Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 81
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 59 Connect Data Modules 4 The current transmission speed appears: SPEED = 56KBPS? (the d efault) or SPEED = 64KBPS? 3. To keep the existing sp eed , p ress the ENTER/YES button. 4. To c hange the existing speed , p ress NEXT/NO . When the SPEED -> NewSpeed? prompt appears, press the ENTER/YES button. 5. The CONTINUE? prompt appears. Press the...
Page 82
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 60 Connect Data Modules 4 8. When SAVE CHANGES? app ears, press the ENTER/YES button again. CHANGES SAVED ap pears, and the d ata mod ule returns to the HOME sc reen. Setting other data options for the 7400C You c an usually use the default setting s for all other op tions. However, two exc ep tions are d isc ussed below. Selecting data inversion for...
Page 83
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 61 Connect Data Modules 4 Configuring the 7400D Data Module The 7400D d ata mod ule is a c onverted 7400A used for sync hronous data transmission (Fi g u re 1 6 ). It is a direct replac ement for the MPDM. You configure the 7400D just as you would a 7400A, exc ep t that there is no SET INTERFACE op tion (the 7400D is an answer-only d evic e that c annot...
Page 84
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 62 Connect Data Modules 4 Figure 16. 7400D Data Module Accessing the menus of the 7400D You c onfig ure the 7400D from a set of menus. 1. To ac c ess the menus, p ress the NEXT/NO b utton. 2. When the SET OPTIONS? p romp t ap p ears on the LCD. Press the NEXT/ NO b utton. 00—0 0 0 —— DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the...
Page 85
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 63 Connect Data Modules 4 3. The VIEW OPTIONS? prompt appears. Press the NEXT/NO b utton. Setting speed options for the 7400D The d ata speed d ep end s on the exac t ap p lic ation, b ut most req uire 9600 b p s or, less c ommonly, 19200. 1. Press the NEXT/NO b utton to c ontinue with the setup p roc ed ure. 2. The SET OPTIONS? p rompt ap p ears on the...
Page 86
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 64 Connect Data Modules 4 4. Press the NEXT/NO b utton until you see the yourSpeed=ON? p romp t. Then press the ENTER/YES b utton. 5. If the CONTINUE? p romp t ap pears, p ress the ENTER/YES b utton. Setting the automatic-answer feature on the 7400D You c an set up the 7400A d ata mod ule to automatic ally answer c alls or you c an have it ig nore c alls...
Page 87
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 65 Connect Data Modules 4 1. When the SET CI LEAD? promp t ap p ears, p ress the ENTER/YES b utton. 2. Press the NEXT/NO button until you see the CI = correctSetting? or CI -> correctSetting? p romp t. Then p ress the ENTER/YES b utton. 3. When the CONTINUE? prompt appears, press the ENTER/YES b utton. 4. When the SET CH LEAD? p romp t app ears,...
Page 88
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 66 Connect Data Modules 4 7. When the SET CTS LEAD? prompt appears, press the ENTER/YES b utton. 8. Press the NEXT/NO b utton until you see the CTS = correctValue? or CTS -> correctValue? p rompt. Then p ress the ENTER/YES b utton. 9. When the CONTINUE? prompt appears, press the ENTER/YES b utton. 10. When the SET DCD LEAD? p romp t ap pears, p...
Page 89
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 67 Connect Data Modules 4 13. When the SET DSR LEAD? p rompt ap p ears, p ress the ENTER/YES b utton. 14. Press the NEXT/NO b utton until you see the DSR = correctValue? or DSR -> correctValue? p romp t. Then p ress the ENTER/YES b utton. 15. When the CONTINUE? prompt appears, press the ENTER/YES b utton. 16. When the SET DTR DETECT? promp t ap p...
Page 90
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 68 Connect Data Modules 4 19. When you see the SET DTR LEAD? p romp t, p ress the ENTER/YES b utton. 20. Press the NEXT/NO b utton until the DTR = correctValue? or DTR - > correctValue? prompt appears. Then press the ENTER/YES b utton. 21. When the CONTINUE? prompt appears, press the ENTER/YES b utton. 22. When the SET LL LEAD? p rompt ap p ears, p...