0 0 011Byte1
Information element identifier
Length of resource status contents 2
1 Type of Resource 3
Ext
1 In Idle Maint Other Spare 4
Ext Use Busy Unavail
0/1 Count of Highest 5
Ext Order Status Shown
0/1 Count of Second Highest 6
Ext Order Status Shown
0/1...

Page 172

Information Elements
4-66Issue 6  June 1997 
Status Bits:When the In-use, Idle, Maintenance-busy, and 
Other-unavailable status bits are set to 1, a 
binary-encoded count corresponding to that 
status follows.
Counts:Bytes containing counts correlate with the 
status bits: The first count byte conveys the 
count for the highest order status bit set to 1. 
Typically, this is the “In-use” count, but it could 
be the idle count (for example). Later bytes 
convey the counts for the next highest order 
status...

Page 173

Codeset 6 Information Elements
Issue 6  June 1997
4-67
Service Circuit
The Service Circuit IE shown in Figure 4-36 specifies service circuit(s) to be used 
for a given call.
Figure 4-36. Service Circuit Information Element8  7654321
Service circuit
0  1001110Byte 1
Information element identifier
Length of service circuit contents 2
1
Service Circuit Type 3
Ext
Service CircuitBit
Type:7 6 5 4 3 2 1
0 0 0 0 0 0 0 Reserved
0 0 0 0 0 0 1 Call Classifier 

Page 174

Information Elements
4-68Issue 6  June 1997 
Specific Event
The Specific Event IE shown in Figure 4-37 specifies the call feedback event that 
has occurred. It also carries call state information when used in a query response.
Figure 4-37. Specific Event Identifier Information Element8  7654321
Specific Event
0  1000111Byte 1
Information element identifier
Length of Specific Event contents 2
1
Event Values 3
Ext 

Page 175

Codeset 6 Information Elements
Issue 6  June 1997
4-69
ASAI EventBits
values:7 6 5 4 3 2 1
0 0 0 0 0 0 0 Reserved
0 0 0 0 0 0 1 Alerting Event/Alerting Call State
0 0 0 0 0 1 0 Cut-through/Progress
0 0 0 0 0 1 1 Reserved
0 0 0 0 1 0 0 Disconnected/Dropped
0 0 0 0 1 0 1 Reserved
0 0 0 0 1 1 0 Hold Event/Held Call State
0 0 0 0 1 1 1 Queued
0 0 0 1 0 0 0 Busy/Unavailable
0 0 0 1 0 0 1 Reserved
0 0 0 1 0 1 0 Reserved
0 0 0 1 0 1 1 Connected Event/Connected Call State
0 0 0 1 1 0 0 Reorder/Denial
0 0 0 1 1 0...

Page 176

Information Elements
4-70Issue 6  June 1997 
Status
The Status IE:
nSupplies information for activating/deactivating Message Waiting Lamps
nReturns the status of the Message Waiting Lamp and messaging services 
supported by the ECS
nReturns the ON/OFF status of other ECS features such as Send-All-Calls 
and Call Forwarding
Figure 4-38 shows the format of the Status information element.
Figure 4-38. Status Information Element
Type of Status (byte 3, bit 7-1)
ON/OFF or ASAI (byte 4, bit 5) 
In all Set...

Page 177

Codeset 6 Information Elements
Issue 6  June 1997
4-71
to ascertain whether the MWL is on or off. If the result of the OR is a 1, then the 
MWL is on.
LWC (byte 4, bit 4) This bit is set only in the response for the Station Message 
Waiting Status Query.
PMS (byte 4, bit 3) This bit is set only in the response for the Station Message 
Waiting Status Query.
AUDIX (byte 4, bit 2) This bit is set only in the response for the Station Message 
Waiting Status Query.
AP/MCS (byte 4, bit 1) This bit is set only...

Page 178

Information Elements
4-72Issue 6  June 1997 
Trunk Group Identification
The Trunk Group Identification IE shown in Figure 4-39 identifies a specific trunk 
group and trunk within the group.
Figure 4-39. Trunk Identifier Information Elements8 7654321
Trunk Identification
0 0001010Byte1
Information element identifier
Length of contents 2
1Direction000
3
Spare
0/1 Trunk Group Number 4
Ext Spare 4a
0/1 Trunk Member Number 5
Ext Spare 5a
Direction (byte 3,Bits
bits 7 through 4)7 6 5 4
0 0 0 0 No direction
0 0...

Page 179

Codeset 6 Information Elements
Issue 6  June 1997
4-73
Trunk Group 
Number 
(bytes 4, 4a)Contains a binary coding of the trunk group 
number with bit 7 of byte 4 being the highest 
order bit. Refer to the
 DEFINITY Enterprise 
Communications Server Feature Description,
 
555-230-301, for specifics on the ECS running 
ASAI to determine the maximum values for the 
parameters encoded in the Value field.   
This determines the maximum number of bytes 
used to encode the information. This number 
varies from...

Page 180

Information Elements
4-74Issue 6  June 1997 
Trunk Group/Trunk Status
The Trunk Group/Trunk Status IE shown in Figure 4-40 conveys information 
about the busy/idle status of trunks at an ECS.
Figure 4-40. Trunk Group/Trunk Status Information Element87 6 5 4 321
Trunk Group/Trunk Status
00 0 0 1 011Byte1
Information element identifier
Length of contents 2
1 In Idle Maint Other Trans Spare 3
Ext Use Busy Unavail
0/1 Count of Highest 4
Ext Order Status Shown
0/1 Count of Second Highest 5
Ext Order Status...
Start reading Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

All Lucent Technologies manuals