Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 131

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY LAN Gateway System 
109 Connecting a PC 
7
4. If you are not installing  a p rinter, set the terminal op tions ac c ording  to the 
instruc tions in the terminal doc umentation.
5. At the terminal, enter AT
. 
If the 7400B d ata mod ule is c onnec ted  
c orrec tly, it resp ond s with OK
 (written on the terminal sc reen).
6. Enter AT D T
 and  the telep hone number of the 7400A d ata mod ule 
c...

Page 132

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DEFINITY LAN Gateway System 
110 Installing a Printer 
7
9. If the PC d oes not disp lay the login
 p romp t, write d own the state 
d isp layed , then see the troub leshooting  proc edures for terminal 
c onnec tions in DEFINITY Communic ations System Generic  3 Installation, 
Ad ministration and Maintenanc e of CallVisor ASAI over the DEFINITY LAN 
Gateway.
Installing a Printer
The following instruc...

Page 133

DCS Connections 
111  
8
DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
8
DCS Connections
Typ ic ally, c ab inets are c onnec ted  b y d istrib uted  c ommunic ation-system (DCS) 
links using  d irec t c onnec tions or mod ems. 
The system uses the  p roc essor interfac e as the c ontrol c irc uit p ac k. The c ontrol 
c irc uit p ac k provid es a sing le EIA p ort that allows ac c ess to one d ata link. 
Connec tions to the system vary d ep end ing...

Page 134

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DCS Connections 
112  
8 

Page 135

DS1/T1 CPE Loopback Jack 
113 Installing Loopback Jacks 
9
DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
9
DS1/T1 CPE Loopback Jack
This c hap ter provid es information on how to install and  use a DS1 loop b ac k jac k 
to test the DS1 sp an b etween the DEFINITY and  the network interfac e p oint. The 
loop b ac k jac k is req uired  when DC p ower is at the interfac e to the ICSU. 
NOTE:
Do not remove the loop b ac k jac k after installation. It...

Page 136

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
114 Installing Loopback Jacks 
9
If there is no extend ed  demarc ation p oint, install the loop b ac k jac k direc tly at the 
network interfac e p oint as shown in Fi g u re  3 4
.
If there is an extended  d emarc ation p oint and  the smart jac k is not ac c essib le, 
install the loop b ac k jac k as shown in Fi g u re  3 5
.
If there is an extend ed  d emarc ation p oint, b...

Page 137

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
115 Administering the Loopback Jack 
9
Administering the Loopback Jack
1. At the management terminal, enter change DS1 location. 
Location is the DS1 interfac e c irc uit p ac k c orresp ond ing  to the loop bac k 
jac k.
2. Be sure the near-end CSU
 typ e is set to integrated
.
3. On p ag e 2 of the form, c hang e the supply CPE loopback jack power 
field
 to y
. 
Setting  this...

Page 138

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
116 Loopback Testing with a Smart Jack 
9
Checking the integrity of local equipment
Before you g o any further, make sure that the the p roblem is ac tually on the DS1 
sp an b y testing  the eq uip ment that c onnec ts to the sp an at the near end . 
1. Test the DS1 c irc uit p ac k, and  p erform any need ed  maintenanc e or 
rep airs. 
2. Test the ICSU, and  p erform any need...

Page 139

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
117 Loopback Testing with a Smart Jack 
9
2. If FAIL
 ap p ears on the terminal d isp lay, there may b e a fault in the wiring  
b etween the ICSU and  the loop b ac k jac k or the loop b ac k jac k may itself 
be faulty. Isolate the problem by replacing the loopback jack and 
repeating step 1
. 
3. If FAIL
 still ap p ears after the loop b ac k jac k has b een rep lac ed, susp ec...

Page 140

DEFINITY ECS Release 8.2
Installation for Adjuncts and Peripherals  555-233-116  Issue 1
April 2000
DS1/T1 CPE Loopback Jack 
118 Loopback Testing with a Smart Jack 
9
3. Once you are fairly c ertain that the test is reporting no errors (after at least 
1 error-free minute), c onfirm that the 3-in-24 p attern error d etec tor is 
op erating . Enter 
test DS1-loop 
UUCSS inject-single-bit-error
. 
where 
UU is the c abinet numb er, C is the  c arrier number, and  SS is the 
slot number of the DS1 b oard...